Mircom TX3-TOUCH-S15-E 15 Inch Surface Mount Touch Screen User Guide
- June 12, 2024
- Mircom
Table of Contents
- Mount the Enclosure
- AC Door Strike or Maglock 18 AWG
- Auxiliary Door (Output 2)
- DC Door Strike (Output 1)
- DIP Switch Settings for RS-485 Address
- Postal Lock (Input 1)
- Phone Lines
- Camera Supply
- RS-485
- Ground and Power
- Mount the TX3-PS24-5A 24 VDC, 156 W Power Supply
- Mount the TX3-PS24-5A 24 VDC, 156 W Power Supply
- Connect the Power
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Mircom TX3-TOUCH-S15-E 15 Inch Surface Mount Touch Screen
Mount the Enclosure
The enclosure mounts on the wall. Mount the enclosure right-side up (the Mircom logo on the door is in the lower right corner).
You need:
4 fasteners appropriate for the wall that you are mounting the enclosure on.
- Find a suitable location for the enclosure.
- Mark the back mounting locations of the two top screws. Ensure that at least one screw is over a wall stud.
- Place the fasteners halfway into the wall in the two top keyhole locations and wall stud.
- Place the enclosure onto the fasteners, then lower it so that the fasteners fi t in the narrow part of the keyholes.
- Screw the other fasteners into the remaining holes.
- Tighten all fasteners into place.
Installation Prerequisites
- Verify that the building telephone infrastructure is operational. When wiring an NSL installation it may be necessary to check each resident’s line.
- Ensure there is a provision for a ground circuit. The Telephone Access System assembly must be grounded by a qualified electrician. An improperly grounded unit can result in equipment malfunction and void the warranty.
- Use the latest Telephone Access System controller firmware. Mircom periodically updates panel firmware and Configurator Software to add features and correct any minor inconsistencies. For information about the latest firmware or software visit the ‘Manuals and Downloads’ section of the Mircom website at www.mircom.com
Warning: Turn the power off before wiring.
Install all power supplies outside the enclosure.
Wiring Requirements
Unless specified otherwise, all wiring is a maximum length of 1000 ft (304.8 m).
RS-485: Maximum total length: 4000 ft (1219.2 m) Use twisted shielded pair.
Door Strike : The door strike power supply depends on the door strike power requirements.
Maximum Power Supply Wire Distances
Gauge | Distance |
---|---|
16 | 125 ft (38.1 m) |
14 | 200 ft (60.96 m) |
12 | 320 ft (97.536 m) |
10 | 500 ft (152.4 m) |
AC Door Strike or Maglock 18 AWG
For a door strike: connect the jumper wire to the top pin of jumper JW8 (normally open).
For a maglock: connect the jumper wire to the bottom pin of jumper JW8 (normally closed).
Auxiliary Door (Output 2)
18 AWG
Outputs 2-4
DC Door Strike (Output 1)
18 AWG
The maximum supply for the AC or DC Power Supply for Door Strike must not exceed:
28 VAC / 1 A max
30 VDC / 1 A max
Alternative Wiring for Dry Contact
Jumper JW8 controls whether the contact is normally open or normally closed.
DIP Switch Settings for RS-485 Address
Each Touch Screen must have a unique RS-485 address.
Use DIP switches 1-6 to set the RS-485 network address. See LT-969 for details.
Leave DIP switch 7 on.
Warning: Turn the power off before wiring.
Postal Lock (Input 1)
Fire Alarm Override (Input 2) Door Contact (Input 3) 22 AWG
Warning: Do not attach the wiring until after the postal lock is installed.
Activation of this input relocks the main door (Output 1).
Activation of this input unlocks the main and auxiliary doors (Outputs 1 and 2).
For more details, see LT-996 and LT-969 on the Mircom website and the USB flash. Mircom technical support: 1-888-647-2665
Phone Lines
Line 1
Non-configurable PBX systems are not supported. For more information, contact Mircom technical support at 1- 888-647-2665.
Camera Supply
Note: Do not use for any other purpose
Camera Power Supply (12 VDC)
RS-485
Maximum total length: 4000 ft (1219.2 m) for 22 AWG Use twisted shielded pair.
See LT-996 for complete details.
Ground and Power
Mount the TX3-PS24-5A 24 VDC, 156 W Power Supply
To surface mount the power supply enclosure: You need 4 fasteners appropriate for the wall that you are mounting the enclosure on.
- Find a suitable location for the power supply enclosure, such as over a wall stud.
- Using the enclosure as a template, mark the two top mounting hole locations. Ensure that at least one side is over a wall stud.
- Remove the enclosure and place two wall fasteners halfway into the marked hole locations.
- Place the enclosure onto the fasteners and lower it so that the fasteners fi t in the narrow part of the keyholes.
- Screw the other two fasteners into the two remaining holes.
- Tighten all four fasteners into place.
Mount the TX3-PS24-5A 24 VDC, 156 W Power Supply
To surface mount the power supply enclosure:
You need 4 fasteners appropriate for the wall that you are mounting the enclosure on.
- Find a suitable location for the power supply enclosure, such as over a wall stud.
- Using the enclosure as a template, mark the two top mounting hole locations. Ensure that at least one side is over a wall stud.
- Remove the enclosure and place two wall fasteners halfway into the marked hole locations.
- Place the enclosure onto the fasteners and lower it so that the fasteners fi t in the narrow part of the keyholes.
- Screw the other two fasteners into the two remaining holes.
- Tighten all four fasteners into place.
Note: The enclosure can also be mounted directly onto the drywall using anchors.
Connect the Power
- Set the voltage selectable switch on the power supply to the appropriate voltage. The voltage selectable switch can be set to either 115 V or 230 V.
- Connect the load power supply wires to the Touch Screen terminal screws as shown in step 10.
- Connect the other end of the load power supply wires the Load terminals.
- Connect the building power supply wires to the Line terminals as shown below.
- Turn the power on by pressing the power button.
To building
WARNING
To ensure the security of occupants, change the level 3 passcode from its
default setting. See LT-995 on mircom.com for details.
Customer Support
© Mircom 2023
Printed in Canada
Subject to change without prior notice
LT-6207 rev 1
Mircom
http://www.mircom.com
CANADA – Main Office
25 Interchange Way
Vaughan, ON L4K 5W3
Tel: 888-660-4655
905-660-4655 U.S.A
4575 Witmer Industrial Estates
Niagara Falls, NY 14305
Tel: 888-660-4655
TECHNICAL SUPPORT
Tel: 1-888-647-2665
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>