To all residents of the European Union Important environmental information about this product This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to a specialized company for recycling. This device should be returned to your distributor or to a local recycling service. Respect the local environmental rules. If in doubt, contact your local waste disposal authorities. Thank you for choosing Perel! Please read the manual thoroughly before bringing this device into service. If the device was damaged in transit, do not install or use it and contact your dealer.

Safety Instructions

  • This device can be used by children aged from 8 years and above, and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the device in a safe way and understand the hazards involved. Children shall not play with the device. Cleaning and user maintenance shall not be made by children without supervision.
  • Indoor use only. Keep this device away from rain, moisture, splashing and dripping liquids.
  • Risk of electroshock when opening the cover. Touching live wires can cause life-threatening electroshocks.
  • Familiarise yourself with the functions of the device before actually using it.
  • All modifications of the device are forbidden for safety reasons. Damage caused by user modifications to the device is not covered by the warranty.
  • Damage caused by disregard of certain guidelines in this manual is not covered by the warranty and the dealer will not accept responsibility for any ensuing defects or problems.
  • Keep this manual for future reference.
  • Refer to the Velleman® Service and Quality Warranty on www.velleman.eu.

Overview

  1. M button
  2. antenna
  3. GSM status LED
  4. power LED
  5. SIM card slot
  6. USB connector (firmware upgrade only)
  7. temperature sensor slot

GSM status LED:

  • Slow blinking: no GSM signal
  • Normal blinking: GSM signal fixed
  • Fast blinking: send or receive SMS

Power Control Connector

velleman-E300GSM-GSM-Phone-Remote-Control-Module-fig-1

  • Input: 110-230 V~
  • L: live
  • N: negative
  • G: ground
  • Output: 110-230 V~
  • L: live
  • N: negative
  • G: groundvelleman-E300GSM-GSM-Phone-Remote-Control-Module-fig-2
  • 12V: output and alarm sensor input
  • 12V: constant 12 VDC output (max. 200 mA)
  • S1: wired sensor input 1, NO/NC type
  • S2: wired sensor input 2, NO/NC type
  • 12V(C): controllable 12 VDC output (max. 200 mA) (only via SMS)

Start

  • Connect the antenna to the power control.
  • Deactivate the SIM card’s PIN code using your cell phone.
  • Install your SIM card (standard format). Make sure to insert it fully into the slot.
  • Connect the temperature sensor if desired.
  • Connect the power input and output. Make sure to cut off the power supply prior to connecting!
  • Reconnect the power. The LED will light within 3 to 5 seconds.

Registering a Phone Number

This power control accepts up to five phone numbers, i.e. one master number and four auxiliary numbers. The master number has full authorization to configure the devices. The auxiliary numbers can only be added by the master number. All configurations are processed by sending an SMS to the device’s SIM card. The SMS format is #code-1#code-2#.

  • Register the master number: #00#
  • Add an auxiliary number: #06#User-number#
  • Delete an auxiliary number: #15#User-number#

Manually reset the device to delete the old master number if the device replies [Master number already exists]. Hold the M button pressed for ten seconds to return to the factory settings.

Free-Calling Control

A master or auxiliary number calling the SIM card number is able to switch the 230 V power on or off for a few seconds. Call to switch on/off the power output: #09#1#

  • When a user is calling, the switched on power will switch off and vice versa.

Call to switch on/off the power output for a few seconds: #09#2#time#

  • Time parameters: 1-1800, i.e. duration 1-1800 seconds. Switch off calling control function: #09#0#

Power On/Off

Any registered user can send an SMS to switch the 230 V power on/off.

  • Switch on power: #01#0#
  • Switch off power: #02#0#

Delay Control
Automatically switch the 230 V power on/off for a few minutes. Valid only for the master number.

  • Switch on power for a few minutes: #12#0#time#0#
  • Switch off power for a few minutes: #12#0#time#1#
  • Time range: 1-720, i.e. duration 1-720 minutes.

Manually switch on/off the device to abort this function automatically.

Schedule Control

Automatically switch the 230 V power on/off according to the set schedule. Valid only for the master number.

Set switch-on schedule: #20#0#day#start-time#end-time#

  • It will switch on the power at set time.
  • Day: one digit, see table.
value day   value day
0 Every day   5 Friday
1 Monday   6 Saturday
2 Tuesday   7 Sunday
3 Wednesday   8 Monday-Friday
4 Thursday   9 Weekend
  • Start-time and end-time: four digits (hhmm) in 24h-format.
  • Example: #20#0#0#2000#0800# means every day, power on at 20:00, power off at 08:00 the next day.

Activate schedule control function: #19#0#1# Manually switch on/off the device to abort this function automatically.

Temperature Control

Connect the included temperature sensor. The temperature will be displayed in an SMS. The temperature control function is useful when the power output is connected to a heating or cooling device. The power will automatically switch on/off according to temperature changes.

Set control parameters: #24#0#mode#low-temp#high-temp#

  • Mode parameters: 1 (warming) or 2 (cooling).
  • Temperature range: -30 °C to 100 °C.
  • Example: #24#0#1#15#25# means power on when temperature < 15 °C, power off when temperature > 25 °C.

Activate temperature control function: #23#0#1#

Manually switch on/off the device to abort this function automatically.

Temperature Alarm

Connect the included temperature sensor. You will be notified by SMS when the temperature is out of range. Set alarm range: #22#0#low-temp#high-temp#

  • Temperature range: -30 °C to 100 °C.
  • Activate temperature alarm: #21#0#1#
  • Deactivate temperature alarm: #21#0#0#

Wired Sensor Alarm

The power control accepts two wired sensor inputs, one constant 12 VDC output and one controllable 12 VDC output. The constant 12 VDC output can act as a power supply for the wired sensors. The input sensors are of the NO/NC type. Connect the wired sensors and COM PIN to the S1 and S2 terminals. Do not connect S1 and S2 to the power supply as this can irreversibly damage the device. The power control will send an SMS when the sensor is triggered.

  • SMS when sensor alarm on: #40#1#

  • SMS when sensor alarm off: #40#0#

  • Change sensor name: #43#sensor-1#sensor-2#

  • Example: #43#door#window# means door = sensor 1, window = sensor 2. The respective name will appear in the SMS.
    Change alarm mode: #44#sensor-number#mode#

  • Sensor number: 1 or 2. Mode: 1, 2 or 3. Mode 1: NC (only alarm when two terminals are open), mode 2: NO (only alarm when two terminals are closed), mode 3: NO/NC (only alarm when two terminals are open or closed).

Auto Control When Triggered

Use this function as a smart control for your home, e.g. as motion detector. Sensor trigger, auto turn on 230 V power: #42#220#time#

  • Time range: 1-1800, i.e. turn on power for 1-1800 seconds. Function turn off at set time 0 (default value).
    • Sensor trigger, auto turn on 12 VDC power: #42#12#time#
  • Time range: 1-1800, i.e. turn on power for 1-1800 seconds. Function turn off at set time 0 (default value = 60).

A triggered sensor can switch on 230 V and 12 VDC according to the settings.

Advanced Settings

SMS when on/off button pressed
Default send SMS when M button is pressed.

  • SMS when on-off button pressed on: #03#1#
  • SMS when on-off button pressed off: #03#0#

SMS when power lost or restore
Default send SMS when main power supply is lost or restored.

  • SMS when power lost or restored on: #05#1#
  • SMS when power lost or restored off: #05#0#

SMS when calling operation

  • Default send SMS when calling.
  • SMS when calling on: #41#1#
  • SMS when calling off (default): #41#0#

Reset factory settings

  • There are two methods to restore the factory settings:
  • Method 1: The master uses sends an SMS.
  • Reset factory settings: #08#1234# Method 2: Hold the M button pressed for ten seconds. The factory settings are re-loaded after the beep.

SMS Command-List

category function command


Define users

| Register master number| #00#
Add family number| #06#family-number#
Check family number| #06#
Delete family number| #15#family-number#
Delete all family numbers| #15##




Power control

| Set calling to switch power| #09#1#
Set calling to switch on power for some seconds| #09#2#time#
Switch off calling function| #09#2#
Power on| #01#0#
Power off| #02#0#


Delay control

| Turn off power for some minutes| #12#0#minutes#1#
Turn on power for some minutes| #12#0#minutes#0#


Schedule control

| Schedule control on| #19#0#1#
Set schedule control parameters| #20#0#workday# starttime#endtime#


Temp control

| Temp control on| #23#0#1#


Set temp control parameters

| #24#0#mode#

low-temp#high-temp# warming=1, cooling=2


Temp alarm

| Temp alarm on| #23#0#1#
Set temp range| #22#0#mintemp#maxtemp#
Temp alarm off (default)| #21#0#1#



Sensor alarm

| Sensor alarm on| #40#1#
Sensor alarm off| #40#0#
Change sensor name| #43#sensor1#sensor2#
Change alarm mode| #44#sensor-number#mode#


Sensor trigger, turn on power

| Sensor trigger, auto turn on 230 V power| #42#220#time#
Sensor trigger, auto turn on 12 VDC power| #42#12#time#







SMS notifications

| SMS when on-off button pressed on (default)| #03#1#
SMS when on-off button pressed off| #03#0#
SMS when power lost or restore on (default)| #05#1#
SMS when power lost or restore off| #05#0#
SMS when calling on| #41#1#
SMS when calling off (default)| #41#0#
SMS to users on (default)| #16#1#
SMS to users off| #16#0#






Check status

| Check status| #07#
Check delay control status| #34#
Check schedule control status| #33#
Check temp control status| #32#
Check temp alarm status| #35#
Check GSM signal| #27#
GSM signal alert on| #27#1#
GSM signal alert off (default)| #27#0#
Reset| Reset factory setting| #08#1234#

Cleaning and Maintenance

Occasionally wipe it with a damp cloth occasionally to keep it looking new. Do not use harsh chemicals, cleaning solvents or strong detergents.

Technical Specifications

  • max. power loading ………………………… 3500 W, 16 A (two lines control)
  • power input ……………………………………………….. 110-230 V~, 50/60 Hz
  • power output ………………. 110-230 V~, 50/60 Hz, 12 VDC (max. 200 mA)
  • GSM frequency ……………………………………….. 850/900/1800/1900 MHz
  • SIM card slot ………………………………………………standard size SIM card
  • wired sensor input ………………… NO (normal closed) or NC (normal open)
  • wired sensor cable length ………………………………………… 2 m (included)
  • GSM antenna ……………………………………………………………….. included
  • dimensions …………………………. 90 x 70 x 73 mm (without GSM antenna)
  • weight ……………………………………………………………………………222 g
  • max. users ………………………………………………… 5 (1 master / 4 users)

Use this device with original accessories only. Velleman nv cannot be held responsible in the event of damage or injury resulting from (incorrect) use of this device. For more info concerning this product and the latest version of this manual, please visit our website www.perel.eu. The information in this manual is subject to change without prior notice.

RED Declaration of Conformity Hereby, Velleman NV declares that the radio equipment type [E300GSM] is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.velleman.eu.

COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise without the prior written consent of the copyright holder.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals