InnovaSpa X251161 Drain Valve
Product Information
- Product Name: Draining Valve Replacement Kit
- Model Number: N/A
- Manufacturer: N/A
- Part Number: 300-0233
- Glue Brand: PVC 747 Weld-ON Glue
- Glue Sizes:
- 118 ml (Part #112-W12725WEL)
- 237 ml (Part #105-0508)
- Cutter Type:
- Utility Knife (Box Cutter) (Part #137-HD-PVC-CUTTER2CE)
- Pipe Cutter (Part #137-HOSECUTTERSCEN)
Product Usage Instructions
- Empty the spa of its water.
- Locate the draining valve by following these steps:
- Open the panel under the keypad.
- Open the Thermofoil and find the drainage hose (identified with a green sticker).
- Pull out the drainage hose from the spa.
- Connect the adapter to the draining valve by applying glue to both surfaces. Please note:
- The adapter has two different diameters. The larger one connects to the draining valve, and the smaller one connects to the drainage hose.
- Using the cutter, cut the drainage hose near the draining valve. Ensure that the drainage hose is free of water.
- Attach the drain assembly to the drainage hose using glue.
- Allow 24 hours for the glue to dry before filling the spa. The glue bonds at temperatures of 15 degrees Celsius and above.
- Close the Thermofoil tightly with adhesive tape.
If you have any questions, please contact our service department by phone at 1-866-995-8646, extension 226 or 227.
YOU WILL NEED
- 1 drain assembly (Part # 300-0233)
- PVC 747 Weld-ON Glue (118 ml #112-W12725WEL or 237 ml #105-0508)
- 1 utility knife (box cutter) or pipe cutter (Part # 137-HD-PVC-CUTTER2CE or 137-HOSECUTTERSCEN)
FIRST STEP
- Empty the spa of its water.
- Find the draining valve.
- Open the panel under the keypad
- Open the Thermofoil and find the drainage hose (identified with a green sticker)
- Pull out the drainage hose from the spa
SERVICE CALL
DRAINING VALVE REPLACEMENT JUNE 2022
SECOND STEP
REPAIR
- Connect the adapter to the draining valve by applying glue to both surfaces.
- NOTE : The adapter has two different diameters. The larger one connects to the draining valve and the smaller one to the drainage hose.
- With the cutter, cut the drainage hose near the draining valve
- Make sure the drainage hose is free of water
- Attach the assembly to the drainage hose with glue
- Allow 24 hours to dry before filling the spa. The glue bonds at temperatures of 15 degrees and above.
- Close the Thermofoil tightly with adhesive tape