SOLAX POWER X-Hybrid G4 Hybrid Inverter Installation Guide
- June 10, 2024
- SOLAX POWER
Table of Contents
X-Hybrid G4 Hybrid Inverter
Installation Guide
X-Hybrid G4 Hybrid Inverter
| D version| M version
---|---|---
Product Image| |
Applicable scene 1| 1. Office areas, where data storage is important.
2. To protect the electrical appliances whose sudden power failure causes
damage.
Reason: With UPS switching function, the off-grid switching time is less
than 20mS, and it can switch off-grid operation without interruption, meaning
that electrical appliances will not be powered off.|
Household use.
Integrated installation, beautiful, no external wiring, and the
installation area is small, installation in the house saves space, neat and fresh.
Applicable scene 2| | Suitable for the areas where the local installer‘s labor
costs are
high, because installation for this version is easier and faster.
Applicable scene 3| |
Full loads needed for most time.
The full load function allows you to use all electrical appliances in your home at will in the event of a power outage.
Installation method
In this solution, the Matebox contains all the accessories of the inverter
system, including DC and BAT switch, CT and RCD, assembles all accessories and
cables in advance, omitting complicated installation steps and saving time and
money.
All wirings are operated inside the box and cabinet, and the appearance of the
entire system will be clean and tidy.
X1-MATEBOX
One Matebox contains:
DPDT Devices | CT | Circuit Breaker | RCD | DC switch |
---|
Model distinction
D version
- X1-Hybrid-3.0-D
- X1-Hybrid-5.0-D
- X1-Hybrid-7.5-D
- X1-Hybrid-3.7-D
- X1-Hybrid-6.0-D
M version
- X1-Hybrid-3.0-M
- X1-Hybrid-5.0-M
- X1-Hybrid-7.5-M
- X1-Hybrid-3.7-M
- X1-Hybrid-6.0-M
-
According to power:
3.0kW, 3.7kW, 5.0kW, 6.0kW, 7.5kW; -
According to DC Switch:
D: Built-in DC Switch, M: External DC Switch; -
According to full load function during off-grid:
D: Without Matebox (back up loads);
M: With Matebox (all loads);
Full load function
D version | M version |
---|
Diagram A: Neutral line and PE line are separated from each other, and the
common load is connected to the off-grid port;(For most countries)| Diagram B:
Neutral line and PE line are separated from each other, all loads connect to
the Off-grid port;(For most countries)
|
Diagram C: Neutral line and PE line are combined together, and the common load
is connected to the off-grid port(Apply to Australia)| Diagram D: Neutral line
and PE line are combined together, all loads connect to the Off-grid
port(Apply to Australia)
|
Full load function advantage:
In the event of power failure, the emergency power supply can be used for all
loads in the house. When installing D version, we need to be divide loads into
common and back up loads.
Accessories distinction
D version
Optional accessories
Meter: Solax Single-phase electric meter;
Monitoring: Pocket WiFi Plus, Pocket LAN, Pocket 4G
Standard accessories
Instrument sensor: CT (inside the inverter);
M version
Optional accessories
Meter: Solax Single-phase electric meter;
Standard accessories
Monitoring: Pocket WiFi Plus:;
Instrument sensor: CT (Included in Matebox);
Annex distinction
D version
Expansion bolt/screw/washer3, European terminal1, waterproof RJ45 plug3,
manual/quick installation guide1, PV connection terminal2 pairs, PV pin
terminal4, battery connection terminal1 pair, communication R type terminal
1
M version
Expansion bolt/screw/washer3, European terminal1, communication waterproof RJ45 crystal plug2, manual/quick installation guide1
D/M use the same packaging carton
1 carton difference
D version
In version D, the carton will be marked with “√” as D, and the fifth digit of
the SN is “D”.
M version
In the M version, M will be marked with a “√” on the carton, and the fifth
digit of the SN is “M”.
2 carton difference
| D version| M version
---|---|---
Product Image| |
Applicable scene 1| 1. Office areas, where data storage is important.
2. To protect the electrical appliances whose sudden power failure causes
damage.
Reason: With UPS switching function, the off-grid switching time is less than
20mSand it can switch off-grid operation without interruption, meaning that
electrical appliances will not be powered off.|
Household use.
Integrated installation, beautiful, no external wiring, and the installation area is small, installation in the house saves space, neat and fresh.
Applicable scene 2| | Suitable for the areas where the local installer‘s labor
costs are high, because installation for this version is easier and faster.
Applicable scene 3| |
Full loads needed for most time.
The full load function allows you to use all electrical appliances in your home at will in the event of a power outage.
Installation method
Thanks to the pre-wired solution, Mate Box will assemble all accessories and
cables in advance, omitting complicated installation steps and saving time and
money.
X3-MATEBOX G1
One Matebox contains:
Circuit Breaker | RCD | DC switch |
---|
X3-MATEBOX G2
One Matebox contains:
DPDT Devices | Meter | Circuit Breaker | RCD | DC switch |
---|
Model distinction
D version M
- X3-Hybrid-5.0-D
- X3-Hybrid-8.0-D
- X3-Hybrid-12.0-D
- X3-Hybrid-6.0-D
- X3-Hybrid-10.0-D
- X3-Hybrid-15.0-D
M version
- X3-Hybrid-5.0-M
- X3-Hybrid-8.0-M
- X3-Hybrid-12.0-M
- X3-Hybrid-6.0-M
- X3-Hybrid-10.0-M
- X3-Hybrid-15.0-M
-
Divided according to power:
5.0kW, 6.0kW, 8.0kW, 10.0kW, 12.0kW, 15.0kW; -
Divided according to DC Switch:
D: Built-in DC Switch, M: External DC Switch; -
According to whether it can be divided into full load function:
D: Without Matebox (Emergency power supply load off-grid use);
M: With Matebox G1 (Integrated wiring); With Matebox G2 (All loads are used off-grid);
Full load function
D version | M G1 version | M G2 version |
---|
Diagram A: N line and PE line separate wiring, D series inverter; (For most
countries)| Diagram B: N line and PE line separate wiring, M series inverter;
(For most countries)| Diagram A: N line and PE line separate wiring, M series
inverters; (For most countries)
| |
Diagram C: N line and PE line together, D series inverter: ( Applicable to
Australia)| Diagram D: N line and PE line together, M series inverter; (
Applicable to Australia)| Diagram B: N line and PE line together, M series
inverters; ( Applicable to Australia)
| |
D version does not have full load function
M version has full load function
Full load function advantage:
In the event of a power failure, the emergency power supply of the inverter
can be used for all loads in the house. When installing the D version, it
needs to be divided into common load and ordinary load. When the power fails,
the emergency power load can enjoy the uninterrupted power supply.
Meter/CT
| | D| M basic| M high-end| remark
---|---|---|---|---|---
Standard| Meter| | | | Three phase meter is included in the high-end matebox
Optional| Battery| | | | Battery: T30, 2-4 batteries T58, 2-4 batteries
Monitoring| | | | Monitoring: Pocket WiFi Plus, Pocket LAN, Pocket 4G.
M basic can only use Pocket WiFi Plus
CT| | | | Solax CT
Meter| | | | Solax three-phase meter
Annex distinction
D version
Expansion bolt/screw/washer3, European terminal1,waterproof RJ45 plug3,
manual/quick installation guide1, PV connection terminal2 pairs, PV pin
terminal4, battery connection terminal1 pair, communication R type terminal
1
M version
Expansion bolt/screw/washer3, European terminal1, communication waterproof RJ45 crystal plug2, manual/quick installation guide1
D/M use the same packaging carton
1 carton difference
D version
In version D, the carton will be marked with “√” as D, and the fifth digit of
the SN number is “D”.
M version
In the M version, M will be marked with a “√” on the carton, and the fifth
digit of the SN number will be “M”.
2 carton difference
D version
D version has DC switch
M version
In the M version, the DC switch is externally mounted on the matebox.
Thank you!
www.solaxpower.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>