LENA LIGHTING PL-L UV-C Sterilon Max Instruction Manual

June 12, 2024
LENA LIGHTING

LENA LIGHTING PL-L UV-C Sterilon Max

LENA LIGHTING-PL-L-UV-C-Sterilon-Max

Product Information:

The UV-C Sterilon Max is a lighting fixture designed for disinfection purposes. It is equipped with PL-L 2G 11 UV-C tubes that emit ultraviolet light at a wavelength of 253.7 nm. The fixture has an IP20 protection rating and operates on a voltage range of 220-240 V at a frequency of 50-60 Hz.

Product Usage Instructions

  1. Assembly: The assembly of the UV-C Sterilon Max fixture should be carried out by a qualified person.
  2. Power On/Off: Use the switch/button labeled “B” to turn the fixture on or off.
  3. Changing a UV-C Tube:
  4. Wait for 3 minutes after turning off the lamp before opening the door.
  5. Use the key to open the 3 locks and open the door.
  6. Replace the UV-C tube with a new one. Use protective gloves when handling the UV-C tubes.
  7. Changing G2 Filter:
  8. Remove the new filter from its packaging.
  9. Replace the old filter with the new one.
  10. Safety Precautions:
    • The light source used in this fixture should only be replaced by the manufacturer or a qualified person.
    • Do not cover the lighting fitting with an insulation mat or other materials. Leave a free space of about 10 cm around the installed luminaire.

Please refer to the user manual for detailed instructions and safety information.

INSTALLATION INSTRUCTION

  • A. Flow contol
  • B. Switch on-off
  • C. Reset of UV-C fluorescent lamps
  • D. Poprawna praca UV-C
  • F. Fan failure signaling

LENA LIGHTING-PL-L-UV-C-Sterilon-Max-2

Air disinfection in progress

LENA LIGHTING-PL-L-UV-C-Sterilon-Max-3

CHANGING A UV-C TUBE

LENA LIGHTING-PL-L-UV-C-Sterilon-Max-4

CHANGING A UV-C TUBE

  • A) Wait 3 minutes after turning off the lamp before opening the door
  • B) Use the key to open the 3 locks and open the door

LENA LIGHTING-PL-L-UV-C-Sterilon-Max-5

CHANGING A UV-C TUBE

LENA LIGHTING-PL-L-UV-C-Sterilon-Max-6

CHANGING A UV-C TUBE

LENA LIGHTING-PL-L-UV-C-Sterilon-Max-7

CHANGING G2 FILTER

  • A) Wait 3 minutes after turning off the lamp before opening the door
  • B) Use the key to open the 3 locks and open the door

LENA LIGHTING-PL-L-UV-C-Sterilon-Max-8

CHANGING G2 FILTER

LENA LIGHTING-PL-L-UV-C-Sterilon-Max-10

CHANGING G2 FILTER

Before installing the new filter,remove it from the packaging

LENA LIGHTING-PL-L-UV-C-Sterilon-Max-9

CHANGING G2 FILTER

LENA LIGHTING-PL-L-UV-C-Sterilon-Max-10

GREEN
UP TO 8000H – OK

YELLOW
8000H – 9000H CLOSE TO END OF LIFESPAN

RED
OVER 9000H – REPLACE WITH NEW UV-C TUBES

RED BLINKING
FAULTY TUBES

RED

The light source used in this luminaire should only be replaced by the manufacturer or his maintenance representative, or a similarly qualified person.

Do not cover the lighting fitting with an insulation mat or other materials. There should be free space (about 10 cm) provided around the installed luminaire.

IMPORTANT INSTRUCTIONS FOR SAFE USE

WARNING BEFORE USING LAMP FOR THE FIRST TIME, READ THE USER MANUAL AND FOLLOW THE INSTRUCTIONS.

UV-C Sterilon MAX flow luminaires use ultraviolet light, destroy the DNA or RNA of all microorganisms exposed to the light and remove viruses, bacteria and mould from the air. The shielded UVC light does not escape to the outside of the luminaire. Thanks to stimulated circulation, the air passes through the luminaire interior, where it is exposed to the light and disinfected, and then pushed outside. Luminaires can work in the presence of people.

Way of operation

  1. Place the luminaire in a disinfected room with the door directed towards the wall.
  2. Do not cover the luminaire, do not place any objects on the luminaire. In order not to disturb circulation, leave an empty space and do not put any objects within 1 metre of the luminaire fan.
  3. There may be people in the room. They can move freely and do not need protective clothing.
  4. Do not open the luminaire covers during its operation. Except for the flap to regulate the flow. Secure the luminaire against uncontrolled opening by other people, pay special attention to children.
  5. The smell emitted by the luminaire is a technical smell. It may last for approximately 140 hours when the device is used. This smell does not pose any threat to luminaire users.
  6. A small amount of visible blue light is reflected light which does not contain UV-C radiation and is safe for people.
  7. Before opening the door, turn o the luminaire and wait 3 minutes for the fans to stop.
  8. Do not open the door while the luminaire is connected to the electricity supply.
  9. After placing the luminaire in the desired place, release the locks on the wheels.
  10. Do not lean on the luminaire or tilt it.
  11. Lock the locks and do not leave the keys in them.

Maintenance and filter replacement

UV-C Sterilon MAX luminaires are equipped with pre-filters as standard. These filters should be replaced every three months or more often, depending on how dirty the filter is.

Operational safety
The UV-C light emitted by the lamp is highly harmful to humans and other living organisms, damages eyesight, skin and cell DNA. UV-C light degrades the DNA and RNA code in the cells of living organisms. In the event of damage to the body, UV-C rays may escape, which poses a threat to people and animals. If the fluorescent lamps break, ventilate the room for 30 minutes and remove the contaminated parts, preferably with gloves. Place them in a sealed plastic bag and take to a local waste disposal facility for recycling. Do not use a vacuum cleaner to remove damaged parts.

Technical Data

  • 8x PL-L 36W, 220-240V, 50-60Hz
  • Cable 4m, 3×0,75mm
  • Protection class I

No protection against explosion.

Assembly should be carried out by a qualified person.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>