Product Usage Instructions
Modular Ceiling Only
- This product should only be installed on a modular ceiling.
Power On/Off
- To power on the device, switch it to the “ON” position.
- To power off the device, switch it to the “OFF” position.
Cable Management
- Close the cable in the cover and insert the cover properly.
Safety Fix to the Ceiling
- Hang the device in places reinforced on the ceiling.
Filter Replacement
- Depending on the room type, the filters need to be replaced after a certain period.
- For medical rooms, the HEPA/F7 filter should be changed every 30 days.
- For other rooms, the HEPA/F7 filter should be changed every 90 days.
- If there is a carbon filter, remove it, wash it, and then change the HEPA filter. Put the clean carbon filter back in place.
UV-C Tube Replacement
- When replacing UV-C tubes, use protective gloves.
- Remove the bolts using an allen key (size 2.5).
- Pull up and take off the cover to access the UV-C tubes.
- Remove the F7/HEPA/CARBON filter if present.
- Replace the UV-C tubes with new ones.
- Insert the bolts and tighten them using an allen key (size 2.5).
- Insert the cover back in place.
- If applicable, insert the F7/HEPA/CARBON filter.
Important Note
- The light source used in this luminaire should only be replaced by the manufacturer or their authorized representative.
- Do not cover the lighting fitting with an insulation mat or other materials. Provide about 10 cm of free space around the installed luminaire.
Assembly should be carried out by a qualified person
Dirtiness that settle down on the diffuser due to normal operation of the
fitting shall be cleaned with a damp cloth. Do not use abrasive cleaners.
DISPOSAL
We would like to inform you that our product’s are marked in accordance with
the European Directive 2002/96/CE and Polish Act o n used electric and
electronic equipment with a sign of a crossed-out waste container:
This mark informs abort the fact that the device, after its application use,
cannot be placed together with other types of household waste. The user is
obliged to return it to the entities conducting a collection of used electric
and electronic equipment. The collection points, including local collection
points, shops and municipal entities create a proper system making it possible
for the return of the equipment. Proper proceeding with used electric and
electronic equipment contributes to the avoidance of damaging consequences for
the health of the inhabitants and natural environment chick result form the
presence of dangerous substances and improper storage and processing of such
devices and equipment.
INSTALLATION
You need to cut a hole in the cover for the cable
Hang in places reinforced on the ceiling!
CHANGING A HEPA
CHANGING A HEPA FILTER
BLUETOOTH CONTROL
UV-C TUBES STATUS INDICATOR
The light source used in this luminaire should only be replaced by the manufacturer or his maintenance representative, or a similarly qualified person
IMPORTANT INSTRUCTIONS FOR SAFE USE
WARNING BEFORE USING LAMP FOR THE FIRST TIME, READ THE USER MANUAL AND FOLLOW THE INSTRUCTIONS. !
UV-C STERILON SQUARE HEPA 2 PP flow luminaires use ultraviolet light, destroy the DNA or RNA of all microorganisms that will be exposed, and remove viruses, bacteria and mold from the air. The shielded UVC light does not escape to the outside of the luminaire. Thanks to stimulated circulation, the air passes through the luminaire interior, where it is exposed to the light and disinfected, and then pushed outside. Luminaires can work in the presence of people.
Exposure method:
- Install the luminaire in a disinfected room, in a central place, if possible, to increase the effectiveness of disinfection. Remember that the disinfection e?ciency in a given place depends on the number of luminaires 2 3 and the area of the room. The maximum area (cubic capacity) of a disinfected room is approx. 50 m (150 m ).
- In order not to disturb air circulation, do not cover the luminaire fans.
- There may be people in the room. They can move freely and do not need protective clothing.
- Do not open the luminaire covers during its operation. Secure the luminaire against uncontrolled opening by other people
- Do not use in rooms smaller than 1 m2.
- The smell emitted by the luminaire is a technical smell. It may last for approximately 60 hours when the deviceis used. This smell does not pose any threat to luminaire users.
- A small amount of visible blue light – it is reflected light, which does not contain UV-C radiation and is safe for humans.
Operational safety
The UV-C light is highly harmful to humans and other living organisms, damages
eyesight, skin and cell DNA. UVC light degrades the DNA and RNA code in the
cells of living organisms. In the event of damage to the luminaire housing, no
people or animals should be within the range of direct UVC rays. Damage to the
luminaire will not affect your health, if basic precautions are maintained. In
this case, turn o? the lamp immediately. If the fluorescent lamps break,
ventilate the room for 30 minutes and remove the contaminated parts,
preferably with gloves. Place them in a sealed plastic bag and take to a local
waste disposal facility for recycling. Do not use avacuum cleaner to remove
damaged parts. Proper use of the luminaire does not pose any threat to life
and health.
Wymiana filtra
The lamp is equipped with a HEPA or F7 filter. The filter should be replaced with a new one every 3 months (when used 8 hours a day), or after 760 hours of continuous operation The lamp is not intended for domestic use