LOCKWOOD 3579HS Series SCEC Endorsed Electric Mortice Lock Instruction Manual

June 12, 2024
LOCKWOOD

LOCKWOOD 3579HS Series SCEC Endorsed Electric Mortice Lock

HAND OF DOOR ACCORDING TO ENGLISH PRACTICE

RIGHT – HAND DOOR LEFT – HAND DOOR

OUTS IDE DOOR OPENING IN

|

OUTSIDE DOOR OPENING OUT

|

OUTSIDE DOOR OPENING IN

|

OUTSIDE DOOR OPENING OUT

HAND OF LOCK

BOLT

  • Determine hand of lock required from above hand of door chart.
  • Rotate bolt head to suit latching direction.

LOCK STATUS

EXTERNAL OPERATION OF THIS LOCK MUST BE USED IN CONJUNCTION WITH A SECONDARY ELECTRONIC LOCKING DEVICE {eg. Electric strike).

  • The lock is set up as Fail Safe (Power to Lock).
    The lock will operate as follows:
Power l nterio r Hub/Handle Exterior Hub/Handle
Off Unlo c ked Locked
On Locked Locked

SETTING LOCK HANDING

FAIL SAFE / FAIL SECURE MODE

  • The lock is factory set to FAIL SAFE.

  • This mode does not require changing.

  • The external side of this lock will not electrically unlock.
    WARNING: Do not use a power driver to tighten screw.

  • This Lockwood 3579,HS Series Electric Mortice Lock is to be mounted in accordance with these instructions. Locks may or may not have cylinders, lever handles, turn knob or emergency button. Disregard instructions referring to the features not required.

  • Important : Before drilling door, ensure correct hand is being installed.

  • NOTE: CASE DOES NOT need to be opened, to change HAND or FUNCTION of LOCK.

  • Min. Door Gap 3mm. Max. Door Gap 6.5mm.

MONITOR SELECTION

HUB MONITOR SELECTION

  • Select normally open, normally closed, Lock Side A or Lock Side B monitoring configuration.

KEY OVERRIDE MONITOR SELECTION
Set the 2 WAY SWITCH to desired setting.

DOOR PREPARATION

  • Establish height that lockset will be mounted on door and mark centreline of door thickness on door edge.

  • Place Mortice Template on door and align centreline on template with centre line on door. Secure with sticky tape.

  • Mark and drill mortice to suit mortice lock depth (90mm).

  • Ease out mortice cavity where necessary.
    Clean out mortice before inserting lock.

  • Allow space for extra cable length behind lock for ease of maintenance.

  • Insert lock in mortice with Cover Plate on and scribe around Cover Plate for size of recess,. ensuring that no foreign matter finds it way into the lock mechanism.

  • Remove lock from mortice and chisel recess 4m m deep to receive both front and cover plate. Cover plate must be flush with edge of door.

  • Ensure lock is removed from mortice cavity. Fold template along backset fold line. Align EDGE A with bottom of cover plate recess. Establish holes required to suit lock function 1, mark hole centres accurately, drill and clean holes.

  • Drill furniture holes as required.

  • Connect power plug from lock to power supply socket and place lock in mortice and insert cylinder.

  • Fasten mortice lock into door using mounting screws provided.

LOCK WITH CYLINDERS

  • Using a small flat screwdriver, lever out Cylinder Hole Plug where fitted.
  • Secure cylinder with retainer pin, ensuring pin is flush with front plate.
  • Install cover plate and secure with 2 M4 screws to lock body.

LOCKS WITHOUT CYLINDERS

  • Connect power plug from lock to power supply socket and place lock in mortice.
  • Secure lock to door with 2 wood screws supplied.
  • Install cover plate and secure with 2 M4 screws to lock body.

FURNITURE WITH L.E.D

  • Before assembling furniture to door, connect LED cable to 3 pin socket located at TOP of lock body.

LOCKS WITH SPINDLES


IMPORTANT:
Attach spindle spring to rear of spindle before assembling

  • All locks are supplied with spindles.
  • Insert spindle(s} into lock, as required.
  • Assemble furniture as required.
  • Ensure furniture is not over-tightened.

MOUNTING STRIKE AND MAGNET

  • Mark out door frame for strike.
  • Mortice door frame for strike box and strike.
  • Bolt recess to be 15mm deep in door frame.
  • Screw strike and strike box to door frame with 2 screws supplied.
  • Drill 19mm DIA hole x 20 Deep, 62mm above strike centreline.
  • Insert magnet in hole.

ELECTRICAL SPECIFICATIONS

Note : Diagram depicts RH opened door, with handle & key in rest state.

Electrical Specifications

  • Solenoid Activation
    Operating Voltage: 12~30Vdc
    Operating Current: S00mA Max, 80mA holding @ 12Vdc 275mA Max, S0mA holding @ 24Vdc

  • Led Current
    Add 20mA to Total Operating Current if Led’s are fitted.

  • Monitoring Circuits
    Microswitches: 500mA Max @ 30Vdc each circuit
    Reed switch: 1 00mA Max @ 30Vdc COLOUR
    Black
    Red
    Yellow
    Pink
    Light Blue
    Grey
    Brown
    Blue
    Orange
    Violet
    Green
    White| FUNCTION1
    Solenoid 0V de
    Solenoid Positive ( 12~30Vdc)
    Door closed Reed Switch (NC)
    Reed Switch Common
    Deadlatched and Locked (NC)
    Deadlatched and Locked Common
    Hub monitor (NO or NC)
    Hub monitor Common
    Key override monitor (NO or NC)
    Key override monitor Common
    LED ( 12~30Vdc)
    Deadlatched and Locked centre tap
    ---|---

FOLD LINE ALONG EDGE OF DOOR 60mm BACKSET

ENSURE LOCK IS REMOVED FROM MORTICE BEFORE DRILLING HOLES
DO NOT DRILL HOLES RIGHT THROUGH DOOR TO PREVENT POSSIBLE DAMAGE TO DOOR FACE.
WARNING CARE MUST BE TAKEN WHEN DRILLING & AFFIXING SCREWS.
SCREWS MUST NOT COME IN CONTACT WITH ELECTRICAL WIRES ALLOW EXTRA CABLE LENGTH BEHIND LOCK FOR EASE OF MAINTENANCE.

ASSA ABLOY Australia Pty Limited, 235 Huntingdale Rd, Oakleigh, VIC 3166 ABN 90 086 451 907 ©2017