enbrighten 60226 In-Wall Smart Fan Control Instruction Manual

June 12, 2024
enbrighten

In-Wall Smart
Fan Control 60226
ZWA4014

60226 In-Wall Smart Fan Control

Thank you for your purchase!

Instructionsmade easy Read instructions or watch easy-tofollow video.
Scan code or visit Scan code or visit yjasco.com/60226i.

For additional Enbrighten products, visit our website www.Jasco.com.
Register your product Receive exclusive deals and register your product.
Scan code or visit byjasco.com/deals.

| Like our product? Leave a review on your favorite retailer website or amazon.com.
---|---
| Having problems? Let us know how we can help. Call 1-800-654-8483 between 7AM-8PM, M-F, Central Time.

ADDING YOUR DEVICE TO A Z-WAVE NETWORK

  1. Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
  2.  Once the controller is ready to add your device, push the toggle up or down.

You have complete control to turn your fixture ON/OFF according to groups, scenes, schedules and interactive automations programmed by your controller.
If your Z-Wave certified controller features remote access, you can control your fixture from your mobile devices.
If prompted by the controller to enter the S2 security code, refer to the QR code/security number on the side of the box or the QR code label on the product(see Figure 1). Enter the 5-digit code.
Figure 1:



https://byjasco.com/HEP-ET/20000-99999/39339| https://byjasco.com/HEP- ET/20000-99999/39339

TO REMOVE AND RESET THE DEVICE

  1. Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
  2. Once the controller is ready to remove your device, push the toggle up or down.

TO RETURN YOUR SWITCH TO FACTORY DEFAULTS

  1. Slide the air gap switch right.
  2. While pressing the OFF (bottom) button, push the air gap left and continue pressing the OFF button. The LED flashes through the eight colors once.

NOTE: This should only be used if your network’s primary controller is missing or otherwise inoperable.
NOTE: SmartStart enabled products can be added into a Z-Wave network by scanning the QR code on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.

SPECIFICATIONS — IMPORTANT!

ZWA4014 Construction of control: Independently Mounted for Flush Mounting
Voltage: 120Vac, 60Hz Type of Action: Type 1.B Action (for air gap)
1/10hp(75W), motor Pollution Degree: 2
Signal (frequency): 908.4/916MHz Rated Impulse Voltage: 2500 V

Maximum loads: 1/10hp(75W), motor no more than two identical fans to the switch. Not to exceed 1/10hp(75W), motor resistive load.
CONTROLS FAN MOTOR ONLY. For use only with split-capacitor or shaded-pole ceiling fan motors.
Operating temperature range: 0-40° C For indoor use only Specifications subject to change without notice due to continuing product improvement

FEATURES

IMPORTANT! The fixture controlled by the Z-Wave in-wall smart fan control must not exceed ratings. The fan control is designed only for use with permanently installed fixtures.
Get to you know your Z-Wave smart fan control

  • Turn ON/OFF and adjust fan speed levels manually or remotely via the Z-Wave controller
  • Can be included in multiple groups and scenes
  • May be used in single-pole installation or with up to two Enbrighten, UltraPro orJascoPro Series add-on switches in 3-way or 4-way wiring configurations
  • Uses a standard, toggle-style wallplate for single-gang installations (wallplate  not included)
  • Blue LED indicates switch location in a dark room
  • Screw terminal installation – requires wiring connections for line (hot), load, neutral and ground. Traveler wire required for 3-way installation
  • This Z-Wave device has advanced features that allow you to customize your experience. These features can only be adjusted by a Z-Wave enabled controller that supports the Z-Wave configuration command class. For a complete list of adjustable configurations, visit www.ezzwave.com/config

NOTE: This smart device only controls the fan motor and does not control any lighting connected to the fan. If your fan has an integrated light, a second switch must be installed to control the lighting directly. No more than two identical fans should be connected to the fan control. The total load of the fan(s) should not exceed 1/10hp(75W), motor. A. Ground (Green/bare)
B. Line or load (Black)
C. Line or load (Black)
D. Traveler (Red/other)
E. Neutral (White)
F. Up — press & release to turn fan on, press & hold to increase fan speed
G. Down — press & release to turn fan off Press & hold to decrease fan speed
H. Menu button
I. Air gap switch — slide the air gap switch right to disconnect the power. Push it left for normal operation.

WARNING — SHOCK HAZARD
Turn OFF the power to the branch circuit for the device fixture at the service panel. All wiring connections must be made with the power OFF to avoid personal injury and damage to the device. This device is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada. If you are unsure or uncomfortable about performing this installation, consult a qualified electrician.

REMOVE SINGLE-POLE SWITCH

  1. Shut off power to the circuit at the circuit breaker or fuse box.
    IMPORTANT! Verify power to switch box is OFF before continuing.enbrighten 60226 In-Wall Smart Fan Control -
NEUTRAL

  2.  Remove  wallplate.

  3.  Remove the switch mounting screws.

  4. Carefully remove the switch from the switch box – DO NOT  disconnect the wires.

  5.  Identify the following wires in the switch box:
    A. Ground – Green/bare
    B. Line (hot) – Black (connected to power)
    C. Load – Black (connected to lighting)
    D. Neutral – White

  6. Disconnect the wires from the existing switch – label wires according to the previous terminal connections.

SINGLE-SWITCH WIRING

WIRING REQUIREMENTS
Attach using the enclosure’s holes, strip insulation 5/8in. (16mm).
UL specifies the tightening torque for the screws is 12lbf-in (14Kgf- cm).enbrighten 60226 In-Wall Smart Fan Control -
terminal

  1. Connect green/bare wire to the GROUND terminal.

  2. Connect the black wire from the light to either LINE/LOAD terminal.

  3. Connect the black wire from the power source (hot) to the other LINE/LOAD terminal.

  4.  Connect the white wire to the NEUTRAL terminal – use jumper if necessary.
    NOTE: The traveler terminal is only used for multi-switch wiring and is not used in a two-way system (one switch and one load).

  5.  Secure the device into the switch box with the provided mounting screws – ensure wires are not pinched or crushed.

  6.  Install the wallplate.

CYCLE LED

The LED behind the fan control acts as a guide light or status indicator.
How to cycle through options:

  1. Press menu button for five seconds

  2. Press up three times and down one time quickly – indicator flashes blue

  3. Push the toggle up:
    A. Once for LED ON when the load is OFF – illuminates orange to confirm
    B. Twice for LED ON when the load is ON – illuminates yellow to confirm
    C. Three times for always OFF – illuminates pink to confirm
    D. Four times for always ON – illuminates purple to confirm

  4. Press menu button once to save – indicato  flashes green twice

CHANGE LED INDICATOR COLOR

The LED indicator color can be changed from the device.

  1.  Press menu button for five seconds
  2.  Press toggle up once and down once once – LED illuminates in selected color
  3. Press top or bottom paddle to cycle through color options:
    • Red| • Blue (default)
    ---|---
    • Orange| • Pink
    • Yellow| • Purple
    • Green| • White
  4. Press menu button once to save – indicator flashes green twice

enbrighten 60226 In-Wall Smart Fan Control - screwsInsert wires into holes, DO NOT wrap wires around screws DO NOT remove screws

STANDARD 3-WAY SWITCH WIRING

IMPORTANT! The Z-Wave device operates with add-on switches by default. To install it with a standard 3-way switch, follow the steps under 3-way configuration. The instructions below are for wiring a standard 3-way switch. See the add-on switch manual to install add-on switches.enbrighten 60226 In-
Wall Smart Fan Control - TRAVELER 2enbrighten 60226 In-Wall Smart Fan Control -
standard

LINE SIDE (Z-WAVE DEVICE)

  1. Shut off power to the circuit at the cicuit or fuse box
  2.  Remove line side wallplate
  3. Remove switch from line side switch box – DO NOT disconnect wires
  4. Label wire from the power source LINE
  5. Label one remaining wire traveler 1 – note the color of this wire for installation of the 3-way switch
  6. Label the other remaining wire traveler 2
  7.  Disconnect all wires from the switch
  8. Connect green/bare wire to the GROUND terminal
  9. Connect the line wire to either LINE/LOAD terminal
  10.  Connect the traveler 1 wire to the other LINE/LOAD terminal
  11. Connect the traveler 2 wire to the TRAVELER terminal
  12. Connect one end of a jumper to the bundle of neutral wires using a wire nut
  13. Connect the other end of the jumper to the NEUTRAL terminal
  14. Secure the device into the switch box with the provided mounting screws – ensure wires are not pinched or crushed
  15. Install the wallplate

LOAD SIDE (3-WAY SWITCH)

  1. Remove load side wallplate
  2. Remove switch from load side switch box – DO NOT disconnect wires
  3. Label wire from the light LOAD
  4. Label traveler 1 wire – recall the wire color from the Z-Wave device installation
  5.  Label traveler 2 wire
  6.  Disconnect all wires from the switch
  7. Connect green/bare wire to the GROUND terminal
  8. Connect the load wire to the traveler 1 wire using a wire nut
  9. Connect traveler 2 to the LINE (hot) terminal
  10. Connect one end of a jumper to the bundle of neutral wires using a wire nut
  11. Connect the other end of the jumper to the COMMON terminal
  12. Secure the 3-way switch into the switch box – ensure wires are not pinched or crushed
  13.  Install the wallplate
  14. Apply power to the fuse box or circu breaker
  15. Install the wallplate
  16. Apply power to the fuse box or circuit breaker

3-WAY CONFIGURATION

The smart device is set to work with add-on switches by default. To use with a standard 3-way switch, follow the steps below.

  1. Pull out the air gap switch
  2. While pressing the top paddle, push in the air gap switch
  3. Continue pressing the top paddle until the LED flashes yellow three times to indicate standard 3-way switch configuration
  4. Repeat these steps to return to the add-on switch setting – LED flashes blue three times

ADD-ON SWITCH COMPATIBLE
Enbrighten, UltraPro and JascoPro Series add-on switches support the same features as the Z-Wave device, such as single-, double- and triple-tap functions, from all locations. It also allows operation from up to five locations and provides a uniform appearance. Visit Jasco.com to purchase add- on switches.

ADJUST FAN SPEED

The LED indicator confirms fan speed settings by flashing patterns
LOW – LED will blink every two seconds for 10 seconds
MEDIUM – LED will blink every second for 10 seconds
HIGH – LED will blink every half second for 10 seconds

  1. To decrease fan speed, press and hold lower rocker.
  2. To increase fan speed, press and hold upper rocker.

NOTE: This switch only controls the fan motor and does not control any lighting that may be part of the fan control. If your fan has an integrated light, a second light switch will need to be installed separately to control the lighting load
directly. No more than two identical fans should be controlled by one switch. The total load of the fan(s) should not exceed 1/10hp(75W), motor maximum.

Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
This device supports association command class (3 Groups)

  • Association Group 1 supports Lifeline, Binary Switch Report
  • Association Group 2 supports Basic Set and is controlled by pressing the ON or OFF button with the local load
  • Association Group 3 supports Basic Set and is controlled by double pressing the ON or OFF button
  • Each Association Group supports 5 total nodes

All brand names shown are trademarks of their respective owners
MADE IN CHINA
Distributed by Jasco Products Company LLC, 10 E. Memorial Rd., Oklahoma City, OK 73114.
This Jasco product comes with a 5-year limited warranty. Visit byjasco.com for warranty details.
Questions? Contact our U.S.-based Consumer Care at 1-800-654-8483 7AM-8PM, M-F, Central Time.
©Jasco 2022 | ZWA4014 | 60226 | 06/02/22 v1

WARRANTY

Jasco Products Company warrants this product to be free from manufacturing defects for five years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights and you may also have other rights which vary from state to state. Please contact our U.S.-based Consumer Care at 1-800-654-8483 (option 1) between 7AM–8PM, M-F, Central Time or byjasco.com if the unit should prove defective within the warranty period.

FCC/IC

IC Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
Suppliers Declaration of Conformity | Model #: 60226 | Jasco Products Co., 10 E. Memorial Rd., Oklahoma City, OK 73114, byjasco.com This device complies with Part 15 of the FCC and Industry Canada license-exempt RSS standards. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

See product label for FCC/IC certification numbers.
CAN ICES-3(B)/NMB-3(B)

https://byjasco.com/electrical-wiring-support/
Scan code for it alternate 3-way wiring process

References