SPECIFICATIONS

Technology: Proximity (13.5 MHz, ISO14443-A)
Interface: RS-485, WS4 series compatible
Supported credentials: Mifare (Classic, Desfire, Plus, Ultralight)
Read range: Up to 6 cm
Power supply: 9 – 14 VDC, 120 mA
Sound Indicator: Internal buzzer
LED Indicators: Red, Green and Orange (Red + Green)
Environmental rating: Outdoor, IP65
Operating humidity: 5% – 95% relative humidity, non-condensing
Operating temperature: -20°C to 50°C
Mounting: Surface mount
Panel connection: Cable 0.5m
Dimensions (mm): 92 x 51 x 27

MOUNTING

Ferrite Core
MOUNTING

Rubber gasket
Front

Back

Mounting base (optional)

Wrap the wires around the ferrite core (1 turn).
The ferrite core is provided with the kit and it is used to reduce the EMI.

WIRING

Connection reader to controller WS4
WIRING

  1. Reader address

Connection two readers per RS-485 line
WIRING

The readers for Doors 1.0 and 2.0 must be at address 0 and those for Doors 1.1 and 2.1 at address 1. For doors equipped with 2 readers, one must be at address 0 and the other at address 1.
Recommended cabling:
Multiconductor cable 2 twisted pair with shielding. Max length: 80 m. The cable shielding will be connected to the fixing clamp of the access unit. If more than 80 m. are needed, then termination resistors(120 ohm) may be required at both ends of the RS-485 line, while taking into consideration the lengths proposed on our web site.

VISUAL AND AUDIO SIGNALIZATION

Access denied/Break-in/Too long opened/Reader off-line/Reader tamper/Door contact tamper: Red, fast blinking
Pre-alarm: Red, fast blinking, Continuous beep
Mantrap/Forbidden period: Red ON
Emergency/Unlocked/Free period: Green, fast blinking
Access allowed/Lock ON (toggle mode): Green ON
Last person leaves the building: Multiple beeps

SOFTWARE SETTINGS

Go to Doors, select the Reader(fig.2) and then select “Mifare/Desfire” for Card. (fig.3)
While off line, red LED blinks fast and buzzer beeps continuously. Once communication is established, the red LED and the buzzer stop. Green LED starts to blink continuously. If you want to stop the green LED, go to Settings/System Options and select for the backlight ON or OFF (not default) fig.4
SOFTWARE SETTINGS
SOFTWARE SETTINGS

CONNECTION TO PC

To update the firmware, run the XPR Toolbox and select ”WS4 readers” and ”MTPX-RS-MF V2” and click on “Open” tab. Follow the instruction in the software to set up or update firmware.
CONNECTION TO PC
CONNECTION TO PC

This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.