First Alert PC1210 Smoke Alarm User Manual
- June 12, 2024
- First Alert
Table of Contents
- First Alert PC1210 Smoke Alarm User Manual
- Features
- BASIC SAFETY INFORMATION
- INSTALLATION WHERE TO INSTALL THIS ALARM
- HOW TO INSTALL THIS ALARM
- OPTIONAL LOCKING FEATURE
- IF THE CO ALARM SIGNAL SOUNDS
- USING THE SILENCE FEATURES
- AGENCY PLACEMENT RECOMMENDATIONS
- SPECIAL COMPLIANCE CONSIDERATIONS
- FCC Compliance
- GENERAL LIMITATIONS OF SMOKE/CO ALARMS
- Troubleshooting
- LIMITED WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
First Alert PC1210 Smoke Alarm User Manual
Features
Separate sensors to detect smoke and CO; the two alarm systems work independently
Sealed-In Lithium
Battery — Sealed-in lithium power supply; no battery replacement is required
over the 10-year life of the alarm.
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
This user’s manual contains important information about your Combination of
Carbon Monoxide & Smoke Alarm’s operation. If you are installing this Alarm
for use by others, you must leave this manual—or a copy of it—with the end
user All BRK® and First Alert® Smoke Alarms conform to regulatory
requirements, including UL217, and are designed to detect particles of
combustion. Smoke particles of varying numbers and sizes are produced in all
fires.
Ionization technology is generally more sensitive than photoelectric technology at detecting small particles, which tend to be produced in greater amounts by flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a wastebasket, or a grease fire in the kitchen.
Photoelectric technology is generally more sensitive than ionization technology at detecting large particles, which tend to be produced in greater amounts by smoldering fires, which may smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. For maximum protection, use both types of Smoke Alarms on each level and in every bedroom of your home.
Follow safety rules and prevent hazardous situations:
- Use smoking materials properly. Never smoke in bed.
- Keep matches or lighters away from children;
- Store flammable materials in proper containers;
- Keep electrical appliances in good condition and don’t overload electrical circuits;
- Keep stoves, barbecue grills, fireplaces, and chimneys grease- and debris-free;
- Never leave anything cooking on the stove unattended;
- Keep portable heaters and open flames, like candles, away from flammable materials;
- Don’t let rubbish accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if they are not working properly. Smoke Alarms that do not work cannot alert you to a fire. Keep at least one working fire extinguisher on every floor, and an additional one in the kitchen. Have fire escape ladders or other reliable means of escape from an upper floor in case stairs are blocked.
BASIC SAFETY INFORMATION
IMPORTANT!
- Dangers, Warnings, and Cautions alert you to important operating instructions or to potentially hazardous situations. Pay special attention to these items.
- This Smoke/CO Alarm is approved for use in single-family residences. It is NOT designed for marine or RV use.
CAUTION!
- This combination Smoke/Carbon Monoxide Alarm has two separate alarms. The CO Alarm is not designed to detect fire or any other gas. It will only indicate the presence of carbon monoxide gas at the sensor. Carbon monoxide gas may be present in other areas. The Smoke Alarm will only indicate the presence of smoke that reaches the sensor. The Smoke Alarm is not designed to sense gas, heat, or flames
WARNING!
- This unit will not operate without battery power. The Smoke/ CO Alarm cannot work until you activate the battery power pack.
- NEVER ignore any alarm. See “If Your Smoke/CO Alarm Sounds” for more information on how to respond to an alarm. Failure to respond can result in injury or death.
- The Silence Features are for your convenience only and will not correct a problem. See “Using the Silence Features” for details. Always check your home for a potential problem after any alarm. Failure to do so can result in injury or death.
- Test this Smoke/CO Alarm once a week. If the Alarm ever fails to test correctly, have it replaced immediately! If the Alarm is not working properly, it cannot alert you to a problem.
- This product is intended for use in ordinary indoor locations of family living units. It is not designed to measure CO levels in compliance with Occupational Safety and Health Administration (OSHA) commercial or industrial standards.
- Individuals with medical conditions that may make them more sensitive to carbon monoxide may consider using warning devices that provide audible and visual signals for carbon monoxide concentrations under 30 ppm. For additional information on carbon monoxide and your medical condition contact your physician.
INSTALLATION WHERE TO INSTALL THIS ALARM
Minimum coverage for Smoke Alarms, as recommended by the National Fire
Protection Association (NFPA), is one Smoke Alarm on every floor, in every
sleeping area, and in every bedroom (See “Regulatory Information For Smoke
Alarms” for details on the NFPA recommendations). For CO Alarms, the National
Fire Protection Association (NFPA) recommends that a CO Alarm should be
centrally located outside of each separate sleeping area in the immediate
vicinity of the bedrooms. For added protection, install additional CO Alarms
in each separate bedroom, and on every level of your home.
NOTE: For added protection, install an additional Smoke/CO Alarm at least
15 feet (4.6 meters) away from the furnace or fuel-burning heat source where
possible. In smaller homes or in manufactured homes where this distance cannot
be maintained, install the Alarm as far away as possible from the furnace or
other fuel-burning source. Installing the Alarm closer than 15 feet (4.6
meters) will not harm the Alarm, but may increase the frequency of unwanted
alarms.
In general, install a combination of Smoke and Carbon Monoxide Alarms:
- On every level of your home, including finished attics and basements.
- Inside every bedroom, especially if people sleep with the door partly or completely closed.
- In the hall near every sleeping area. If your home has multiple sleeping areas, install a unit in each. If a hall is more than 40 feet (12 meters) long, install a unit at each end.
- At the top of first-to-second-floor stairs.
- At the bottom of the basement stairs.
- For additional coverage, install Alarms in all rooms, halls, and storage areas, where temperatures normally remain between 40˚ F and 100˚ F (4.4˚ C and 37.8˚ C).
SUGGESTED AREAS FOR INSTALLING
SMOKE ALARMS CO ALARMS AND COMBO UNITS CO ALARMS OR A COMBINATION SMOKE/CO
ALARMS SMOKE ALARMS KEY
Suggested locations are based on NFPA recommendations (NFPA 72 for Smoke
Alarms and NFPA 720 for Carbon Monoxide Alarms). Always refer to national and
local codes before beginning any installation
- When installed on the wall, the top edge of the Smoke Alarms should be placed between 4 inches (102 mm) and 12 inches (305 mm) from the wall/ceiling line.
- When installing it on the ceiling, place the alarm as close to the center as possible.
- In either case, install at least 4 inches (102 mm) from where the wall and ceiling meet. See “Avoiding Dead Air Spaces” for more information.
- NOTE : For any location, make sure no door or other obstruction could keep carbon monoxide or smoke from reaching the Alarm.
Installing Smoke/CO Alarms in Mobile Homes
For minimum security install one Smoke/CO Alarm as close to each sleeping area
as possible. For more security, put one unit in each room. Many older mobile
homes (especially those built before 1978) have little or no insulation. If
your mobile home is not well insulated, or if you are unsure of the amount of
insulation, it is important to install units on inside walls only.
WHERE THIS ALARM SHOULD NOT BE INSTALLED
Do NOT locate this Smoke/CO Alarm:
- In garages, furnace rooms, crawl spaces, and unfinished attics.
- Avoid extremely dusty, dirty, or greasy areas.
- Where combustion particles are produced. Combustion particles form when something burns. Areas to avoid include poorly ventilated kitchens, garages, and furnace rooms.
- Keep units at least 20 feet (6 meters) from the sources of combustion particles (stove, furnace, water heater, space heater) if possible.
- In areas where a 20-foot (6 meters) distance is not possible – in modular, mobile, or smaller homes, for example – it is recommended the Smoke Alarm be placed as far from these fuel-burning sources as possible.
- The placement recommendations are intended to keep these Alarms at a reasonable distance from a fuel-burning source, and thus reduce “unwanted” alarms. Unwanted alarms can occur if a Smoke/CO
- The alarm is placed directly next to a fuel-burning source. Ventilate these areas as much as possible.
- Within 5 feet (1.5 meters) of any cooking appliance. In air streams near kitchens. Air currents can draw cooking smoke into the smoke sensor and cause unwanted alarms.
- In extremely humid areas. This Alarm should be at least 10 feet (3 meters) from a shower, sauna, humidifier, vaporizer, dishwasher, laundry room, utility room, or other source of high humidity.
- In direct sunlight.
- In turbulent air, like near ceiling fans or open windows. Blowing air ay, prevents CO or smoke from reaching the sensors.
- In areas where the temperature is colder than 40˚ F (4.4˚ C) or hotter than 100˚ F (37.8˚ C). These areas include non-airconditioned crawl spaces, unfinished attics, uninsulated or poorly insulated ceilings, porches, and garages.
- In insect-infested areas. Insects can clog the openings to the sensing chamber.
- Less than 12 inches (305 mm) away from fluorescent lights.
- Electrical “noise” can interfere with the sensor.
- In “dead air” spaces. See “Avoiding Dead Air Spaces”.
AVOIDING DEAD AIR SPACES
“Dead air” spaces may prevent smoke from reaching the Smoke/CO Alarm. To avoid
dead air spaces, follow the installation recommendations below. On ceilings,
install Smoke/CO Alarms as close to the center of the ceiling as possible. If
this is not possible, install the Smoke/CO Alarm at least 4 inches (102 mm)
from the wall or corner. For wall mounting (if allowed by building codes), the
top edge of Smoke/CO Alarms should be placed between 4 inches (102 mm) and 12
inches (305 mm) from the wall/ceiling line, below typical “dead air” spaces.
On a peaked, gabled, or cathedral ceiling, install the first Smoke/CO Alarm
within 3 feet (0.9 meters) of the peak of the ceiling, measured horizontally.
Additional Smoke/CO Alarms may be required depending on the length, angle,
etc. of the ceiling’s slope. Refer to NFPA 72 for details on requirements for
sloped or peaked ceilings.
HOW TO INSTALL THIS ALARM
PARTS OF THIS SMOKE/CO ALARM
- Test/Silence button
- Dual Power indicator light and Alarm indicator: Green LED provides a visual indication of an Alarm Memory condition; Red LED provides a visual indication of an Alarm and Hush modes
- Mounting bracket
- Mounting slots
- Turn this way to remove
- Turn this way to attach
Tools you will need: pencil, drill with 3/16” or 5mm drill bit, flathead screwdriver, hammer This unit is designed to be mounted on the ceiling, or on the wall if necessary.
FOLLOW THESE SIMPLE STEPS
Hold the mounting bracket against the ceiling (or wall) so the two clusters of
universal mounting holes are aligned approximately at 9:00 and 3:00 o’clock
positions. See image. Choose one of the three sets of holes shown, A, B, or C
(see image) and trace around one of the sets. Be sure to choose a top and
bottom slot on opposite sides so you can rotate the Universal mounting bracket
into position later. This will make it easier in the future to remove the
mounting bracket without completely removing the screws.
WARNING!
-
Do not install this Alarm over an existing electrical box. Only AC-powered units are intended for installation over electrical boxes.
-
Put the unit where it won’t get covered with dust when you drill the mounting holes.
-
Using a 3/16” (5 mm) drill bit, drill a hole through the center of the oval outlines you traced.
-
Insert the plastic screw anchors (in the plastic bag with screws) into the holes. Tap the screw anchors gently with a hammer, if necessary, until they are flush with the ceiling or wall.
-
Install the screws but do not tighten them completely. Attach the mounting bracket by aligning the screws in the open portion of the universal mounting slots and rotating the bracket into place. Tighten the screws until they are snug to secure the bracket. Do not over-tighten.
-
Activating the battery. Mount the alarm to the mounting bracket to activate. Once the unit is activated, it cannot be turned off.
NOTE: After you activate the battery, the power indicator light may flash. (If the unit alarms, the light will blink rapidly, and the horn will repeatedly sound 3 beeps, pause, 3 beeps.) Once the Smoke alarm is on the bracket, you can rotate the Alarm to adjust the alignment. -
Test the Alarm. See “Weekly Testing.”
-
After 10 years of operation or a Low Battery warning, deactivate the Alarm: Insert a tool below the edge where shown and break the tab. Then slide the activation switch to deactivate mode.
NOTE: At the end of life or low battery indication (chirp): the unit must be put into deactivation mode to deactivate the remaining stored energy in the battery. The unit will no longer function once put into this mode. The unit will resist re-mounting.
OPTIONAL LOCKING FEATURE
The optional locking feature is designed to prevent the unauthorized removal of the alarm. It is not necessary to activate the lock in single-family households where unauthorized alarm removal is not a concern. Tools you will need: Needle-nose pliers or utility knife Standard flathead screwdriver The feature uses a locking pin that is molded into the mounting bracket. Remove the locking pin by using needle-nose pliers or a utility knife. To permanently remove the locking pin, insert a flathead screwdriver between the locking pin and the lock and pry the pin out of the lock.
TO LOCK THE MOUNTING BRACKET
- Using needle-nose pliers, detach the pin from the mounting bracket.
- Insert the locking pin through the hole on the back of the smoke alarm as shown in the diagram.
- When you attach the alarm to the mounting bracket the locking pin’s head will fit into a notch on the bracket.
TO UNLOCK THE MOUNTING BRACKET
- Insert a flathead screwdriver in between the mounting bracket and the locking pin.
- Pry the alarm away from the bracket by pushing up the screwdriver and turning the alarm counterclockwise (left) at the same time.
WEEKLY TESTING
- NEVER use an open flame of any kind to test this unit. You might accidentally damage or set fire to the unit or to your home. The built-in test switch accurately tests the unit’s operation as required by Underwriters Laboratories, Inc. (UL).
- NEVER use vehicle exhaust! Exhaust may cause permanent damage and voids your warranty.
- DO NOT stand close to the alarm when the horn is sounding.
- Exposure at close range may be harmful to your hearing. When testing, step away when the horn starts sounding.
- It is important to test this unit every week to make sure it is working properly. Using the test button is the recommended way to test this Smoke/CO Alarm.
- You can test this Smoke/CO Alarm: Press and hold the Test/Silence button for 3-5 seconds until the unit starts to alarm. During testing, you will see and hear the following sequence:
- The Horn will sound 3 beeps, pause, and 3 beeps. The LED flashes Red.
- Next, the Horn will sound 4 beeps, pause, and 4 beeps. The LED flashes Red.
- If the unit does not alarm, make sure it has been activated correctly, and test again. If the unit still does not alarm, replace it immediately
REGULAR MAINTENANCE
This unit has been designed to be as maintenance-free as possible, but there
are a few simple things you must do to keep it working properly.
- Test it at least once a week.
- Clean the Smoke/CO Alarm at least once a month; gently vacuum the outside of the Smoke/CO Alarm using your household vacuum’s soft brush attachment. A can of clean compressed air (sold at computer or office supply stores) may also be used. manufacturer instructions for use. Test the Smoke/CO Alarm. Never use water, cleaners, or solvents since they may damage the unit.
- If the Smoke/CO Alarm becomes contaminated by excessive dirt, dust, and/or grime, and cannot be cleaned to avoid unwanted alarms, and replace the unit immediately.
- Relocate the unit if it sounds like frequent unwanted alarms. See
- “Where This Alarm Should Not Be Installed” for details. Actual battery service life depends on the Smoke/CO Alarm and the environment in which it is installed.
- Regardless of the manufacturer’s suggested battery life, you MUST replace the Alarm immediately once the unit starts “chirping” (the “low battery warning”).
IF YOUR SMOKE/CO ALARM SOUNDS
WHAT TO DO FIRST–IDENTIFY THE TYPE OF ALARM
- Type of Alarm
- Carbon Monoxide (CO)
- What You See and Hear
- CO LED: Flashes Red
- Horn: 4 beeps, pause, 4 beeps,
- Smoke LED: Flashes Red
- Horn: 3 beeps, pause, 3 beeps, pause
IF THE CO ALARM SOUNDS“ALARM-MOVE TO FRESH AIR”
If you hear the CO alarm horn and the CO red light is flashing, move everyone
to a source of fresh air. DO NOT deactivate the alarm Actuation of your CO
Alarm indicates the presence of carbon monoxide (CO) which can kill you. In
other words, when your CO Alarm sounds, you must not ignore it!
IF THE CO ALARM SIGNAL SOUNDS
- Press the Test/Silence button.
- Call your emergency services, fire department, or 911. Write down the number of your local emergency service here:
- Immediately move to fresh air—outdoors or by an open door or window. Do a head count to check that all persons are accounted for. Do not re-enter the premises, or move away from the open door or window until the emergency services responder has arrived, the premises have been aired out, and your CO Alarm remains in its normal condition.
- After following steps 1-3, if your CO Alarm reactivates within a 24-hour period, repeat steps 1-3 and call a qualified appliance technician to investigate for sources of CO from fuel-burning equipment and appliances, and inspect for proper operation of this equipment. If problems are identified during this inspection have the equipment serviced immediately. Note any combustion equipment not inspected by the technician, and consult the manufacturers’ instructions, or contact the manufacturers directly, for more information about CO safety and this equipment. Make sure that motor vehicles are not, and have not, been operating in an attached garage or adjacent to the residence. Write down the number of a qualified appliance technician here:
NOTE: A qualified appliance technician is defined as “a person, firm, corporation, or company that either in person or through a representative is engaged in and responsible for the installation, testing, servicing, or replacement of heating, ventilation, air conditioning (HVAC) equipment, combustion appliances and equipment, and/or gas fireplaces or other decorative combustion equipment.”
IF THE SMOKE ALARM SOUNDS RESPONDING TO AN ALARM
- If the unit alarms and you are not testing the unit, it is warning you of a potentially dangerous situation that requires your immediate attention.
- NEVER ignore any alarm. Ignoring the alarm may result in injury or death.
- Never remove the batteries from a battery-operated Smoke/CO Alarm to stop an unwanted alarm (caused by cooking smoke, etc.)
- Removing batteries disables the alarm so it cannot sense smoke, and removes your protection. Instead, open a window or fan the smoke away from the unit. The alarm will reset automatically.
- If the unit alarms get everyone out of the house immediately.
WHAT TO DO IN CASE OF FIRE
- Don’t panic; stay calm. Follow your family’s escape plan.
- Get out of the house as quickly as possible. Don’t stop to get dressed or collect anything.
- Feel doors with the back of your hand before opening them. If a door is cool, open it slowly. Don’t open a hot door. Keep doors and windows closed, unless you must escape through them.
- Cover your nose and mouth with a cloth (preferably damp).
- Take short, shallow breaths.
- Meet at your planned meeting place outside your home, and do a head count to make sure everybody got out safely.
- Call the Fire Department as soon as possible from the outside.
- Give your address, then your name.
- Never go back inside a burning building for any reason.
- Contact your Fire Department for ideas on making your home safer.
- Alarms have various limitations. See “General Limitations of Smoke/CO Alarms” for details.
USING THE SILENCE FEATURES
Never deactivate the unit to quiet an unwanted alarm. Deactivating the alarm
disables the unit and removes your protection. The Silence Feature is intended
to temporarily silence the horn while you identify and correct the problem. Do
not use the Silence Feature in emergency situations. It will not correct a CO
problem or extinguish a fire. The Silence Feature can temporarily quiet an
unwanted alarm for several minutes. Press the Test/Silence button on the alarm
cover for at least 3-5 seconds. After the Test/Silence button is released, the
Red LED blinks during the silence mode. When the Smoke Alarm is Silenced When
the CO Alarm is Silenced The Smoke Alarm will remain silent for up to 15
minutes, then return to normal operation. If the smoke has not cleared–or
continues to increase–the device will go back into alarm. The CO Alarm will
remain silent for up to 4 minutes. After 4 minutes, if CO levels remain
potentially dangerous the
horn will start sounding again.
SILENCING THE LOW BATTERY WARNING
This silence feature can temporarily quiet the low battery warning “chirp”.
Press the Test/Silence button on the alarm. Once the low battery warning
“chirp” silence feature is activated, the unit continues to flash the
Greenlight once a minute. After some time, the low battery “chirp” will
resume. Replace the Alarm as soon as possible; this unit will not operate
without battery power! To deactivate this feature: Press the Test/Silence
button again. The unit will go into Test Mode and the low battery warning will
resume (LED flashes and unit sounds “chirp” once a minute).
SILENCING THE END-OF-LIFE SIGNAL
This silence feature can temporarily quiet the End of Life warning “chirp” for
up to 2 days. You can silence the End of Life warning “chirp” by pressing the
Test/Silence button. The horn will chirp, acknowledging that the End of Life
silence feature has been activated. After approximately 2 days, the End of
Life “chirp” will resume.
WHAT YOU NEED TO KNOW ABOUT CO WHAT IS CO?
CO is an invisible, odorless, tasteless gas produced when fossil fuels do not
burn completely, or are exposed to heat (usually fire). Electrical appliances
typically do not produce CO. These fuels include Wood, coal, charcoal, oil,
natural gas, gasoline, kerosene, and propane. Common appliances are often
sources of CO. If they are not properly maintained, are improperly ventilated,
or malfunction, CO levels can rise quickly. CO is a real danger now that homes
are more energy efficient. “Air-tight” homes with added insulation, sealed
windows, and other weatherproofing can “trap” CO inside.
SYMPTOMS OF CO POISONING
These symptoms are related to CO POISONING and should be discussed with ALL
household members. Mild Exposure: Slight headache, nausea, vomiting, fatigue
(“flu-like” symptoms). Medium Exposure: Throbbing headache, drowsiness,
confusion, fast heart rate.
Extreme Exposure: Convulsions, unconsciousness, heart and lung failure. Exposure to Carbon Monoxide can cause brain damage and death. This CO Alarm measures exposure to CO over time. It alarms if CO levels are extremely high in a short period of time, or if CO levels reach a certain minimum over a long period of time. The CO Alarm generally sounds an alarm before the onset of symptoms in average, healthy adults. Why is this important? Because you need to be warned of a potential CO problem while you can still react in time. In many reported cases of CO exposure, victims may be aware that they are not feeling well, but become disoriented and can no longer react well enough to exit the building or get help. Also, young children and pets may be the first affected. The average healthy adult might not feel any symptoms when the CO Alarm sounds. However, people with cardiac or respiratory problems, infants, unborn babies, pregnant mothers, or elderly people can be more quickly and severely affected by CO. If you experience even mild symptoms of CO poisoning, consult your doctor immediately!
FINDING THE SOURCE OF CO AFTER AN ALARM
Carbon monoxide is an odorless, invisible gas, which often makes it difficult
to locate the source of CO after an alarm. These are a few of the factors that
can make it difficult to locate sources of CO:
- House well-ventilated before the investigator arrives.
- A problem caused by “back drafting.”
- Transient CO problem caused by special circumstances
- Because CO may dissipate by the time an investigator arrives, it may be difficult to locate the source of CO. BRK Brands, Inc. shall not be obligated to pay for any carbon monoxide investigation or service call.
POTENTIAL SOURCES OF CO IN THE HOME
Fuel-burning appliances like portable heater, gas or wood-burning fireplace,
gas kitchen range or cooktop, and gas clothes dryer. Damaged or insufficient
venting: corroded or disconnected water heater from the vent pipe, leaking
chimney pipe or flue, or cracked heat exchanger blocked or clogged chimney
opening. Improper use of appliance/device: operating a barbecue grill or
vehicle in an enclosed area (like a garage or screened porch). Transient CO
Problems: “Transient” or on-again-off-again CO problems can be caused by
outdoor conditions and other special circumstances.
The following conditions can result in transient CO situations:
- Excessive spillage or reverse venting of fuel appliances caused by outdoor conditions such as:
- Wind direction and/or velocity, including high, gusty winds. Heavy air in the vent pipes (cold/humid air with extended periods between cycles).
- Negative pressure differential resulting from the use of exhaust fans.
- Several appliances running at the same time compete for limited fresh air.
- Vent pipe connections vibrate loose from clothes dryers, furnaces, or water heaters.
- Obstructions in or unconventional vent pipe designs can amplify the above situations.
- Extended operation of unvented fuel-burning devices (range, oven, fireplace).
- Temperature inversions, which can trap exhaust close to the ground.
- Car idling in an open or closed attached garage or near a home. These conditions are dangerous because they can trap exhaust in your home. Since these conditions can come and go, they are also hard to recreate during a CO investigation.
HOW CAN I PROTECT MY FAMILY FROM CO-POISONING?
A CO Alarm is an excellent means of protection. It monitors the air and sounds
a loud alarm before Carbon Monoxide levels become threatening for average,
healthy adults. A CO Alarm is not a substitute for proper maintenance of home
appliances. To help prevent CO problems and reduce the risk of CO poisoning:
-
Clean chimneys and flues yearly. Keep them free of debris, leaves, and nests for proper airflow. Also, have a professional check for rust and corrosion, cracks, or separations. These conditions can prevent proper air movement and cause
back drafting. Never “cap” or cover a chimney in any way that would block airflow. -
Test and maintain all fuel-burning equipment annually. Many local gas or oil companies and HVAC companies offer appliance inspections for a nominal fee.
-
Make regular visual inspections of all fuel-burning appliances. Check appliances for excessive rust and scaling. Also, check the flame on the burner and pilot lights. The flame should be blue. A yellow flame means fuel is not being burned completely and CO may be present. Keep the blower door on the furnace closed. Use vents or fans when they are available on all fuel-burning appliances. Make sure appliances are vented to the outside. Do not grill or barbecue indoors, in garages, or on screen porches.
-
Check for exhaust backflow from CO sources. Check the draft on an operating furnace for a backdraft. Look for cracks on furnace heat exchangers.
-
Check the house or garage on the other side of the shared wall.
-
Keep windows and doors open slightly. If you suspect that CO is escaping into your home, open a window or a door.
-
Opening windows and doors can significantly decrease CO levels. In addition, familiarize yourself with all the enclosed materials.
-
Read this manual in its entirety, and make sure you understand what to do if your CO Alarm sounds.
REGULATORY INFORMATION FOR SMOKE/CO ALARMS REGULATORY INFORMATION FOR CO
ALARMS WHAT LEVELS OF CO CAUSE AN ALARM?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO Alarms
to sound when exposed to levels of CO and exposure times as described below.
They are measured in parts per million (ppm) of CO over time (in minutes).
UL2034 Required Alarm Points
- If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN 4 and 15 MINUTES.
- If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN 10 and 50 MINUTES.
- If the alarm is exposed to 70 ppm if CO, IT MUST ALARM BETWEEN 60 and 240 MINUTES.
- Approximately 10% COHb exposure at levels of 10% to 95% Relative Humidity (RH).
- The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days. CO Alarms are designed to alarm before there is an immediate life threat. Since you cannot see or smell CO, never assume it’s not present.
- exposure to 100 ppm of CO for 20 minutes may not affect average, healthy adults, but after 4 hours the same level may cause headaches.
- Exposure to 400 ppm of CO may cause headaches in average, healthy adults after 35 minutes, but can cause death after 2 hours. Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon monoxide alarm UL2034.
- According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon monoxide alarms covered by these requirements are intended to respond to the presence of carbon monoxide from sources such as, but not limited to, exhaust from internal-combustion engines, abnormal operation of fuel-fired appliances, and fireplaces. CO Alarms are intended to alarm at carbon monoxide levels below those that could cause a loss of ability to react to the dangers of Carbon Monoxide exposure.”
- This CO Alarm monitors the air at the Alarm and is designed to alarm before CO levels become life-threatening. This allows you precious time to leave the house and correct the problem. This is only possible if Alarms are located, installed, and maintained as described in this manual. Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically.
- UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm), and Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million. Audible Alarm: 85 dB minimum at 10 feet (3 meters).
REGULATORY INFORMATION FOR SMOKE ALARMS
RECOMMENDED LOCATIONS FOR SMOKE ALARMS
Installing Smoke Alarms in Single-Family Residences The National Fire
Protection Association (NFPA), recommends one Smoke Alarm on every floor, in
every sleeping area, and in every bedroom. In new construction, the Smoke
Alarms must be AC-powered and interconnected. See “Agency Placement
Recommendations” for details. For additional coverage, it is recommended that
you install a Smoke Alarm in all rooms, halls, storage areas, finished attics,
and basements, where temperatures normally remain between 40˚ F (4.4˚ C) and
100˚ F (37.8˚ C). Make sure no door or other obstruction could keep smoke from
reaching the Smoke Alarms. More specifically, install Smoke Alarms:
- On every level of your home, including finished attics and basements.
- Inside every bedroom, especially if people sleep with the door partly or completely closed.
- In the hall near every sleeping area. If your home has multiple sleeping areas, install a unit in each. If a hall is more than 40 feet long (12 meters), install a unit at each end.
- At the top of the first-to-second-floor stairway, and at the bottom of the basement stairway.
IMPORTANT
Specific requirements for Smoke Alarm installation vary from state to state
and from region to region. Check with your local Fire Department for current
requirements in your area. It is recommended AC or AC/DC units be
interconnected for added protection.
AGENCY PLACEMENT RECOMMENDATIONS
Standards: Underwriters Laboratories Inc. Single and Multiple Station Smoke Alarms 217.
NFPA 72 Chapter 29
“For your information, the National Fire Alarm and Signaling Code,
NFPA 72, reads as follows:”
Required Detection.
Where required by other governing laws, codes, or standards for a specific type of occupancy, approved single and multiple-station smoke alarms shall be installed as follows:
- In all sleeping rooms and guest rooms
- Outside of each separate dwelling unit sleeping area, within 21 ft 6.4 m) of any door to a sleeping room, with the distance measured along a path of travel
- On every level of a dwelling unit, including basements
- On every level of a residential board and care occupancy (small facility), including basements and excluding crawl spaces and unfinished attics
- In the living area(s) of a guest suite
- In the living area(s) of a residential board and care occupancy (small facility)
(Reprinted with permission from NFPA 72®, National Fire Alarm and Signaling Code Copyright © 2010 National Fire Protection Association, Quincy, MA 02269. This reprinted material is not the complete and official position of the National Fire Protection Association, on the referenced subject which is represented only by the standard in its entirety), (National Fire Alarm and Signaling Code® and NFPA 72® are registered trademarks of the National Fire Protection Association, Inc., Quincy, MA 02269).
California State Fire Marshal (CSFM)
Early warning detection is best achieved by the installation of fire detection
equipment in all rooms and areas of the household as follows: A Smoke Alarm
was installed in each separate sleeping area (in the vicinity, but outside
bedrooms), and Heat or Smoke Alarms in the living rooms, dining rooms,
bedrooms, kitchens, hallways, finished attics, furnace rooms, closets, utility
and storage rooms, basements, and attached garages.
ABOUT SMOKE ALARMS
Battery (DC) operated Smoke Alarms: Provide protection even when electricity
fails, provided the batteries are fresh and correctly installed. Units are
easy to install and do not require professional installation. AC-powered Smoke
Alarms: Can be interconnected so if one unit senses smoke, all units alarm.
They do not operate if electricity fails. AC with battery (DC) back-up: will
operate if electricity fails, provided the batteries are fresh and correctly
installed. AC and AC/DC units must be installed by a qualified electrician.
Smoke/CO Alarms for Solar or Wind Energy users and battery backup power systems: AC powered Smoke/CO Alarms should only be operated with true or pure sine wave inverters. Operating this Alarm with most battery-powered UPS (uninterruptible power supply) products or square wave or “quasi sine wave” inverters will damage the Alarm. If you are not sure about your inverter or UPS type, please consult with the manufacturer to verify. Smoke Alarms for the hearing impaired: Special-purpose Smoke Alarms should be installed for the hearing impaired. They include a visual alarm and an audible alarm horn and meet the requirements of the Americans With Disabilities Act. Can be interconnected so if one unit senses smoke, all units alarm. Smoke alarms are not to be used with detector guards unless the combination has been evaluated and found suitable for that purpose. All these Smoke Alarms are designed to provide early warning of fires if located, installed, and cared for as described in the user’s manual and if smoke reaches the Alarm. If you are unsure which type of Smoke Alarm to install, refer to the National Fire Protection Association (NFPA) Standard 72 (National Fire Alarm and Signaling Code) and NFPA 101 (Life Safety Code). National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269-9101. Local building codes may also require specific units in new construction or in different areas of the home.
SPECIAL COMPLIANCE CONSIDERATIONS
This Smoke Alarm is suitable for use in apartments, condominiums, townhouses,
hospitals, daycare facilities, health care facilities, boarding houses, group
homes, and dormitories provided a primary fire detection system already exists
to meet fire detection requirements in common areas like lobbies, hallways, or
porches. Using this Smoke Alarm in common areas may not provide sufficient
warning to all residents or meet local fire protection ordinances/regulations.
This Smoke Alarm alone is not a suitable substitute for a complete fire
detection system in places housing many people—like apartment buildings,
condominiums, hotels, motels, dormitories, hospitals, health care facilities,
nursing homes, daycare facilities, or group homes of any kind. It is not a
suitable substitute for complete fire detection systems in warehouses,
industrial facilities, commercial buildings, and special-purpose non-
residential buildings which require special fire detection and alarm systems.
Depending on the building codes in your area, this Smoke Alarm may be used to
provide additional protection in these facilities. In new construction, most
building codes require the use of AC or AC/ DC-powered Smoke Alarms only. In
existing construction, AC, AC/DC, or DC-powered Smoke Alarms can be used as
specified by local building codes. Refer to NFPA 72 (National Fire Alarm and
Signaling Code) and NFPA 101 (Life Safety Code), local building codes, or
consult your Fire Department for detailed fire protection requirements in
buildings not defined as “households”.
HUD MAP Program
Certain HUD battery-powered Smoke Alarm applications, especially those that
fall under HUD 223(f) MAP (Multi-family Accelerated Processing), may require a
10 Year sealed tamper-resistant battery. This alarm does not meet that
requirement. Substitute First Alert SA340B.
FCC Compliance
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that of the receiver.
- Consult the dealer or an experienced radio or TV technician for help.
Warning: Changes or modifications to the product, not expressly approved by First Alert / BRK Brands, Inc., could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received. including interference that may cause undesired operation.
GENERAL LIMITATIONS OF SMOKE/CO ALARMS
This Smoke/CO Alarm is intended for residential use. It is not intended for
use in industrial applications where Occupational Safety and Health
Administration (OSHA) requirements for Carbon Monoxide Alarms must be met. The
Smoke Alarm portion of this device is not intended to alert hearing-impaired
residents. Special-purpose Smoke Alarms should be installed for hearing-
impaired residents (CO Alarms are not yet available for the hearing-impaired).
Smoke/CO Alarms may not wake all individuals. Practice the escape plan at
least twice a year, making sure that everyone is involved – from kids to
grandparents. Allow children to master fire escape planning and practice
before holding a fire drill at night when they are sleeping. If children or
others do not readily wake to the sound of the Smoke/CO Alarm, or if there are
infants or family members with mobility limitations, make sure that someone is
assigned to assist them in the fire drill and in the event of an emergency. It
is recommended that you hold a fire drill while family members are sleeping in
order to determine their response to the sound of the Smoke/CO Alarm while
sleeping and to determine whether they may need assistance in the event of an
emergency.
Smoke/CO Alarms cannot work without power. Battery-operated units cannot work if the batteries are missing, disconnected or dead, if the wrong type of batteries are used, or if the batteries are not installed correctly. AC units cannot work if the AC power is cut off for any reason (open fuse or circuit breaker, failure along a power line or at a power station, electrical fire that burns the electrical wires, etc.). If you are concerned about the limitations of battery or AC power, install both types of units. This Smoke/CO Alarm will not sense smoke or CO that does not reach the sensors. It will only sense smoke or CO at the sensor. Smoke or CO may be present in other areas. Doors or other obstructions may affect the rate at which CO or smoke reaches the sensors. If bedroom doors are usually closed at night, we recommend you install an alarm device (Combination CO and Smoke Alarm, or separate CO Alarms and Smoke Alarms) in each bedroom and in the hallway between them.
This Smoke/CO Alarm may not sense smoke or CO on another level of the home. Example: This alarm device, installed on the second floor, may not sense smoke or CO in the basement. For this reason, one alarm device may not give adequate early warning. Recommended minimum protection is one alarm device in every sleeping area, every bedroom, and every level of your home. Some experts recommend battery-powered Smoke and CO Alarms be used in conjunction with interconnected AC-powered Smoke Alarms. For details, see “About Smoke Alarms” for details. Smoke/CO Alarms may not be heard. The alarm horn loudness meets or exceeds current UL standards of 85 dB at 10 feet (3 meters). However, if the Smoke/CO Alarm is installed outside the bedroom, it may not wake up a sound sleeper or one who has recently used drugs or has been drinking alcoholic beverages. This is especially true if the door is closed or only partly open. Even persons who are awake may not hear the alarm horn if the sound is blocked by distance or closed doors. Noise from traffic, stereo, radio, television, air conditioner, or other appliances may also prevent alert persons from hearing the alarm horn. This Smoke/CO Alarm is not intended for people who are hearing impaired.
The Alarm may not have time to alarm before the fire itself causes damage, injury, or death, since smoke from some fires may not reach the unit immediately. Examples of this include persons smoking in bed, children playing with matches, or fires caused by violent explosions resulting from escaping gas. This Smoke/CO Alarm is not a substitute for life insurance. Though this Smoke/CO Alarm warns against increasing CO levels or the presence of smoke, BRK Brands, Inc. does not warrant or imply in any way that they will protect lives. Homeowners and renters must still insure their lives.
This Smoke/CO Alarm has a limited life. Although this Smoke/CO alarm and all of its parts have passed many stringent tests and are designed to be as reliable as possible, any of these parts could fail at any time. Therefore, you must test this device weekly. The unit should be replaced immediately if it is not operating properly. This Smoke/CO Alarm is not foolproof. Like all other electronic devices, this Smoke/CO Alarm has limitations. It can only detect smoke or CO that reaches the sensors. It may not give early warning of the source of smoke or CO in a remote part of the home, away from the alarm device.
Troubleshooting
If the Alarm… | Problem… | You should… |
---|---|---|
Horn “chirps” about once per minute. | Low battery warning. | Immediately |
replace the Alarm.
Horn does three “chirps” every minute;
LED has 3 rapid Green flashes with “chirps”.
| MALFUNCTION SIGNAL. Device is not working properly, and needs to be
replaced.| Units under warranty should be returned to manufacturer for
replacement. See “Limited Warranty” for details.
The light flashes GREEN and the horn sounds 5 “chirps” every minute.| END
OF LIFE SIGNAL.
Alarm needs to be replaced.
| Immediately replace the Alarm.
Carbon Monoxide Alarm ONLY:| |
CO Alarm goes back into alarm 4 minutes after you Silence it.| CO levels
indicate a potentially dangerous situation.| IF YOU ARE FEELING SYMPTOMS OF CO
POISONING, EVACUATE your home and call 911 or the Fire Department. Refer to “If The CO Alarm Sounds” for details.
CO Alarm sounds frequently even though no high levels of CO are revealed in an
investigation.| The CO Alarm may be improperly located. Refer to “Where to
Install This Alarm” for details.| Relocate your Alarm. If frequent alarms
continue, have home rechecked for potential CO problems. You may be
experiencing an intermittent CO problem.
Smoke Alarm ONLY:| |
Smoke Alarm sounds when no smoke is visible.| Unwanted alarm may be caused by
non-emergency source like cooking smoke.
| Silence Alarm using Test/Silence button; clean the Alarm’s cover with a soft, clean cloth.
If frequent unwanted alarms continue, relocate your Alarm. Alarm may be too close to a kitchen, cooking appliance, or steamy bathroom.
LIMITED WARRANTY
3RK Brands, Inc., (“BRK”) the maker of First Alert brand products warrants that for a period of ten years from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, placement may be made with a similar product of equal or greater value. This is your exclusive warranty. This warranty is valid for the original retail purchaser from the date of the initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to alter, modify or in any way change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center. -further, the warranty does not cover Acts of God, such as fire, flood, hurricanes, and tornadoes, or any batteries that are included with this unit. 3RK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states, provinces, or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or province to province.
How to Obtain Warranty Service
Service: If service is required, do not return the product to your
retailer. In order to obtain warranty service, contact the Consumer Affairs
Division at 1-800-323-9005, 7:30 AM –
5:00 PM Central Standard Time, Monday through Friday. To assist us in serving
you, please have the model number and Jate of purchase available when calling.
For Warranty Service return to: BRK Brands, Inc., 25 Spur Drive, El Paso, TX
79906
Disposal: Waste electrical products should not be disposed of with regular household waste. Please recycle where facilities exist. Check local requirements for the disposal of Li-on electronic devices. The Alarm should be deactivated before disposal. See page 3, step 10. You can also return your Alarm to us for disposal. For the return address see above. please include a note confirming the product is been returned for disposal.
Download PDF:First Alert PC1210 Smoke Alarm User Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>