NATIONAL INSTRUMENTS PXIe-6544 Digital Waveform Instrument User Guide

June 12, 2024
NATIONAL INSTRUMENTS

NATIONAL INSTRUMENTS PXIe-6544 Digital Waveform Instrument

NATIONAL INSTRUMENTS PXIe-6544 Digital Waveform
Instrument

COMPREHENSIVE SERVICE

We offer competitive repair and calibration service, as well as easily accessible documentation and free downloadable resources.

SELL YOUR SURPLUS

We buy new, decommissioned, and surplus parts from every NI series. We work out the best solution to suit your individual needs.

Sell For Cash Get Credit  Receive a Trade-In Deal

OBSOLETE NI HARDWARE IN STOCK & READY TO SHIP

We stock New, New Surplus, Refurbished, and Reconditioned NI Hardware.

Bridging the gap between the manufacturer and your legacy test system.

Request a Quote CLICK HERE PXIe-6548

Manufacturer

National Instruments

Board Assembly Part Numbers

(Refer to Procedure 1 for identification procedure):

Part Number and Revision Description
196524A-0xL or later PXIe-6544
196525A-0xL or later PXIe-6545
199952A-0xL or later PXIe-6547
199953A-0xL or later PXIe-6548

Volatile Memory

Target Data

| Type| Size| Battery Backup| User Accessible| System Accessible|

Sanitization Procedure

---|---|---|---|---|---|---

Waveform data

| Synchronous DRAM| 512 MB| No| Yes| Yes|

Cycle Power

PCI communication

| MITE FIFO Register| 208 bytes| No| Yes| Yes|

Cycle Power

Buffering data

| FPGA Block RAM| 720 KB| No| Yes| Yes|

Cycle Power

Memory control

| FPGA Block RAM (x2)| 112 KB| No| Yes| Yes| Cycle Power
Transfer data to/from daughter card| FPGA Block RAM| 864 KB| No| Yes| Yes|

Cycle Power

Non-Volatile Memory (incl. Media Storage)

Target Data

| Type| Size| Battery Backup| User Accessible| System Accessible| Sanitization Procedure
---|---|---|---|---|---|---
Board configuration| EEPROM| 16 KB| No| No| Yes|

None

Device configuration

  • Device information
  • FPGA bitstream
  • Calibration metadata Calibration data

|

Flash

| 256 MB| No| No No Yes No| Yes Yes Yes Yes|

None None Procedure 2 None

FPGA Configuration

|

CPLD

| 64 Macro Cells| No| No| No|

None

  1. Refer to Terms and Definitions section for clarification of User and System Accessible
  2. Calibration constants that are stored on the device include information for the device’s full operating range. Any implications resulting from partial self-calibration can be eliminated by running the full self-calibration procedure.

Procedures

Procedure 1 –Board Assembly Part Number Identification:

To determine the Board Assembly Part Number and Revision, refer to the label applied to the surface of your product. The Assembly Part Number should be formatted as “P/N: 19####A-0#L”

Procedure 2 – Device Information Flash (Calibration Metadata):

The user-accessible areas of the Device Configuration Flash are exposed through a calibration Applications Programming Interface (API) in LabVIEW. To clear the calibration meta-data area, complete the following steps:

  1. Use function niHSDIO_ Init Ext Cal to create and initialize a special NI-HSDIO external calibration session. The Vi Session returned is an NI-HSDIO session that can be used during the calibration session.
  2. Call function niHSDIO_ Change Ext Cal Password to clear the calibration password that is required to initialize an external calibration session.
  3. Call function niHSDIO_ Cal Adjust Channel Voltage to clear the user-defined information of the selected channel(s).
  4. Finally, call the function niHSDIO_ Close Ext Cal with the calibration action set to ‘Commit’, in order to store the new calibration constants and data in the onboard Flash and to close the calibration session.

Terms and Definitions

Cycle Power:
The process of completely removing power from the device and its components and allowing for adequate discharge. This process includes a complete shutdown of the PC and/or chassis containing the device; a reboot is not sufficient for the completion of this process.

Volatile Memory:
Requires power to maintain the stored information. When power is removed from this memory, its contents are lost.
This type of memory typically contains application specific data such as capture waveforms.

Non-Volatile Memory:
Power is not required to maintain the stored information. Device retains its contents when power is removed.
This type of memory typically contains information necessary to boot, configure, or calibrate the product or may include device power up states.

User Accessible:
The component is read and/or write addressable such that a user can store arbitrary information to the component from the host using a publicly distributed NI tool, such as a Driver API, the System Configuration API, or MAX.

System Accessible:
The component is read and/or write addressable from the host without the need to physically alter the product.

Clearing:
Per NIST Special Publication 800-88 Revision 1, “clearing” is a logical technique to sanitize data in all User Accessible storage locations for protection against simple non-invasive data recovery techniques using the same interface available to the user; typically applied through the standard read and write commands to the storage device.

Sanitization:
Per NIST Special Publication 800-88 Revision 1, “sanitization” is a process to render access to “Target Data” on the media infeasible for a given level of effort. In this document, clearing is the degree of sanitization described.

This document is subject to change without notice For the most recent version, visit ni.com/manuals.

Customers Support

Contact: 866-275-6964
support@ni.com

Contact: 866-275-6964
support@ni.com

 1-800-915-6216

www.apexwaves.com

sales@apexwaves.com

All trademarks, brands, and names are the property of their respective owners.

LogoNATIONAL INSTRUMENTS
Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

NATIONAL INSTRUMENTS User Manuals

Related Manuals