CHAMPION POWER EQUIPMENT 93001i-EU-qs Atom Fusion Champion 3000W Inverter Generator User Manual

June 12, 2024
CHAMPION POWER EQUIPMENT

CHAMPION POWER EQUIPMENT 93001i-EU-qs Atom Fusion Champion 3000W Inverter

Generator

Product Information

  • Product Name: 3000W Portable Inverter
  • Model Number: 93001i-EU
  • Warranty: 1000 Hour Warranty or 3 Years
  • Manufacturer: Champion Power Equipment
  • Website: https://www.championpowerequipment.eu

Product Usage Instructions

  1. Move the generator to an open, outdoor area, ensuring that the exhaust is pointed away from any buildings, garages, sheds, compartments, or vehicles. Keep all objects at least 5 feet (1.5 m) away from the generator to prevent ignition of combustible materials.
  2. Add engine oil. Use 10W-30 oil and add up to 0.5L. Do not overfill and always add oil on a flat surface. Note that the oil must be changed after the first 5 hours of use.
  3. Add fuel. Use E5 or E10 fuel and do not use E15 or E85. Follow the instructions provided for adding fuel.
  4. Turn the fuel cap vent lever to the ON (|) position.
  5. Turn the EZ Start dial to the CHOKE position.
  6. Pull the recoil gently 3 times to prime, then release the cord. Use one strong rapid pull to start the generator. Repeat this step if it does not start on the first attempt. Always release the recoil back before attempting again to avoid damaging the recoil mechanism.
  7. Allow the engine to warm up and stabilize for 5-10 minutes before plugging in any electrical equipment.
  8. Never start or stop the generator with electrical devices connected or turned on.
    Note: It is important to read the entire operator’s manual to familiarize yourself with the features of the product before operating it. Failure to operate the product correctly can result in damage, personal property loss, serious injury, or even death.

Set Up

  1. Open shipping carton.  Assembly > Unboxing
  2. Move the generator outdoors
    • Move generator to an open, outdoor area. Point exhaust away. NEVER run generator close or inside any building, garages, sheds, compartments or vehicles.

-POWER-EQUIPMENT-93001i-EU-qs-Atom-Fusion-Champion-3000W-Inverter-Generator-
fig-2

  * Move generator to an open, outdoor area. Point exhaust away. NEVER run generator close or inside any building, garages, sheds, compartments or vehicles.

-POWER-EQUIPMENT-93001i-EU-qs-Atom-Fusion-Champion-3000W-Inverter-Generator-
fig-3

  1. Add oil. Assembly > Add Engine Oil

    • Recommended: 10W-30, up to 0.5L DO NOT overfill.
    • DO NOT add oil with generator tipped or at a angle always add on a flat surface
      Note:Oil MUST be changed after the first 5 hours run in.
  2. Add fuel. Assembly > Add E5 or E10 Fuel
    DO NOT use E15 or E85.

-POWER-EQUIPMENT-93001i-EU-qs-Atom-Fusion-Champion-3000W-Inverter-Generator-
fig-5

Start Up

  1. DO NOT plug in any electrical devices.
    NEVER START OR STOP THE GENERATOR WITH ELECTRICAL DEVICES CONNECTED OR TURNED ON!

  2. Turn the fuel cap vent lever to the “ON” (|) position.

  3. Turn the EZ Start dial to the “CHOKE” position.

-POWER-EQUIPMENT-93001i-EU-qs-Atom-Fusion-Champion-3000W-Inverter-Generator-
fig-8

  1. Pull the recoil gently 3 times to prime. Release back cord. Use one strong rapid pull start Repeat step 3 if it does not start first attempt. 10W-30
    Note: Always release recoil back before attempting again, rigorous pulling will damage recoil mechanism.

  2. Turn the EZ Start dial to the “RUN” position

  3. Allow engine to warm up and stabilize 5-10mins before plugging in any electrical equipment.
    Operation > Connecting Electrical Loads.