LiftMaster 98022 Wall Mount WiFi Garage Door Opener Instruction Manual
- June 12, 2024
- LiftMaster
Table of Contents
LiftMaster 98022 Wall Mount WiFi Garage Door Opener
This Quick Start Guide is intended to highlight a typical installation; these instructions are not intended to be comprehensive. Because each application is unique, it is the responsibility of the purchaser, designer, installer and end user to ensure that the total door system is safe for intended use. Please consult the manual for further information at: www.liftmaster.com/catalogresourcesv3/en- us/shared/files/tucmanuals/114a4961.pdf. To watch a video, go to https://www.youtube.com/watch?v=MnUVdP4b9uE
This garage door opener is compatible with:
- Doors that use a torsion bar and springs. The torsion bar must be 1″ (2.5 cm) diameter. NOT compatible with reverse wound drums.
- 4-6″ (10-15 cm) drums. NOT compatible with tapered drums over 6″ (15 cm).
- High lift doors up to 54″ (137.2 cm) high and standard lift sectional doors up to 14 ft. (4.3 m) high.
- Doors up to 18 ft. (5.5 m) wide.
- Doors up to 180 sq. ft. (16.7 sq. m).
Carton Inventory
Garage Door Opener, Smart Control Panel®, 3-Button Remote Control, Battery,
Collar, Mounting Bracket, Automatic Garage Door Lock, Cable Tension Monitor,
MyQ® LED Remote Light, The Protector System® (1 Sending Sensor and 1 Receiving
Sensor), Safety Reversing Sensor Bracket (2), 2 Conductor Bell Wire, Safety
Labels and Literature
Hardware
Screw #10-32 (2), Screw 14-10×2″ (4), Handle, Rope, Screw 1/4″-20×1/2″ (2),
Drywall, Anchor (Screw-In) (2), Screw 8-32×1″ (2), Screw 6ABx1-1/4″ (2),
Drywall Anchor (2), Screw 6-32×1″ (2), Carriage Bolt 1/4″-20×1/2″ (2), Wing
Nut 1/4″-20 (2)
Hardware for MyQ LED Remote Light
Drywall Anchor (Screw-In) (2), Screw #6×1″ (2)
IMPORTANT INSTALLATION INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
- THIS QUICK START IS NOT INTENDED TO REPLACE THE MANUAL, BUT SERVES AS A REMINDER FOR THOSE FAMILIAR WITH THE MANUAL AND THE INSTALLATION OF THIS PRODUCT.
- READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS IN THE INSTALLATION MANUAL.
- Install garage door opener ONLY on properly balanced and lubricated garage door. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.
- ALL repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing opener.
- Disable ALL locks and remove ALL ropes connected to garage door BEFORE installing opener to avoid entanglement.
- Where possible, install the door opener 7 feet (2.13 m) or more above the floor.
- Mount the emergency release within reach, but at least 6 feet (1.83 m) above the floor and avoiding contact with vehicles to avoid accidental release.
- NEVER connect garage door opener to power source until instructed to do so.
- NEVER wear watches, rings or loose clothing while installing or servicing opener. They could be caught in garage door or opener mechanisms.
- Install wall-mounted garage door control:
- within sight of the garage door.
- out of reach of small children at a minimum height of 5 feet (1.53 m) above floors, landings, steps or any other adjacent walking surface.
- away from ALL moving parts of the door.
- Install the emergency release marking. Attach the marking on or next to the emergency release. Install the entrapment warning placard next to the door control in a prominent location.
- Place emergency release/safety reverse test label in plain view on inside of garage door.
- Upon completion of installation, test safety reversal system. Door MUST reverse on contact with a 1-1/2″ (3.8 cm) high object (or a 2×4 laid flat) on the floor.
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
PLANNING
Inspect the proposed installation area to make sure it meets the requirements below. The garage door opener can be installed on either side of the door. The illustrations shown are for installation on the left side.
- Inspect the torsion bar while raising and lowering the door; there should be no noticeable shifting or vibrating of the door. If the movement is not corrected, the life of the garage door opener will be greatly reduced.
- Check the seal on the bottom of the door. Any gap between the floor and the bottom of the door must not exceed 1/4″ (6 mm).
- Lift the door halfway up. Release the door. If balanced, it should stay in place, supported entirely by its springs. Doors heavier than 650 lbs. should NOT open or fall rapidly.
Tools Needed
Additional Items You May Need
Extension brackets (Model 041A5281-1) or wood blocks: Extension brackets or
wood blocks may be needed to install the safety reversing sensors.
- Fastening hardware: Floor mounting of the safety reversing sensors requires hardware not provided.
- 90° connector for cable conduit or flex cable adapter: Required for permanent wiring.
INSTALLATION
Assemble the Garage Door Opener
- Attach the collar to the motor shaft with the set screws facing out. Tighten the set screws to the motor shaft. Tighten 1/4 – 1/2 turn after making contact with the motor shaft.
- Loosely attach the mounting bracket to the garage door opener on the same side as the collar.
Mount the Garage Door Opener
- Close the garage door completely. Slide the garage door opener onto the torsion bar. Ensure the collar does NOT touch the bearing. Use a level to align the garage door opener.
- Make sure the mounting bracket is located on a solid surface. If installing on drywall, the mounting bracket MUST be attached to a stud. Mark and drill 3/16″ pilot holes.
- Secure the mounting bracket to the wall. Tighten the mounting bracket to the garage door opener.
Attach the Emergency Release Rope and Handle
- Thread one end of the rope through the hole in the top of the red handle so “NOTICE” reads right side up. Secure with an overhand knot at least 1″ (2.5 cm) from the end of the rope to prevent slipping.
- Insert the other end of the rope through the loop in the emergency release cable and secure with an overhand knot.
- Install the Emergency Release Marking. Attach the marking on or next to the Emergency release.
Install the Automatic Garage Door Lock
Mount the lock above one of the door rollers. The third roller from the bottom
of the door is ideal for most installations. Drill holes in the track
according to the template provided. Wire to the garage door opener, see WIRING
AND POWER (A).
Install the MyQ® LED Remote Light
MyQ Remote LED Light must be installed to enable use of Timer-to- Close or MyQ
Smartphone Control of the door. The light MUST be visible if you’re standing
in the doorway of the garage. Install the light within 6 ft. (1.83 m) of an
electrical outlet so that the cord and light are away from moving parts. The
light has been factory programmed to operate with your opener.
Install the Door Control
- Install door control within sight of garage door, out of reach of small children at a minimum height of 5 ft. (1.5 m) above floors, landings, steps or any other adjacent walking surface, and away from ALL moving parts of door.
- Wire to the garage door opener, see WIRING AND POWER (C).
- Fasten the warning placard next to the door control.
Install the Protector System®
The safety reversing sensors must be connected and aligned correctly before
the garage door will move in the down direction. This is a required safety
device and cannot be disabled.
- Install and align the brackets so the safety reversing sensors will face each other across the garage door, with the beam no higher than 6″ (15 cm) above the floor.
- Wire to the garage door opener, see WIRING AND POWER (D).
- Strip 7/16″ (11 mm) of insulation from each set of wires. Separate the wires. Twist the white wires together. Twist the white/black wires together.
WIRING AND POWER
Wire the Accessories to the Garage Door Opener
- A- Automatic Garage Door Lock: Connect to either plugin.
- B- Smart Control Panel: Connect to red and white terminals.
- C- Safety Reversing Sensors: Connect white/black wires to gray terminal and white wires to white terminal.
Connect Power
To reduce the risk of electric shock, your garage door opener has a grounding
type plug with a third grounding pin. This plug will only fit into a grounding
type outlet. If the plug doesn’t fit into your outlet, contact a qualified
electrician to install the proper outlet.
- Plug in the garage door opener into a grounded outlet.
- Check to make sure the LEDs in both sensors are glowing steadily. The LEDs in both sensors will glow steadily if they are aligned and wired correctly. If permanent wiring is required by your local code, refer to the manual.
Install the Battery Backup
- Unplug the garage door opener.
- Connect red (+) and black (-) wires from the garage door opener to the corresponding battery terminals.
NOTE: Be sure the short antenna is not pinched by the battery door and held in place as shown. Do not run the garage door opener at this time.
ADJUSTMENTS
Identify Door Profile
To identify the door profile number, measure the full drum diameter based on
the images below.
NOTE: This step is important to ensure the proper operation of the unit.
Warning: To prevent possible SERIOUS INJURY or DEATH, follow instructions to select and set door profile for safe and proper operation.
Scan the QR code for a video demonstration.
Standard Lift Sectional Door
- Door Profile 1 = Standard to Heavy Weight Door* with a 4″ drum (Recommended).
- Door Profile 2 = Light Weight Door with a 4″ drum.
- Door Profile 3 = Heavy Weight Door* with a 6″ drum.
- Door Profile 4 = Light Weight Door with a 6″ drum.
- NOTE: Drum sizes vary by manufacturer.
For Standard Lift Section Doors:
- Drums less than or equal to 5″, use 4″ drum.
- Drums more than 5″, use 6″ drum.
High Lift Door
- Door Profile 5 = Tapered drum with rails that raise to a higher elevation
Vertical Lift Sectional Door
- Door Profile 5 = Tapered Drum with rails raising vertically above the opening.
Set Door Profile
- To enter Set Door Profile mode, press and hold the black button for one second. The UP and DOWN buttons turn a solid color.
- To set Door Profile, press the UP and DOWN buttons. The Learn LED button blinks and beeps as you change the setting.
- The number of Learn LED button blinks indicates which profile you have selected. There is no preset door profile setting.
- Press and release the Black button to set the Door Profile. This process is now complete. Proceed to the Travel Learn mode.
Exiting Door Profile Number Setting: If there is no selection within 4.5 minutes, the Door Profile selection mode will be cancelled with a long beep.
Automatic Force Set Up
Once both the up and down positions have been manually set, the Safety
Reversing Sensors will reconnect and become operational. Then, the opener will
enter a force-sensing operation by automatically moving the door open and
close. The garage door opener will sound an audible and visual alert before
automatically opening and closing the door. The garage door opener will beep
three times, confirming that the Automatic Force Setup completed successfully.
Adjustment is complete.
If you hear one long beep after the door attempts to move, then the Automatic
Force Set Up has not completed successfully. Please start over at step 1.
Test the Safety Reversal System
- With the door fully open, place a 1-1/2″ (3.8 cm) board (or a 2×4 laid flat) on the floor, centered under the garage door.
- Press the remote control push button to close the door. The door MUST reverse when it makes contact with the board.
If the door stops but does not reverse:
- Review the installation instructions provided to insure all steps were followed;
- Repeat Program the Travel (see Adjustment Step 2);
- Repeat the Safety Reversal test. If the test continues to fail, call a trained door systems technician.
Program the Travel
- Press and hold the UP Button until the door is in the desired UP position. 2. Once the door is in the desired UP position, press and release the Adjustment Button. The garage door opener lights will flash twice and the DOWN Button will begin to flash.
- Press and hold the DOWN Button, until the door is in the desired DOWN position.
- Once the door is in the desired DOWN position, press and release the Adjustment Button. The garage door opener lights will flash twice. Program the Travel is now complete. If the garage door opener lights flash 5 times, then programming has timed out and the Travel Limits have not been set. Please restart the Program the Travel process.
Test the Protector System®
- Press the remote control push button to open the door.
- Place the opener carton in the path of the door.
- Press the remote control push button to close the door. The door will not move more than 1″. The garage door opener will not close from a remote if the indicator light in either sensor is off (alerting you to the fact that the sensor is misaligned or obstructed).
Test the Automatic Garage Door Lock
- With the garage door fully closed, the automatic garage door lock bolt should be protruding through the track.
- Open the garage door. The automatic garage door lock should retract before the garage door begins to move.
- Close the garage door. When the garage door reaches the fully closed position, the automatic garage door lock should automatically activate to secure the door. Disengage the automatic garage door lock by sliding the manual release to the open position.
To Open the Door Manually
- Disengage any door locks before proceeding. The door should be fully closed if possible. Pull down on the emergency release handle until a click is heard from the garage door opener and lift the door manually.
- To reconnect the door to the garage door opener, pull the emergency release handle straight down a second time until a click is heard from the garage door opener. The door will reconnect on the next UP or DOWN operation.
114-5858-000 Wi-Fi® is a registered trademark of Wi-Fi Alliance
© 2023 LiftMaster LLC All Rights Reserved
References
Read User Manual Online (PDF format)