AVTECHSMART FRES2100TW 100W LED Fresnel with Zoom User Manual
- June 12, 2024
- AVTECHSMART
Table of Contents
- AVTECHSMART FRES2100TW 100W LED Fresnel with Zoom
- Product Information
- Safety Instructions
- Overview
- Installation
- Securing with a safety cable
- Power connection
- Operation
- DMX Protocol
- Fixture Cleaning
- Troubleshooting
- Technical specifications
- DIMENSION
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AVTECHSMART FRES2100TW 100W LED Fresnel with Zoom
Product Information
The FRES2100TW is a 100W LED fresnel with zoom. It is a powerful and versatile device designed for indoor use only. The fixture provides a high-quality light source with adjustable zoom capabilities.
Safety Instructions
- Be careful with your operations. With a dangerous voltage, you can suffer a dangerous electric shock when touching the wires.
- Avoid looking directly into the light source. Wear protective glasses and other PPE (personal protective equipment) when working on or near the fixture.
- Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.
- Make sure it is grounded when using it. Unplug mains lead before opening the housing.
- Make sure that the power cord is never crimped or damaged by sharp edges.
- Check the fixture and the power cord from time to time.
- Make sure to replace the fuse with another of the same type and rating.
Installation
Before installing the fixture, read the “Safety information” section in the user manual. The fixture should be used in a dry location with adequate ventilation. Ensure that none of the fixture’s ventilation slots are blocked.
To fasten the fixture to a flat surface:
- The surface should be hard, fixed, and flat, oriented at any angle.
- Ensure that the surface and all fasteners used can support at least 10 times the weight of all fixtures and equipment to be installed on it.
- Fasten the fixture securely to the surface.
- If the fixture is installed in a location where it may cause injury or damage if it falls, secure it with a securely anchored safety cable that will hold the fixture if the primary fastening method fails.
For more detailed information and instructions, please refer to the user manual.
Caution!
- Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric shock when touching the wires!
- Avoid looking directly into the light source!
- Wear protective glasses and other PPE (personal protective equipment) when working on or near the fixture.
- Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.Make sure it is grounded when using it!
- Unplug mains lead before opening the housing!
- Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture and the powercord from time to time.
- Make sure to replace the fuse with another of the same type and rating.
- For your own safety, please read this user manual carefully before you initial start-up.
- Follow operating safety precautions and pay attention to warning signs methods and equipment on the user manual.
- Warning! This symbol indicates a hot surface. Certain parts of the housing can become hot during operation. After use, wait for a cool-down period of at least 10 minutes before handling or transporting the device.
- Indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture. IP 20 rating.
- The ambient temperature must always be between -5° C and +45° C.
Every person involved with the installation, operation and maintenance of this device has to
- be qualified
- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire service life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the Internet
$Introduction
Thank you for having chosen FRES2100TW. You will see you acquired a powerful and versatile de-vice. Unpack your item. Before you initial start-up, please make sure that there is no damage caused by transportation. Should there be any, consult your dealer and do not use the device.
Safety Instructions
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. Always disconnect from the mains, when the device is not in use or before cleaning it. Keep away children and amateurs from the device! There are no serviceable parts inside the device. Maintenance and service operations are only to be carried out by authorized dealers.
Overview
Installation
Read ‘Safety information’ before installing the fixture.
The fixture is designed for indoor use only and must be used in a dry location
with adequate ventilation. Ensure that none of the fixture’s ventilation slots
are blocked.
Fasten the fixture to a secure structure or surface. Do not stand it on a
surface or leave it where it can be moved or fall over. If you install the
fixture in a location where it may cause injury or damage if it falls, se-cure
it as directed in this user manual using a securely anchored safety cable that
will hold the fixture if the primary fastening method fails.
Fastening the fixture to a flat surface
The fixture can be fastened to a hard, fixed, flat surface that is oriented at
any angle. Ensure that the sur-face and all fasteners used can support at
least 10 times the weight of all fixtures and equipment to be installed on it.
Fasten the fixture securely. Do not stand it on a surface or leave it where it
can be moved or fall over. If you install the fixture in a location where it
may cause injury or damage if it falls, secure it as directed be-low with a
securely anchored safety cable that will hold the fixture if the primary
fastening method fails.
Mounting the fixture on a truss
The fixture can be clamped to a truss or similar rigging structure in any orientation. When installing the fixture hanging vertically down, you can use an open-type clamp such as a G-clamp. When installing in any other orientation, you must use a half-coupler clamp that completely encircles the truss chord.
To clamp the fixture to a truss:
- Check that the rigging structure can support at least 10 times the weight of all fixtures and equip-ment to be installed on it.
- Block access under the work area.
- Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through both mounting bracket legs and be fastened with a self-locking nut.
- Working from a stable platform, hang the fixture with its clamp on the truss and fasten the clamp se-curely.
- Secure the fixture with a safety cable as directed below.
Securing with a safety cable
Secure the fixture with a safety cable (or other secondary attachment) that is
approved for the weight of the fixture so that the safety cable will hold the
fixture if a primary attachment fails.
Loop the safety cable through the eyebolt in the back of the fixture and
around a secure anchoring point. Do not loop the safety cable around the
fixture’s mounting bracket only, as this will leave the fixture unsecured if
it separates from the bracket.
DMX-512 connection/connection between fixtures
Occupation of the XLR connection:
If you are using controllers with this occupation, you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain. If you wish to connect DMX controllers with other XLR outputs, you need to use adapter cables.
Building a serial DMX chain:
- Connect the DMX-output of the first fixture in the DMX chain with the DMX input of the next fixture. Always connect one output with the input of the next fixture until all fixtures are connected.
DMX-512 connection with DMX terminator:
- For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 resistor connected between pins 2 and 3, which is then plugged into the output XLR socket of the last fixture in the chain.
Caution : At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 resis-tor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
Power connection
Power Requirements
The FRES2100TW luminaire operates on 100 to 240 volts AC (+/- 10%, auto- ranging). The luminaire contains an auto-ranging power supply.
Power linking between fixtures:
The fixture with powercon in and out socket. Connect the power out to the
power in socket in the next fix-ture till all are connected.
Caution : maximum power linking – 8 units.
Connection with the mains:
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection cables as below:
Cable color | Connection | International |
---|---|---|
Brown | Live | L |
Blue | Neutral | N |
Yellow/green | Earth(Ground) |
Operation
The FRES2100TW can operate different modes. In each mode you can run the fixture as a stand alone fixture or in a master/slave confiugration. This next section will detail the differences in the operat-ing modes.
Control Menu Map
MENU | SUB MENU | OPERATION |
---|---|---|
Addr | d001-d512 | RDM/DMX address |
CHnL
| 2CH| ****
Channel mode
3CH
6CH
7CH
Strb| S.01-s.20| Strobe with spead increasing
uL–| u.000-u.255| WW Dimmer
cL–| c.000-c.255| CW Dimmer
Focu| F.000-255| Zoom function
nodE
| nod.0| Dimmer speed 0 (no delay)
nod.1| Dimmer speed 1
nod.2| Dimmer speed 2
nod.3| Dimmer speed 3
nod.4| Dimmer speed 4 (slowest speed)
Id| Id.01-Id.66| ID address setting
tEnP| -25~100| Fixture temperature
MENU| SUB MENU| OPERATION
---|---|---
UErn| | Firmware version
rSEt| yes/no| Reset
pnnF| (1.2~24.0)F| PWM refresh rate adjustment(KHz)
Addressing
- All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture responds to the correct control signals. This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller. The alloca-tion of this starting address is achieved by setting the correct number on the display located on the base of the device.
- You can set the same starting address for all fixtures or a group of fixtures, or make different address for each fixture individually.
- If you set the same address, all the units will start to listen to the same control signal from the same channel number. In other words, changing the settings of one channel will affect all the fixtures simulta-neously.
- If you set a different address, each unit will start to listen to the channel number you have set, based on the quantity of control channels of the unit. That means changing the settings of one channel will affect only the selected fixture.
- In the case of the FRES2100TW, which is 2/3/6/7 channels fixture. If you set, for example, the ad-dress in the 2 channel mode to channel 3, the device will use the channel 3 to 4 for control.
Universal DMX Control
This function allows you to use a universal DMX-512 controller to control the dimmer and strobe. A DMX controller allows you to create unique programs tailored to your individual needs.
RDM control
- The FRES2100TW can communicate using RDM (Remote Device Management) in accordance with ESTA’s American National Standard E1.20-2006: Entertainment Technology RDM Remote Device Man-agement Over DMX512 Networks.
- RDM is a bi-directional communications protocol for use in DMX512 control systems, it is the open stan-dard for DMX512 device configuration and status monitoring.
- The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting ex-isting non-RDM equipment. It allows a console or dedicated RDM controller to send commands to and receive messages from specific fixtures.
- With RDM function, you can set the DMX address of your fixtures remotely. This is especially useful when the device is installed in a remote area.
- Each FRES2100TW has a factory set RDM UID (unique identification number).
DMX Protocol
2 Channels Mode | Function | Function Control |
---|---|---|
CH1 | Dimmer | 000-255: 0-100% dimmer |
CH2 | Zoom | 000-255: zoom function |
3 Channels Mode | Function | Function Control |
--- | --- | --- |
CH1 | WW | 000-255: warm white 0-100% dimmer |
CH2 | CW | 000-255: cold white 0-100% dimmer |
CH3 | Zoom | 000-255: zoom function |
6 Channels Mode | Function | Function Control |
--- | --- | --- |
CH1 | Dimmer | 000-255: 0-100% dimmer |
CH2 | WW | 000-255: warm white 0-100% dimmer |
CH3 | CW | 000-255: cold white 0-100% dimmer |
CH4 | Strobe | 000-255: strobe with speed increasing |
CH5 | Zoom | 000-255: zoom function |
CH6
| ****
Dimmer mode
| 000-005: Menu setting
006-055: Dimmer speed 0 (no delay)
056-105: Dimmer speed 1
106-155: Dimmer speed 2
156-205: Dimmer speed 3
206-255: Dimmer speed 4 (slowest speed)
7 Channels Mode| Function| Function Control
---|---|---
CH1| Dimmer| 000-255: 0-100% dimmer
CH2
| ****
Color temperature
| 0-10: no function
11-255: 2700K – 6000K tunable
CH3| WW| 000-255: warm white 0-100% dimmer
CH4| CW| 000-255: cold white 0-100% dimmer
CH5| Strobe| 000-255: strobe with speed increasing
CH6| Zoom| 000-255: zoom function
CH7
| ****
Dimmer mode
| 000-005: Menu setting
006-055: Dimmer speed 0 (no delay)
056-105: Dimmer speed 1
106-155: Dimmer speed 2
156-205: Dimmer speed 3
206-255: Dimmer speed 4 (slowest speed)
Fixture Cleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend cleaning on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.
To clean the fixture:
- Disconnect the fixture from power and allow it to cool for at least 10 minutes.
- Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pres-sure compressed air.
- Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented tis-sue or cotton swab moistened with glass cleaner or distilled water.
- Check that the fixture is dry before reapplying power.
Fuse Replacement
This fuse is located in a fuseholder next to the MAINS OUT socket on the connections panel. To replace a fuse:
- Disconnect the fixture from power and allow it to cool for at least 10 minutes.
- Unscrew the cap of the fuseholder and remove the fuse. Replace with a fuse of the same size and rating only.
- Reinstall the fuseholder cap before reapplying power.
Troubleshooting
Listed below are a few common problems that you may encounter, with solutions.
The fixture does not work, no light
- Check the connection of power and main fuse. Be sure the external fuse has not blown.
- Measure the mains voltage on the main connector.
Technical specifications
- Model FRES2100TW
- Power supply : AC100-240V, 50/60Hz
- Light source : 100W WW+100W CW tunable LED
- Color temperature: 2700K-6000K tunable
- Color Rendition : Average CRI 95, TLCI 97
- Zoom scale : 25°-65° motorized
- Power connection : PowerCON in&out
- Maximum power linking: 8 units
- Signal connection: 5-pin XLR in&out
- DMX channels : 2/3/6/7 CH
- Control mode : RDM, DMX, Master-slave
- Housing: Colour black, Aluminum
- Size(barn door excluded): 331 x 210 x 345.7mm(13 x 8.3 x 13.6in)
- Package(carton): 448 x 338 x 400mm(17.6 x 13.3 x 15.7in)
- N.W.: 6.6kg(14.5lb)
- Enviroment : IP20
Please note: All information is subject to change without prior notice. 12.05.2022
DIMENSION
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>