AVTECHSMART PANEL150TW Studio LED Panel User Manual
- June 12, 2024
- AVTECHSMART
Table of Contents
AVTECHSMART PANEL150TW Studio LED Panel
- Be sure to read the USER MANUAL carefully before using this product.
- Be sure to keep the USER MANUAL properly for future needs.
- Use this product correctly when you can fully understand the User Manual
Caution!
- Be careful with your operations. With a dangerous voltage you can suffer a dangerous electric shock when touching the wires!
- Avoid looking directly into the light source!
- Wear protective glasses and other PPE (personal protective equipment) when working on or near the fixture.
- Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product’s specification label.Make sure it is grounded when using it!
- Unplug mains lead before opening the housing!
- Make sure that the power cord is never crimped or damaged by sharp edges. Check the fixture and the powercord from time to time.
- Make sure to replace the fuse with another of the same type and rating.
- For your own safety, please read this user manual carefully before you initial start-up.
- Follow operating safety precautions and pay attention to warning signs methods and equip-ment on the user manual.
- Warning! This symbol indicates a hot surface. Certain parts of the housing can become hot during operation. After use, wait for a cool-down period of at least 10 minutes before handling or transporting the device.
- Indoor use only! To prevent risk of fire or shock, do not expose this product to rain or moisture. IP 20 rating.
- The ambient temperature must always be between -5° C and +45° C.
- Every person involved with the installation, operation and maintenance of this device has to
- be qualified
- follow the instructions of this manual
- consider this manual to be part of the total product
- keep this manual for the entire service life of the product
- pass this manual on to every further owner or user of the product
- download the latest version of the user manual from the Internet
Introduction
Thank you for having chosen PANEL150TW. You will see you acquired a powerful and versatile device. Unpack your item. Before you initial start-up, please make sure that there is no damage caused by transportation. Should there be any, consult your dealer and do not use the device.
Safety instructions
This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual. Always disconnect from the mains, when the device is not in use or before cleaning it. Keep away children and amateurs from the device! There are no serviceable parts inside the device. Maintenance and service operations are only to be carried out by authorized dealers.
Installation
Read ‘Safety information’ before installing the fixture.
The fixture is designed for indoor use only and must be used in a dry location
with adequate ventilation. Ensure that none of the fixture’s ventilation slots
are blocked. Fasten the fixture to a secure structure or surface. Do not stand
it on a surface or leave it where it can be moved or fall over. If you install
the fixture in a location where it may cause injury or damage if it falls,
secure it as directed in this user manual using a securely anchored safety
cable that will hold the fixture if the primary fastening method fails.
Fastening the fixture to a flat surface
The fixture can be fastened to a hard, fixed, flat surface that is oriented at
any angle. Ensure that the surface and all fasteners used can support at least
10 times the weight of all fixtures and equipment to be installed on it.
Fasten the fixture securely. Do not stand it on a surface or leave it where it
can be moved or fall over. If you install the fixture in a location where it
may cause injury or damage if it falls, secure it as directed below with a
securely anchored safety cable that will hold the fixture if the primary
fastening method fails.
Mounting the fixture on a truss
The fixture can be clamped to a truss or similar rigging structure in any
orientation. When installing the fixture hanging vertically down, you can use
an open-type clamp such as a G-clamp. When installing in any other
orientation, you must use a half-coupler clamp that completely encircles the
truss chord.
To clamp the fixture to a truss:
- Check that the rigging structure can support at least 10 times the weight of all fixtures and equip-ment to be installed on it.
- Block access under the work area.
- Fold the legs of the mounting bracket together and bolt a rigging clamp securely to the mounting bracket. The bolt used must be M10, grade 8.8 steel minimum. It must pass through both mounting bracket legs and be fastened with a self-locking nut.
- Working from a stable platform, hang the fixture with its clamp on the truss and fasten the clamp securely.
- Secure the fixture with a safety cable as directed below.
Securing with a safety cable
Secure the fixture with a safety cable (or other secondary attachment) that is
approved for the weight of the fixture so that the safety cable will hold the
fixture if a primary attachment fails. Loop the safety cable through the
eyebolt in the back of the fixture and around a secure anchoring point. Do not
loop the safety cable around the fixture’s mounting bracket only, as this will
leave the fix-ture unsecured if it separates from the bracket.
DMX-512 connection/connection between fixtures Occupation of the XLR connection:
If you are using controllers with this occupation, you can connect the DMX- output of the controller di-rectly with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs, you need to use adapter-cables.
Building a serial DMX chain:
Connect the DMX output of the first fixture in the DMX chain with the DMX
input of the next fixture. Always connect one output with the input of the
next fixture until all fixtures are connected.
DMX-512 connection with DMX terminator:
For installations where the DMX cable has to run a long distance or is in an
electrically noisy environment, such as in a discotheque, it is recommended to
use a DMX terminator. This helps in preventing corruption of the digital
control signal by electrical noise. The DMX terminator is simply an XLR plug
with a 120 resistor connected between pins 2 and 3, which is then plugged into
the output XLR socket of the last fixture in the chain.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ω resistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
Power connection
Power Requirements|
The PANEL150TW luminaire operates on 100 to 240 volts AC (+/- 10%, auto-
ranging). The luminaire contains an auto-ranging power supply.
Power linking between fixtures: The fixture with powercon in and out socket.
Connect the power out to the power in socket in the next fixture till all are
connected.
Caution: maximum power linking – 6 units.
Connection with the mains: Connect the device to the mains with the enclosed power supply cable. The occupation of the connection cables as below:
Operation
The PANEL150TW can operate in three different modes. This next section will detail the differences in the operating modes.
Control Menu Map
Default setting in bold.
Control menu
The information menu will appear after the fixture is switched on. In this
menu, the following status is displayed:
Main Menu
Press the MENU button to enter the Main Menu interface.
Addressing
All fixtures should be given a DMX starting address when using a DMX signal so
that the correct fixture responds to the correct control signals. This digital
starting address is the channel number from which the fixture starts to listen
to the digital control information sent out from the DMX controller. The
allocation of this starting address is achieved by setting the correct number
on the display located on the base of the device. You can set the same
starting address for all fixtures or a group of fixtures, or make different
address for each fixture individually. If you set the same address, all the
units will start to listen to the same control signal from the same channel
number. In other words, changing the settings of one channel will affect all
the fixtures simultaneously.
If you set a different address, each unit will start to listen to the channel number you have set, based on the quantity of control channels of the unit. That means changing the settings of one channel will af-fect only the selected fixture. In the case of the PANEL150TW, which is 2/5 channels fixture. If you set, for example, the address in the 2 channel mode to channel 3, the device will use the channel 3-4 for control.
Note: After switching on, the device will automatically detect whether DMX 512 data is received or not. If there is data received at the DMX input, you will see the DMX indicator light in green.
Universal DMX Control
This function allows you to use a universal DMX-512 controller to control the
dimmer and strobe. A DMX controller allows you to create unique programs
tailored to your individual needs.
RDM control
The PANEL150TW can communicate using RDM (Remote Device Management) in
accordance with ESTA’s American National Standard E1.20-2006: Entertainment
Technology RDM Remote Device Management Over DMX512 Networks. RDM is a bi-
directional communications protocol for use in DMX512 control systems, it is
the open standard for DMX512 device configuration and status monitoring. The
RDM protocol allows data packets to be inserted into a DMX512 data stream
without affecting existing non-RDM equipment. It allows a console or dedicated
RDM controller to send commands to and receive messages from specific
fixtures. With RDM function, you can set the DMX address of your fixtures
remotely. This is especially useful when the device is installed in a remote
area. Each PANEL150TW has a factory-set RDM UID (unique identification
number).
Note: Before operation, enable RDM function in Advanced settings.
Rotary Knob function
The knob in the rear panel of the PANEL150TW act as multi-function. Including
rotary control of the dimmer, rotary control of dimmer, up/down/enter
function.
Dimmer function:
- Press the MENU button to enter the main menu.
- Press the UP or DOWN button to select Mode menu and press ENTER.
- Press DOWN menu and select Manual sub menu.
- Press ENTER and select Brightness or Strobe in third menu.
- Rotate the rotary knob to control the dimmer(right stop = maximum output, left stop = zero output), or strobe(right stop = maximum strobe, left stop = no strobe).
Note: Rotary dimmer or strobe function works in information Menu and Mode-Manual menu.
Up, Down, Enter function:
The knob can also act as up, down and enter function.
- Press the MENU button to enter the main menu interface.
- Right rotation = Down, left rotation = Up, press = Enter function.
Set dimmer curves
This function allows you to select preset dimmer curves as well as custom
dimmer curves.
To set preset dimmer curves:
-
Press the MENU button to enter the main menu.
-
Press the UP or DOWN button to select the Dimmer menu and press ENTER.
-
Press the DOWN menu and select the Mode sub-menu.
-
Select the disired dimmer mode.
Custom dimmer curves: -
Press the MENU button to enter the main menu.
-
Press the UP or DOWN button to select the Dimmer menu and press ENTER.
-
Press the DOWN menu and select the Mode sub-menu.
-
Press the UP or DOWN button to select the Custom menu and press ENTER.
-
Adjust fade-in and fade-out time to customize your dimmer curves. Time varies from 150 ms to 2230 ms.
DMX Protocol
2 Channels Mode | Function | Function Control |
---|---|---|
CH1 | WW | 000-255: 0-100% dimmer |
CH2 | CW | 000-255: 0-100% dimmer |
5 Channels Mode | Function | Function Control |
--- | --- | --- |
CH1 | Dimmer | 000-255: 0-100% dimmer |
CH2 | Strobe | 000-255: from slow to fast |
CH3 | WW | 000-255: 0-100% warm white dimmer |
CH4 | CW | 000-255: 0-100% cold white dimmer |
CH5 | Color temperature | 000-255: Color temperature 3200K – 5600K |
Fixture Cleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend clean-ing on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.
To clean the fixture:
- Disconnect the fixture from power and allow it to cool for at least 10 minutes.
- Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pres-sure compressed air.
- Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented tissue or cotton swab moistened with glass cleaner or distilled water.
- Check that the fixture is dry before reapplying power.
Troubleshooting
Listed below are a few common problems that you may encounter, with solutions.
The fixture does not work, no light
- Check the connection of the power and main fuse. Be sure the external fuse has not blown.
- Measure the mains voltage on the main connector.
Technical specifications
Please note: All information is subject to change without prior notice. 30.06.2021
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>