SOLUTIONS PPMNT-1001 Parapet and Rooftop Mounts
Installation Guide
Installation Guide
Parapet and Rooftop Mounts
PPMNT-1001 RFMNT-1001
PPMNT-2001 RFMNT-2001
PPMNT-1001 Parapet and Rooftop Mounts
Copyright
© 2023, Motorola Solutions, Inc. All rights reserved. MOTOROLA, MOTO,
MOTOROLA SOLUTIONS, and the Stylized M Logo are trademarks or registered
trademarks of Motorola Trademark Holdings, LLC and are used under license.
Other names or logos mentioned herein may be the trademarks of their
respective owners. The absence of the symbols ™ and ® in proximity to each
trademark in this document or at all is not a disclaimer of ownership of the
related trademark.
This document has been compiled and published using product descriptions and
specifications available at the time of publication. The contents of this
document and the specifications of the products discussed herein are subject
to change without notice. Motorola Solutions Inc. reserves the right to make
any such changes without notice. Neither Motorola Solutions Inc. nor any of
its affiliated companies: (1) guarantees the completeness or accuracy of the
information contained in this document; or (2) is responsible for your use of,
or reliance on, the information. Motorola Solutions Inc. shall not be
responsible for any losses or damages (including consequential damages) caused
by reliance on the information presented herein.
Motorola Solutions Inc.
motorolasolutions.com
Revision: 1 20230104
Introduction
The PPMNT-1001 and RFMNT-1001 mounts are designed for outdoor use with small-
size pendant cameras, and the PPMNT-2001 and RFMNT-2001 are for outdoor use
with medium-size pendant cameras. The PPMNT1001 and PPMNT-2001 models mount
to parapets, while the RFMNT-1001 and RFMNT-2001 models mount to rooftops or
other smooth horizontal surfaces. All models accommodate pendant cameras that
use 1.5-inch NPT pipe.
The PPMNT-2001 and RFMNT-2001 can be used in applications where mounting and
height clearances of models PPMNT-1001 and RFMNT-1001 are inadequate. Models
PPMNT-2001 and RFMNT-2001 are higher by 9.72 inches (24.69 cm) and the
overhang is increased by 14.77 inches (37.52 cm). The mounts are designed to
swivel within available clearance limits, which adds to the flexibility, easy
maintenance, and usability of the configuration.
Manufactured from aluminum, the mounts include indexing bolts to secure the
arm in position.
Thoroughly familiarize yourself with the information in this manual prior to
installation and operation.
Preparing to Install a Parapet or Rooftop Mount
The hardware to install the mount depends on your installation requirements. The mount has pre-drilled holes for use with 3/8-16 type hardware. (This hardware is not included with the mount.) Use as many of the mounting holes as possible. 3/8-16 type fastening hardware is recommended. Multiple fastening positions facilitate mounting flexibility. For models PPMNT-1001 and PPMNT-2001, mount using a minimum of three fasteners on each side of the mounting plate. For models RFMNT-1001 and RFMNT-2001, mount using a minimum of two fasteners on each side of the mounting base. If necessary to prevent damage from water leakage, you should also have sealant (not supplied) to apply around the bolt holes between the mount and mounting surface.
Important Safeguards and Warnings
Prior to installation and use of this product, observe the following warnings:
- Installation and servicing should only be done by qualified service personnel and conform to all local codes.
- Installation shall be done in accordance with all local and national electrical and mechanical codes utilizing only approved materials.
- Use only installation methods and materials capable of supporting four times the maximum specified load.
- Use stainless steel hardware to fasten the mount to outdoor surfaces.
- To prevent damage from water leakage when installing a mount outdoors on a roof or wall, apply sealant around the bolt holes between the mount and mounting surface.
Thoroughly familiarize yourself with the information in this manual prior to installation and operation.
Installing a Parapet or Rooftop Mount
-
Loosen the nuts holding the brake mounting plate. Loosen the nuts only enough to pull the arm out of
the guide hoops (see Figure 1 ). -
Remove the arm.
-
Install the mount
PPMNT-1001/PPMNT-2001
Install the mounting plate to the inside or the outside of the parapet. Use a minimum of three fasteners on each side of the mounting plate. Depending on the type of parapet construction, install the mounting plate as close to the top of the parapet as possible. If the mounting plate is installed two to five inches from the top of the parapet, you can swing the dome back for maintenance as necessary (the dome will clear the top of the parapet). If necessary to prevent water damage, apply sealant around the bolt holes between the mount and mounting surface.
RFMNT-1001/RFMNT-2001
Install the mounting base to the rooftop or other smooth horizontal surface. Use a minimum of two fasteners on each of the four sides of the mounting base (a minimum total of eight fasteners). If necessary to prevent water damage, apply sealant around the bolt holes between the mount and mounting surface. -
Reinstall the arm; lower the arm through the guide hoops until it stops at the bottom of the mounting plate.
-
Pull the wires through the arm starting from the bottom of the mounting plate; pull the wires out through the threaded opening at the top of the arm.
-
Pull the wires through the dome, and attach the dome to the end of the arm.
-
Make all electrical connections.
-
Move the arm and dome into the desired position.
-
Secure the brake mounting plate against the arm; tighten the nuts on the studs that hold the brake mounting plate in place.
-
To hold the arm in position, tighten the indexing bolts near the center of the brake mounting plate. If desired, drill into the arm through the holes in the brake mounting plate, install the indexing bolts, and tighten.
Important: Do not drill into existing wiring that may be pulled through the arm.
Parapet Wall Mount Outline Dimensions
| A| B| C
---|---|---|---
PPMNT-1001| 25.50 (64.77)| 35.08 (89.10)| 20.42 (51.87)
PPMNT-2001| 37.66 (95.65)| 42.00 (106.68)| 33.00 (83.82)
Note: Values in parentheses are centimeters; all others are inches.
Rooftop Mount Outline Dimensions
| A| B| C
---|---|---|---
RFMNT-1001| 25.50 (64.77)| 35.27 (89.59)| 20.42 (51.87)
RFMNT-2001| 37.66 (95.65)| 42.19 (107.16)| 33.00 (83.82)
Note: Values in parentheses are centimeters; all others are inches.
Specifications
MODELS
PPMNT-1001| Parapet mount for small-size pendant cameras; mounts to inside or
outside of parapet.
RFMNT-1001| Rooftop or smooth horizontal surface mount for small-size pendant
cameras.
PPMNT-2001| Same as PPMNT-1001 except overhang clearance and height
accommodate medium-size pendant cameras.
RFMNT-2001| Same as RFMNT-1001 except overhang clearance and height
accommodate medium-size pendant cameras.
Mechanical
Positioning Adjustment| 360°
Mounting Method
| Secure to mounting surface with 3/8-16 type fastening hardware (not
supplied). Multiple fastening positions facilitate mounting flexibility.
PPMNT-1001/PPMNT-2001| Mount using a minimum of six fasteners
RFMNT-1001/RFMNT-2001| Mount using a minimum of eight fasteners
Dome Mounting| Dome screws directly into mount
GENERAL
Maximum Load | 45 lb (20.41 kg) approximate |
---|
Effective Projected Area
(EPA)
| PPMNT-1001/RFMNT-1001| ~133 square inches
PPMNT-2001/RFMNT-2001| ~177 square inches
Construction| Aluminum
Finish| Powder Coat: RAL 9003
Environment| Outdoor
Unit Weight
| PPMNT-1001| 9.30 lb (4.22 kg)
RFMNT-1001| 20.19 lb (9.16 kg)
PPMNT-2001| 10.38 lb (4.71 kg)
RFMNT-2001| 22.53 lb (10.22 kg)
Shipping Weight
| PPMNT-1001| 15 lb (6.80 kg)
RFMNT-1001| 33 lb (14.95 kg)
PPMNT-2001| 17 lb (7.70 kg)
RFMNT-2001| 35 lb (15.85 kg)
For More Information
For additional product documentation, visit
motorolasolutions.com.
Technical Support
Contact Technical Support at
motorolasolutions.com/support.
Read User Manual Online (PDF format)