CHAMPION POWER EQUIPMENT 201176 9000 Watt Tri Fuel Inverter with CO Shield User Manual
- June 12, 2024
- CHAMPION POWER EQUIPMENT
Table of Contents
201176
9000 Watt Tri Fuel Inverter with CO Shield
User Manual
201176 9000 Watt Tri Fuel Inverter with CO Shield
PARTS INCLUDED
DANGER
MOVE GENERATOR OUTDOORS
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains
carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
ONLY use OUTSIDE and far away from windows, doors, and vents.
WARNING
Read the ENTIRE operator’s manual to become familiar with the features of
this product before operation. This QuickStart Guide IS NOT a substitute for
the Operator’s Manual.
Failure to operate the product correctly could result in damage to the
product, personal property or cause serious injury or death.
NOTICE
Keep all objects at least 5 feet (1.5 m) from generator. Heat from the muffler
and exhaust gas can ignite combustible materials.
SET UP
-
Remove Hardware. Assembly > Remove Shipping Support Hardware
-
Attach wheel kit. Assembly > Install Wheel Kit
-
Connect the battery. Assembly > Connect the Battery.
Cut cable tie on each side of battery connector. -
Add oil. Assembly > Add Engine Oil.
Recommended: 10W-30, up to 37.2 fl. oz. (1100 ml) DO NOT overfill. -
Move the generator outdoors.
ONLY USE OUTSIDE AND FAR AWAY FROM WINDOWS, DOORS, AND VENTS. -
Add fuel – Gasoline, Propane (LPG), or Natural Gas (NG)
Assembly > Add Fuel -
DO NOT plug in any electrical devices.
NEVER START OR STOP THE GENERATOR WITH ELECTRICAL DEVICES CONNECTED OR TURNED ON! -
8a. Starting the Engine: Gasoline
Electric Start
1. Turn fuel select dial to “GASOLINE OPERATION” position.
2. Move the choke lever to the “CHOKE” position.
3. Press and hold the ignition switch to the “START” position.
4. Move the choke lever to the “RUN” position. Manual Start
1. Turn fuel select dial to “GASOLINE OPERATION” position.
2. Move the choke lever to the “CHOKE” position.
3. Pull the starter cord.
4. Move the choke lever to the “RUN” position. 8b. Starting the Engine: Propane (LPG) and Natural Gas
Electric Start
1. Open the propane tank or natural gas valve.
2. Turn fuel select dial to “PROPANE OPERATION” or “NATURAL GAS OPERATION” position.
3. Move the choke lever to the “CHOKE” position.
4. Press the ignition switch to the “START” position for 2-3 seconds.
5. Move the choke lever to the “RUN” position.
6. Press and hold the ignition switch to the “START” position.
7. If engine does not start, wait 10 seconds, then repeat step 6. Manual Start
1. Open the propane tank or natural gas valve.
2. Turn fuel select dial to “PROPANE OPERATION” or “NATURAL GAS OPERATION” position.
3. Move the choke lever to the “CHOKE” position.
4. Pull the starter cord 2-3 times until you feel some combustion pulses.
5. Move the choke lever to the “RUN” position.
6. Pull the starter cord. -
Plug in. Operation > Connecting Electrical Loads.
Champion Power Equipment, Inc.,
Santa Fe Springs, CA 90670, USA/EE. UU.
4083-M-OP
REV 20230321