CHAMPION POWER EQUIPMENT 201176 9000 Watt Tri Fuel Inverter with CO Shield User Manual

June 12, 2024
CHAMPION POWER EQUIPMENT

CHAMPION POWER EQUIPMENT 201176 9000 Watt Tri Fuel Inverter with CO Shield -
Logo 201176 9000 Watt Tri Fuel Inverter with CO Shield
User Manual

201176 9000 Watt Tri Fuel Inverter with CO Shield

PARTS INCLUDED

CHAMPION POWER EQUIPMENT 201176 9000 Watt Tri Fuel Inverter with CO Shield -
PARTS

DANGER

CHAMPION POWER EQUIPMENT 201176 9000 Watt Tri Fuel Inverter with CO Shield -
Icon 2

MOVE GENERATOR OUTDOORS
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
ONLY use OUTSIDE and far away from windows, doors, and vents.
WARNING
Read the ENTIRE operator’s manual to become familiar with the features of this product before operation. This QuickStart Guide IS NOT a substitute for the Operator’s Manual.
Failure to operate the product correctly could result in damage to the product, personal property or cause serious injury or death.
NOTICE
Keep all objects at least 5 feet (1.5 m) from generator. Heat from the muffler and exhaust gas can ignite combustible materials.

SET UP

  1. Remove Hardware. Assembly > Remove Shipping Support HardwareCHAMPION POWER EQUIPMENT 201176 9000 Watt Tri Fuel Inverter with CO Shield - Remove Hardware

  2. Attach wheel kit. Assembly > Install Wheel Kit

  3. Connect the battery. Assembly > Connect the Battery.
    Cut cable tie on each side of battery connector.CHAMPION POWER EQUIPMENT
201176 9000 Watt Tri Fuel Inverter with CO Shield - Connect the
battery

  4. Add oil. Assembly > Add Engine Oil.
    Recommended: 10W-30, up to 37.2 fl. oz. (1100 ml) DO NOT overfill.CHAMPION
POWER EQUIPMENT 201176 9000 Watt Tri Fuel Inverter with CO Shield - Add Engine
Oil

  5. Move the generator outdoors.
    ONLY USE OUTSIDE AND FAR AWAY FROM WINDOWS, DOORS, AND VENTS.CHAMPION POWER
EQUIPMENT 201176 9000 Watt Tri Fuel Inverter with CO Shield - generator
outdoors

  6. Add fuel – Gasoline, Propane (LPG), or Natural Gas (NG)
    Assembly > Add FuelCHAMPION POWER EQUIPMENT 201176 9000 Watt Tri Fuel
Inverter with CO Shield - Add fuel

  7. DO NOT plug in any electrical devices.
    NEVER START OR STOP THE GENERATOR WITH ELECTRICAL DEVICES CONNECTED OR TURNED ON!CHAMPION POWER EQUIPMENT 201176 9000 Watt Tri Fuel Inverter with
CO Shield - DO NOT plug in

  8. 8a. Starting the Engine: Gasoline
    Electric Start
    1. Turn fuel select dial to “GASOLINE OPERATION” position.
    2. Move the choke lever to the “CHOKE” position.
    3. Press and hold the ignition switch to the “START” position.
    4. Move the choke lever to the “RUN” position.CHAMPION POWER EQUIPMENT
201176 9000 Watt Tri Fuel Inverter with CO Shield - Starting the
Engine Manual Start
    1. Turn fuel select dial to “GASOLINE OPERATION” position.
    2. Move the choke lever to the “CHOKE” position.
    3. Pull the starter cord.
    4. Move the choke lever to the “RUN” position.CHAMPION POWER EQUIPMENT
201176 9000 Watt Tri Fuel Inverter with CO Shield - Manual
Start 8b. Starting the Engine: Propane (LPG) and Natural Gas
    Electric Start
    1. Open the propane tank or natural gas valve.
    2. Turn fuel select dial to “PROPANE OPERATION” or “NATURAL GAS OPERATION” position.
    3. Move the choke lever to the “CHOKE” position.
    4. Press the ignition switch to the “START” position for 2-3 seconds.
    5. Move the choke lever to the “RUN” position.
    6. Press and hold the ignition switch to the “START” position.
    7. If engine does not start, wait 10 seconds, then repeat step 6.CHAMPION
POWER EQUIPMENT 201176 9000 Watt Tri Fuel Inverter with CO Shield - Electric
Start Manual Start
    1. Open the propane tank or natural gas valve.
    2. Turn fuel select dial to “PROPANE OPERATION” or “NATURAL GAS OPERATION” position.
    3. Move the choke lever to the “CHOKE” position.
    4. Pull the starter cord 2-3 times until you feel some combustion pulses.
    5. Move the choke lever to the “RUN” position.
    6. Pull the starter cord.CHAMPION POWER EQUIPMENT 201176 9000 Watt Tri Fuel
Inverter with CO Shield - Manual Start 1

  9. Plug in. Operation > Connecting Electrical Loads.

Champion Power Equipment, Inc.,
Santa Fe Springs, CA 90670, USA/EE. UU.
4083-M-OP
REV 20230321