ETHAN ALLEN 09-8033 Turnbull Shaded Wall Sconce Instruction Manual
- June 12, 2024
- ETHAN ALLEN
Table of Contents
ETHAN ALLEN 09-8033 Turnbull Shaded Wall Sconce
Product Information
- Product Name: Turnbull Wall Sconce
- Model Numbers: 09-8033 / 09-8034
- Weight: 1.8 lbs. / 0.8 kg
- Recommended Installation by a Licensed Electrician
- Rated Bulb Wattage should not be exceeded
- Flammable materials should be kept away from the bulb
- Internal wiring should not be opened or altered
- Requires an electrical junction box in the ceiling for installation
- Power should be turned off at the circuit breaker before installation
- All included parts should be located before disposing of packaging materials
- Tools Required for Installation: Screwdrivers, Wire Cutters, Wire Connectors, Electrical Tape, Pliers, Adjustable Wrench
- Lightbulb(s) not included (except where required by State of California Title 20)
Product Usage Instructions
- SHUT OFF THE MAIN ELECTRICAL SUPPLY AT FUSE BOX/CIRCUIT BREAKER.
- Remove all parts from the carton. Do not throw away any parts.
- Remove the Mounting Plate (A) from Backplate (E) by loosening Screws (B).
- Affix Mounting Plate (A) to Junction Box with Mounting Screws (D) provided.
- Make proper electrical connections as described in steps 6-9.
- A LICENSED ELECTRICIAN IS RECOMMENDED.
- Attach the BARE WIRE from the fixture to the GROUND JUNCTION BOX WIRE from the OUTLET JUNCTION BOX. Fasten each together with a WIRE NUT (K) by twisting the connector in a clockwise direction and wrap the connection with electrical tape. Make sure that no wire strands are exposed. If your OUTLET JUNCTION BOX DOES NOT have a GROUND WIRE, be sure to insert the GROUND SCREW (H) into the Mounting Plate (J), marked as GND, facing front and wrap the fixture’s bare GROUND WIRE around the GROUND SCREW. Tighten the screw to clamp the GROUND WIRE between the GROUND SCREW (H) head and Mounting Plate (J). IT IS IMPERATIVE THAT THE JUNCTION BOX IN YOUR HOME BE PROPERLY GROUNDED!
- Connect the NEUTRAL FIXTURE WIRE to the NEUTRAL JUNCTION BOX WIRE. Fasten each together with a WIRE NUT (K) by twisting the connector in a clockwise direction and wrap the connection with electrical tape. Make sure that no wire strands are exposed.
- Connect the HOT FIXTURE WIRE to the HOT JUNCTION BOX WIRE. Fasten each together with a WIRE NUT (K) by twisting the connector in a clockwise direction and wrap the connection with electrical tape. Make sure that no wire strands are exposed. DO NOT REVERSE THE HOT AND NEUTRAL CONNECTIONS OR SAFETY WILL BE COMPROMISED.
SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS. READ THESE INSTRUCTIONS COMPLETELY BEFORE
STARTING.
We strongly recommend that all direct-wired lighting products be installed by
a licensed electrician. Two people may be required for installation. DO NOT
EXCEED the rated bulb wattage. Keep flammable materials away from bulb. This
light fixture is shipped with all internal wiring intact. Do not open the
product or alter the wiring in any manner.
Installation requires an electrical junction box in the ceiling sufficient to
support the weight of the light fixture. This fixture weighs 1.8 lbs./ 0.8 kg.
WARNING: Be certain that the power to the electrical junction box is
turned off at the circuit breaker before installation. Turning the power off
at a light switch is not sufficient to prevent electrical shock.
CAUTION: Prior to installation, locate ALL INCLUDED PARTS before
disposing of packaging materials.
TOOLS REQUIRED FOR INSTALLATION
- Screwdrivers 3. Wire Cutters 5. Wire Connectors
- Electrical Tape 4. Pliers 6. Adjustable Wrench
Note: Lightbulb(s) are not included, except where required by State of California Title 20. See light fixture for bulb specification. Additional wiring supplies may be required.
Parts Included (refer to figure):
Part| Qty.| Description| Part| Qty.|
Description| Part| Qty.| Description| Part| Qty.|
Description
A| 1| Mounting Plate| C| 3| Wire Nut| E| 1| Backplate| G| 1| Socket ring
B| 3| Screws| D| 2| Mounting screw| F| 1| Socket| H| 1| Shade
| | | | | | | | | I| 1| Ground Screw
Assembly Procedure (refer to figure)
-
SHUT OFF THE MAIN ELECTRICAL SUPPLY AT FUSE BOX/CIRCUIT BREAKER.
-
Remove all parts from the carton. Do not throw away any parts.
-
Remove the Mounting Plate (A) from Backplate (E) by loosening Screws (B).
-
Affix Mounting Plate (A) to Junction Box with
Mounting Screws (D) provided. -
Make proper electrical connections described in steps 6-9.
-
A LICENSED ELECTRICIAN IS RECOMMENDED.
-
Attach the BARE WIRE from the fixture to the GROUND JUNCTION BOX WIRE from the
OUTLET JUNCTION BOX. Fasten each together with a WIRE NUT (K) by twisting the connector in a clockwise direction and wrap the connection with electrical tape. Make sure that no wire strands are exposed. If your OUTLET JUNCTION BOX DOES NOT have a GROUND WIRE, be sure to insert the GROUND SCREW (H) into the Mounting Plate (J), marked as “GND,” facing front and wrap the fixture’s bare GROUND WIRE around the GROUND SCREW. Tighten the screw to clamp the GROUND WIRE between GROUND SCREW (H) head and Mounting Plate (J). IT IS IMPERATIVE THAT THE JUNCTION BOX IN YOUR HOME BE PROPERLY GROUNDED! -
Connect the NEUTRAL FIXTURE WIRE to the NEUTRAL JUNCTION BOX WIRE. Fasten each together with a WIRE NUT (K) by twisting the connector in a clockwise direction and wrap the connection with electrical tape. Make sure that no wire strands are exposed.
-
Connect the HOT FIXTURE WIRE to the HOT JUNCTION BOX WIRE. Fasten each together with a WIRE NUT (K) by twisting the connector in a clockwise direction and wrap the connection with electrical tape. Make sure that no wire strands are exposed. DO NOT REVERSE THE HOT AND NEUTRAL CONNECTIONS OR SAFETY WILL BE COMPROMISED.
-
Put the lamp Backplate (E ) onto the Mounting Plate (A) and secure with Screws (B).
-
Remove Socket ring (G), put the shade (H) onto the socket (F) and secure with Socket ring (G).
-
Install proper lightbulb into Socket (F).
Care and Cleaning
- Wipe with a soft dry cloth.
- AVOID cleaners, scouring pads, etc.
After troubleshooting, if the lighting fixture still does not work, contact your local Ethan Allen Design Center. SAVE THESE INSTRUCTIONS
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>