Danfoss VACON NXP System Drive User Guide

June 1, 2024
Danfoss

Danfoss-logo

Danfoss VACON NXP System Drive

Danfoss-VACON-NXP-System-Drive-product-image

Product Information

Specifications:

  •  Partner for reliability and performance in heavy industries
  • Standardized and pre-tested drive solutions
  • Modular design with pull-out feature for quick setup and maintenance
  • Proven AC drive technology for heavy industry applications

Product Usage Instructions

  • Step 1: Setting up Process Data
    Enter all standard process data needed for the drive system to operate as desired, such as main network type, frequency, voltage, and ambient temperature.

  • Step 2: Configuration Adjustment
    After entering process data, configuration will start automatically. Adjust parts to meet specific needs by checking dimensions (height x length x depth).

  • Step 3: Finalizing Setup
    Review technical description listing all specifications to ensure alignment with requirements.

Frequently Asked Questions (FAQ)

  • Q: What are the typical applications for this product?
    A: This product is suitable for various heavy industries including Marine, Metals, and Pulp and Paper. Typical applications include cranes, hoists, thrusters, metal plane lines, melting and casting, rolling mill applications, conveyors, sectional drives, and debarking drums.

  • Q: What are the key benefits of using this product?
    A: The key benefits include complete drive solutions, premium quality, time and cost savings, standardized products fitting all application needs, minimized lifetime cost, modular design for quick setup and maintenance, short setup time, and easy training for onsite engineers.

Selection Guide l VACON® NXP System Drive
Save costs and improve reliability – the easy way

Danfoss-VACON-NXP-System-Drive- \(1\)

The best partner for reliability and performance

Customers in heavy industries, such as Marine, Metals and Pulp and Paper, need drive systems that excel in terms of reliable performance. If you can rely on your system, it leaves you with more time and money to spend on optimizing the rest of the application.

  • You can now be sure to receive a drive system that is unmatched in terms of quality and ready in a shorter space of time than ever before. That’s because we have changed our production approach to bring it into line with what customers are after. VACON® NXP System Drive ensures that you receive an excellent level of quality and service, each and every time.
  • In the system drives business, communication between partners is the key to successful end result. Large-scale projects often feature many different components which are reliant upon communication on both sides to avoid technical problems anywhere down the line.

Driven by drives

  • Our ability to work around the challenges our customers face everyday, regarding efficiency and cost savings, is the reason why we have reached where we are. By choosing Danfoss

  • Drives, you can be sure to receive a top-class drive system – nothing else will do. We also won’t compete with system integrators
    for projects, unlike many other drive suppliers. This enables an atmosphere of mutual trust with our network of system integrators and end-users.

  • Complex solutions   made simple

It’s essential that you receive a solution with a level of quality that’s as consistent as it is excellent. VACON NXP System Drive provides complex solutions which are simplified through standardization, resulting in a product that will easily integrate into the process. This doesn’t prevent you from getting the exact solution you need – we can tailor some elements of the system in order to meet your requirements.

Why choose VACON® NXP System Drive?

  • Cost savings
    • Traditionally, the design of a project-based enclosure accounts for up to 35% of the total cost.
    • With VACON® NXP System Drive, this is reduced to around 5%.
  • Focus on drives
    • We concentrate on drives so you can concentrate on the rest of the application.
    •  Danfoss Drives is always a non-competing partner for system integrators on projects.
  • Quality as standard
    • Standardized and pre-tested solutions.
    • We support our customers by supplying them with complete drive systems.
  • Proven track record
    • VACON® NXP Common DC Bus technology has been the ideal choice for drive systems for a number of years.

VACON® NXP System Drive – quality as standard

  • Reliability is key
    VACON® NXP System Drive brings what customers need above all else – consistent and reliable quality guaranteed. We excel in delivering verified and tested solutions that combine VACON® AC drives, DC bus components and options. No need to worry about waiting for technical data, documentation or piloting – we’ve done all that before it reaches your premises.

  • Quick installation
    Aside from the quality delivered, VACON® NXP System Drive is also easy to adapt. Engineered sections slot in alongside each other, allowing you to arrange integrated transport splits to save space. Alternatively, you can add extra transport sections to speed up installation. All larger modules have slide-out mechanics that facilitate setup and maintenance. This also enables late module delivery, which  can be helpful if the system is to be installed in a harsh environment. All sections are grouped depending on their functionality, making it possible to plan each installation phase exactly how you wish.

  • Cost efficiency
    Besides the peace of mind that comes with stress-free installation and setup, you’ll also save a lot of time and money.

Key benefits

  • Complete drive solutions

    • Standardized products which fit all your application needs
    • Modules can be delivered closer to start of the operation
    • Minimized lifetime cost
  • Premium quality

    • Industry-leading VACON® NXP and VACON® Common DC bus solutions
    • Safe, tested and verified design
    • Comprehensive documentation available with each delivery
  • Save on time and cost

    • Modular design equipped with pull out feature for quick setup and maintenance
    • Short setup time
    • Easy to train onsite engineers
      Danfoss-VACON-NXP-System-Drive- \(16\)
  • This is because the setup is essentially formulated when you order it, meaning system integrators can get on with designing the rest of the application. The fact that the drive system’s setup is uniform also means that it’s far easier to provide spare parts.

Safety and service means a longer lifecycle

  • A complex and wide-ranging solution is not one you want to have to replace, which is why VACON® NXP System Drive is built to last. One of the cornerstones of the relationship with our partners is a commitment to drives performance that goes far beyond the point of purchase.
  • Items such as busbar systems and high/low power devices are separated into individual compartments, away from each other. This means that,  if things go wrong, the problem is compartmentalized and doesn’t cause widespread failure. The fact that VACON® NXP System Drive is easy to maintain also makes it safer.
  • Service engineers are immediately familiar with the way the system is set up, meaning they can get straight to the focal point.

Proven AC drive technology for heavy industry

  • Still need a reason to choose us? How about the fact that VACON® NXP drives have been leading the way in the industry for the past decade. Aside from frequency converter units, we can also deliver software and common DC bus components, which combine to make your personal solution. VACON® NXP Common DC bus technology has been the choice for our drive system customers for many years already – VACON NXP® System Drive simply ensures an optimal version of this solution, consistently and quickly.

Typical applications

  • Marine and Offshore

    •   Cranes and Hoists

    • Thrusters

    • Deck machinery

  • Metals

    • Metal plane lines
    • Melting and casting
    • Rolling mill applications
  • Pulp and Paper

    • Conveyors
    • Sectional drives
    • Debarking drums

Danfoss-VACON-NXP-System-Drive- \(17\)

Danfoss-VACON-NXP-System-Drive- \(4\)

VACON® NXP System Drive configurator

  • Setting up VACON® NXP System Drive couldn’t be easier – our online configuration tool guides you through the whole design process while providing you with the necessary documentation.
  • This is all achieved in a number of simple steps:
    1. You enter all the standard process data you will need for the drive system to work as you want it to e.g. main network type, frequency, voltage, ambient temperature etc. Once you have selected all these, configuration will start automatically.
    2. Now you can play around with the parts to ensure that they meet your needs. The dimensions (height x length x depth) are all listed so that you can ensure the setup fits into the space you have set aside for the system.
    3. When everything is setup and is ready to go, VACON® Configurator will automatically provide you with the documentation you need for the initial system setup, including a technical description listing all the specifications.

As a user of VACON® NXP System Drive configuration tool, you will have your own profile page which lists all your configurations, drafts and technical history. This allows you to easily keep track of your settings so that you don’t have to spend time looking around for mislaid papers. Danfoss-VACON-
NXP-System-Drive- \(7\) Danfoss-VACON-NXP-System-Drive-
\(8\) Danfoss-VACON-NXP-System-Drive-
\(9\)

Key benefits

  • Engineering process is cut to a minimum
  • Prevents human mistakes from occurring during configuration
  • Preferred configurations can be saved in customer profiles
  •  Easy and efficient way to try out implementation options

Available sections

Auxiliary Device Section (ADS)
The auxiliary device section includes the common line-up controls.
This section can be customized for all application and segment needs. There is one ADS size available.
As standard the ADS section has the following equipment:

  • Indication of the mains status (fault, pre-charging and ON)
  • Auxiliary power supply 24 V, 5 A
  • Auxiliary transformer, 2500 VA
  • 1- phase supply (in bottom of cabinet)
  • Terminals for control and monitoring

As pre-engineered standard options, we can provide the following:

  • Emergency stop CAT0 (+PES)

  • Emergency stop CAT1 (+PED)

  • Insulation fault sensor (+PIF)

  • Arc protection (+PAP)*

  • Cabinet heater (+ACH)

  • Cabinet light (+ACL)

  • Auxiliary voltage transformer 4000 VA (+AT4)

  • Auxiliary voltage 110 VAC (+AT1)

  • Auxiliary power supply 24 V, 10 A (+ADC)

  • Cabling from the top (+CIT)

  • UL approved design and components (+NAR)

  • Customer specific option (+CSO)

+PAP will have sub units in selected sections if needed, please refer to the circuit diagrams.

ADS type Dimensions, W x H x D [mm]
ADS_400 400 x 2000 x 605
ADS_600 600 x 2000 x 605
ADS_800 800 x 2000 x 605

Main Incoming Section (MIS)

The main incoming section includes the main incoming device. The main incoming device and size is dependent on the required current of the complete line-up.
As standard the MIS section has the following equipment:

  • Main incoming device, load switch
  • Mains connections
  • Emergency disconnect push button
  • Digital multi instrument with field bus connection

As pre-engineered standard options we can provide the following:

  • Cabling from the top (+CIT)
  • Earth switch (+ILE)*
  • Current transducers (+ITR)
  • UL approved design and components (+NAR)
  • Arc protection (+PAP)
  • Cabinet heater (+ACH)
  • Cabinet light (+ACL)
    +ILE requires an additional section.
MIS type Input current Dimensions, W x H x D [mm]
MIS_630 630 A 400 x 2000 x 605
MIS_1000 1000 A 600 x 2000 x 605
MIS_1250 1250 A 600 x 2000 x 605
MIS_1600 1600 A 600 x 2000 x 605
MIS_2500 2500 A 600 x 2000 x 605
MIS_3200 3200 A 800 x 2000 x 605
MIS_4000 4000 A 800 x 2000 x 605
MIS_5000 5000 A 800 x 2000 x 605

Danfoss-VACON-NXP-System-Drive- \(10\)

Non-regenerative Front-end Section (NFS)

The non-regenerative front-end section (NFS) includes one or multiple NXN units from the VACON® product family. The NXN is a non-regenerative supply unit that can be utilized in
6-pulse, 12-pulse,18-pulse and 24-pulse systems.
As standard the NFS section includes the following:

  • The NXN unit(s)
  • Chokes
  • Terminals for control and indication signals
  • DC fuses for the supply unit
  • AC fuses for the filter

As pre-engineered standard options, we can provide the following:

  • UL approved design and components (+NAR)
  • Arc protection (+ADU)
  • Cabinet heater (+ACH)
  • Cabinet light (+ACL)

Danfoss-VACON-NXP-System-Drive- \(189

Active Front-end Section (AFS)
The active front-end section includes an LCL-filter and an NXA unit from the VACON product family. The active front-end provides low THD(I) and several units can be connected in parallel providing full or reduced redundancy.
As standard the AFS sections include the following:

  • LCL-filter
  • The NXA unit
  • Control unit
  • Pre-charging components
  • Terminals for control and indication signals
  • DC fuses for the supply unit
  • AC fuses for the filter

As pre-engineered standard options we can provide the following

  • UL approved design and components (+NAR)
  • Arc detection (+ADU)
  • Cabinet heater (+ACH)
  • Cabinet light (+ACL)
AFS type Frame size Dimensions, W x H x D [mm]
AFS_9 FI9 800 x 2100 x 605*
AFS_10 FI10 800 x 2100 x 605*
AFS_13 FI13 1400 x 2100 x 605*
--- --- ---

Danfoss-VACON-NXP-System-Drive- \(11\)

Available sections

Inverter Unit Section (IUS) drive sizes FR4-FR8

The inverter unit section (IUS) includes one or several smaller NXI drives
from the VACON® product family. The inverter units are all VACON® NXP drives.
As standard the IUS section includes the following:

  • Input fuses (DC fuses)
  • The NXI drive(s)
  • Control box (integrated into the module)
  • Terminals for control and indication signals

As pre-engineered standard options we can provide the following:

  • dU/dt (+ODU)
  • Common mode filter (+OCM)
  • Input switch, DC-disconnect (+ISD)
  • Arc detection (+ADU)
  • Motor fan control (+AMF)
  • Motor heater feeder (+AMH)
  • Mechanical break control (+AMB)
  •  Top cabling (+COT)
  • UL approved design and components (+NAR)
  • Cabinet heater (+ACH)
  • Cabinet light (+ACL)

Danfoss-VACON-NXP-System-Drive- \(221\)

  • Only option board and fieldbus options
  • Top exit +400 mm can be shared between two sections

Danfoss-VACON-NXP-System-Drive- \(12\)

Inverter Unit Section (IUS) drive sizes FI9-FI14

The inverter unit section (IUS) includes the largest NXI drives from the VACON® product family. The inverter units are all VACON® NXP drives.
As standard the IUS section includes the following:

  • Input fuses (DC fuses)
  • The NXI drive
  • Service platform/module removal
  • Outlet for power (for PC etc.)
  • Control section and fixed external terminals, 70 pcs

As pre-engineered standard options we can provide the following:

  • dU/dt (+ODU)
  • Common mode filter (+OCM)
  • Input switch with charging (+ISC)
  • Arc detection (+ADU)
  • Motor fan control (+AMF)
  • Motor heater feeder (+AMH)
  • Mechanical break control (+AMB)
  • Top cabling (+COT)
  • UL approved design and components (+NAR)
  • Cabinet heater (+ACH)
  • Cabinet light (+ACL)

Danfoss-VACON-NXP-System-Drive- \(221\)

Danfoss-VACON-NXP-System-Drive- \(5\) Danfoss-VACON-NXP-System-Drive- \(15\)

Danfoss Drives
Danfoss Drives is a world leader in variable speed control of electric motors. We aim to prove to you that a better tomorrow is driven by drives. It is as simple and as ambitious as that.

  • We offer you unparalleled competitive edge through quality, application-optimized products targeting your needs – and a comprehensive range of product lifecycle services.
    You can rely on us to share your goals. Striving for the best possible performance in your applications is our focus. We achieve this by providing the innovative products and application know-how required to optimize efficiency, enhance usability, and reduce complexity.
    From supplying individual drive components to planning and delivering complete drive systems; our experts are ready to support
    you all the way.

We draw on decades of experience within industries that include:

  • Chemical
  • Cranes and Hoists
  • Food and Beverage
  • HVAC
  • Lifts and Escalators
  • Marine and Offshore
  • Material Handling
  • Mining and Minerals
  • Oil and Gas
  • Packaging
  • Pulp and Paper
  • Refrigeration
  • Water and Wastewater
  • Wind
  • You will find it easy to do business with us. Online, and locally in more than 50 countries, our experts are never far away, reacting fast when you need them.
  • Since 1968, we have been pioneers
    in the drives business. In 2014, Vacon and Danfoss merged, forming one of the largest companies in the industry. Our AC drives can adapt to any motor technology and we supply products in a power range from 0.18 kW to 5.3 MW.

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to Al tract marks lee this materiel ide property of the especial companies. Danton and he Danfoss los type are tradesman’s of Anton’s AS. Ad ages reserved.

DKDD.PB.915.A1.02
© Copyright Danfoss Drives | 2016.01
EtherNet/IP™ and DeviceNet™ are trademarks of ODVA, Inc.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals