EVA LOGIK ZW36M Z-Wave Mini Smart Plug
Product Information
- Specification:
- Input: 125VAC 60Hz; Frequency: 908.42
- MHz; Loading: 15A 1875W RESISTIVE OR GENERAL PURPOSE 5A MAX 625W TUNGSTEN 1/3 HP; Indoor use in dry location
- LED Indicator: Blue: Light status indicator Blue: ADD / Inclusion Purple: Remove / Exclusion Red: Network Failure / Over-temperature Warning
Features:
- Z-Wave control on/off.
- Z-Wave controlled AC outlet for standard incandescent lighting, CFL/LEDs, fans or small appliances(1875W Resistive Max).
- Grounded 3-wire power connection for safety.
- Remembers and restores on/off status after power failure.
- Built-in Z-Wave Plus signal repeater to extend network range.
- S2 security and 700 Z-Wave chip for reliable wireless communication.
- Work with all certificated Z-Wave controllers.
Product Usage Instructions
- Plug the device you want to control into the Z-Wave Smart plug controlled outlet. Note: Plug directly into the outlet, do not use with power strip.
- Your device may need to be within 100 feet of the controller to be included. If so, include the device to the network within 10 feet of the controller and relocate it to the desired position in your home. Be sure to refresh the network if the device is included in this manner.
- To add the device to the Z-Wave network:
- Press the program button once for manual inclusion.
- Press the program button three times for Z-Wave network configuration.
- Press the program button twice and hold it for 10 seconds to reset the device.
- Scan the QR code on the packaging box to add the device to the network.
- To remove the device from the Z-Wave network, press the program button and then press and hold it for 5 seconds.
- Parameter settings for Z-Wave network configuration can be adjusted as needed.
Specification
- Input: 125VAC 60Hz
- Frequency: 908.42 MHz
- Loading: 15A 1875W RESISTIVE OR GENERAL PURPOSE 5A MAX 625W TUNGSTEN 1/3 HP
Indoor use in dry location
Features
- Z-Wave control on/off.
- Z-Wave controlled AC outlet for standard incandescent lighting, CFL/LEDs, fans or small appliances(1875W Resistive Max).
- Grounded 3-wire power connection for safety.
- Remembers and restores on/off status after power failure.
- Built-in Z-Wave Plus signal repeater to extend network range.
- S2 security and 700 Z-Wave chip for reliable wireless communication.
- Work with all certificated Z-Wave controllers.
WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other Z
-Wave-certified devices from other manufacturers and/or other applications.
All non-battery-operated nodes within the network will act as repeaters
regardless of vendor to increase the reliability of the network.
This Device supports Lifeline (association group 1) supporting 1 node for
lifeline communication.
Group 1 must be assigned the Node ID of the primary controller where
unsolicited notifications will be sent. The Z-Wave controller should set this
association automatically after inclusion. Lifeline association only supports
the “Device Reset Locally” function.
Adding Device To Z-Wave Network for QR CODE
Notes:
-
Plug the device you want to control into the Z-Wave Smart plug-controlled outlet.
NOTE: Plug directly into the outlet, do not use with power strip. -
Your device may need to be within 100 feet of the controller to be included. If so, include the device to the network within 10 feet of the controller and relocate
it to the desired position in your home. Be sure to refresh the network if the device is included in this manner.
Z-Wave Network Configuration
Adding Device To Z-Wave Network
- Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
- Once the controller is ready to add your device, press the Manual/ Program button on the smart plug 3 times quickly. The blue LED will flash quickly.
Auto-add mode: LED will flash within 30 seconds after the first plug. Now, you have completed control to turn your fixture ON / OFF according to groups, schedules and interactive automation programmed by your controller. If your Z-Wave certified controller features remote access, you can control your fixture from your mobile devices. Again: If you have issues with pairing / including, please move the device as close as possible to the hub and try again–you can move to your final location when completed. Note: If the manual button doesn’t light up after pressing 3 times, please reset the device: click the button twice quickly then hold it at least 10 seconds.
This operation could be done when manual control is functional–single press can turn on/off the lamp.
To Remove The Device
- Follow the instructions for your Z-Wave-certified controller to remove a device from the Z-Wave network.
- Once the controller is ready to remove your device, press the manual/program button on the smart plug 3 times quickly.
To Return The Device To Factory Defaults
- Manual: Click the button twice quickly then hold it at least 10 seconds.
- Host reset: Remove it from hub, the device will be restore to factory default.
Association Group
(LED flashes twice when the configuration parameter changed.)
Support 2 groups, each group max support 5 devices
Group 1 lifeline
Group 2 Left outlet send basic set.
Parameter Settings
LED Indicator
This parameter can access you to choose the LED indicator to be on when the
switch (light) is on/off, or LED indicator remains on/off all times. (LED
flashes twice when the configuration parameter changed.)
- Operation: quickly press 6x: change parameter
- Parameter =1, size =1 byte,
- value=00(default) — LED is On when switch(light) is On.
- value=01— LED is On when the switch(light) is Off.
- value=02 — LED is disabled
Auto Turn-Off Timer
This parameter can access you to set a timer to make the switch turn off
automatically after the switch turns on.The numberentered as value corresponds
to number of minutes. Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
— Parameter =2, Size=4,Value: 0– 65535(minutes);
Value=0(default) disable — turn off the outlet.
Auto Turn-On Timer
This parameter can access you to set a timer to make the switch turn on
automatically after the switch is turned on.The number entered as value
corresponds to number of minutes. Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changes.) — Parameter
=4, Size=4, Value: 0– 65535(minutes); Value=0(default) disable — turn on the
outlet
Restores state after power failure
This parameter can access you to set the switch to be on/off after power
failure.(LED flashes twice when the configuration parameter changed.)
Operation: Quickly press the button 10 times (Please note: the switching of
each value is in order, quickly press on the button 10 times will switch once.
- eg: Switching from value 0 to value 2 needs 2 switching. )
- Parameter=6, Size=1
- Value=0 — The switch is off regardless of the state prior to power failure. Value=1 — The switch is on regardless of the state prior to power failure. Value=2(default) — This switch will be return to state prior to the power failure after power is restored.
- Adjust LED brightness (quickly press 8x: change Parameter.)
- (Green LED flashes twice to confirm the setting is successful.)
- Parameter=7, Size=1,
- Value=0 — Bright
- Value=1 — Medium
- Value=2 — Low (default.)
Command Class Information
GRNERIC DEVICE CLASS: 0x10 – SWITCH BINARY
SPECIFIC DEVICE CLASS: 0x00 – NOT_USED
COMMANDCLASS:
- 0x5E – ZWAVEPLUS_INFO
- 0x25 – SWITCH_BINARY
- 0x70 – CONFIGURANTION
- 0x85 – COMMAND_CLASS_ASSOCIATION
- 0x8E – COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION 0x59 – COMMAND_CLASS_ASSOCIATION_GRP_INFO
- 0x55 – COMMAND_CLASS_TRANSPORT_SERVICE
- 0x86 – COMMAND_CLASS_VERSION
- 0x72 – COMMAND_CLASS_MANUFACTURER_SPECIFIC 0x5A – COMMAND_CLASS_DEVICE_RESET_LOCALLY
- 0x87 – COMMAND_CLASS_INDICATOR
- 0x73 – COMMAND_CLASS_POWERLEVEL
- 0x9F – COMMAND_CLASS_SECURITY_2
- 0x6C – COMMAND_CLASS_SUPERVISION
- 0x7A – COMMAND_CLASS_FIRMWARE_UPDATE_MD
Warranty
Our Products warrant this product to be free from manufacturing defects for a period of one year from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or per-mit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state.
FCC
FCC / IC
This device complies with part 15 of the FCC and Industry Canada license-
exempt RSS standard(s). Operation is subjected to the following two
conditions:
- This device may not cause harmful interference, (2) This device must accept any interference received, including interference that may cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment.
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio / TV technician for help.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Important note: To comply with the FCC RF exposure compliance requirements, no change to the antenna or the device is permitted. Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user’s authority to operate the device.
CAUTION – PLEASE READ!
This device is intended for installation in accordance with the National
Electric Code and local regulations in the United States, or the Canadian
Electrical Code and local regulations in Canada If you are unsure or
uncomfortable about performing this installation consult a qualified
electrician.
WARNING
RISK OF FIRE / RISK OF ELECTRICAL SHOCK / RISK OF BURNS TO REDUCE THE RISK OF
ELECTRIC SHOCK, THIS PRODUCT HAS A GROUNDING TYPE PLUG THAT HAS A THIRD
(GROUNDING) PIN. THIS PLUG WILL ONLY FIT INTO A GROUNDING-TYPE POWER OUTLET.
IF THE PLUG DOES NOT FIT INTO THE OUTLET, CONTACT A QUALIFIED ELECTRICIAN TO
INSTALL THE PROPER OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY.
CONTROLLING APPLIANCES:
CAUTION: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT
- DO NOT EXCEED RATINGS
- DO NOT USE TO CONTROL ANY DEVICE
WHERE UNINTENDED OPERATION COULD
CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
MEDICAL EQUIPMENT
Please DO NOT use this switch to control Medical or Life Support equipment.
Z-Wave devices should never be used to control the On / Off status of Medical
and / or Life Support equipment.
CONTROLLING APPLIANCES
Please exercise EXTREME CAUTION when using Z-Wave devices to control
appliances. Reason being is that the appliance you want to control may be in a
separate room and if unintentional behavior occurs (such as adevice turning on
or off – either intentionally via schedules, or unintentionally via network
error) this event may lead to a hazardous condition. For these reasons, please
note the following suggestions:
- Do not include Z-Wave devices in Groups or Scenes if they control appliances.
- Do not use Z-Wave devices to control electric heaters or any other appliances which may present a hazardous condition due to unattended, unintentional, or automatic power control.
Read User Manual Online (PDF format)