Assembly Instructions
Item No: 4830/4832
start here
-
Find a clear area in which you can work.
-
Unpack fixture and glass from carton.
-
Carefully review instructions prior to assembly.
-
Prepare mounting strap (A) by threading the two long mounting screws
(B) into the back of the mounting strap. The side of the mounting strap that the head screw is on, is the front -Drawing 1
Be sure the holes into which the screws are threaded match the spacing of holes (D) in the backplate (C) -
Attach mounting strap (A) to junction box (J) using two screws (E) NOT PROVIDED
-
Fixture can now be wired
-
To mount fixture, slip the two mounting screws (B) through the two mounting holes (D) in the backplate (C)
-
While holing the fixture in place, thread the two barrel knobs (F) on to the end of the mounting screws (B), and tighten
TTACHING PLUG TO FIXTURE
Note:fixture can be wired directly to the wall without plug using IS-18
- To attach corded plug (PC) to the fixture, first remove the plastic plug (P) from the bottom of the backplate (C) – See Drawing 2.
- Next slip grommet (G) over cord (PC) and slip the end of the cord through the hole in the bottom of backplate (C). Slip enough wire through to tie a loose knot in the cord to act as a strain relief.
- Connect black wire to live plug lead
- Connect both white wires to neutral plug lead
- Now slide grommet along wire and push into hole in bottom of backplate to protect cord.
- Fixture is ready for installation. Please follow appropriate instructions for mounting your fixture
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY
ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW
WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL
DRAWING 1 – GLASS INSTLLATION
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
NOTE: fixture should be lamped prior to glass installation.
- To install glass, first remove decorative knobs with studs (2) – see Drawing 2.
- Slip glass (1) into glass fitter (3). Now thread decorative knobs (2) with studs removed earlier, back into side of fitter. Making sure the stud engages the glass neck (N).
- Tighten knobs equally until snug.
- To adjust the arms (AR), to an angle of your liking. Loosen the “H” key (HK), located at the arm joints, approximately 1-1/2 turns or until the teeth, at the joint, can be disengaged – see Drawing 2.
- Rotate arm (AR) up or down to the desired angle and then tighten the “H” key to secure the arm.
- NO T E: that the arm can also pivot to the right or left at the canopy joint. (CJ).
I.S. 18 wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY
ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW
WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR
CODE REQUIREMENTS
wiring instructions
Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – – – see Drawings 2 or 3.
-
Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
-
Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially. -
Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
Flush Mount Fixtures For positive grounding in a 3-wire electrical
system, fasten the fixture ground wire (E) (typically copper or green plastic
coated) to the fixture mounting strap (M) with the ground screw (S) – see
Drawing 1.
Note: On straps for screw supported fixtures, first install the two
mounting screws in strap. Any remaining tapped hole may be used for the ground
screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under
the head of the ground screw (S) on fixture mounting strap (M) and connect to
the loose end of the fixture ground wire directly to the ground wire of the
building system with appropriately sized twist-on connectors – see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal –
see Drawing 3.
33000 Pin Oak Parkway Avon Lake,
OH 44012 800.446.5539
440.653.5500hinkley.com