steinel XLED home 2 Sensor LED Spotlight Instruction Manual
- June 12, 2024
- STEINEL
Table of Contents
- XLED home 2 Sensor LED Spotlight
- About this document
- General safety precautions
- XLED home 2/XLED home 2 XL
- Electrical installation
- Installation
- Function
- Operation/maintenance
- Disposal
- Declaration of Conformity
- Manufacturer’s Warranty
- Technical specifications
- Troubleshooting
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
XLED home 2 Sensor LED Spotlight
Instruction Manual
XLED home 2
XLED home 2 XL
XLED home 2 SL
XLED home 2 Connect
XLED home 2 Sensor LED Spotlight
About this document
Please read carefully and keep in a safe place.
– Under copyright. Reproduction either in whole or in part only with our
consent.
– Subject to change in the interest of technical progress.
– All product dimensions in mm.
Symbols
** Hazard warning!
Reference to other information in the document.
Note:**
Diagrams without captions apply to all versions.
General safety precautions
**** Disconnect the power supply before attempting any work on the unit.
- Installing the LED floodlight involves work on the mains voltage supply; installation must thereforebe carried out professionally in accordance with the applicable national wiring regulations and electrical operating conditions (DE-VDE 0100, AT-ÖVE/ÖNORM E 8001-1, CH-SEV 1000).
- The LED floodlight must be positioned so that it is not expected that anybody can stare into the light for any prolonged period from a distance of less than 0.3 m.
- The floodlight enclosure heats up when the light is on. Only adjust the angle of the LED panel once it has cooled down.
- Do not install the LED floodlight on (normally) flammable surfaces.
XLED home 2/XLED home 2 XL
XLED home 2 SL
XLED home 2 Connect
Proper use
– LED floodlight suitable for wall mounting outdoors.
– Fully swivelling LED panel.
– Can be used on its own or interconnected with other floodlights.
XLED home 2/XLED home 2 XL
– Wired interconnection.
– Operation via control dial.
XLED home 2 Connect
– Wireless interconnection (<100 m).
– Operation via Smart Remote app.
Master versions
– The sensor-switched LED floodlight contains an infrared motion detector.
Movement triggers lights, alarms and many other devices. With the fully
swivelling panel, the LED floodlight can be used at home to provide perfect
illumination for lighting up property, or commercially for lighting up
business premises. In conjunction with the opal cover, this extremely
efficient technology provides wide-area lighting.
Models
– XLED home 2/XLED home 2 XL
– XLED home 2 SL
– XLED home 2 Connect
Package contents for master versions (Fig. 3.1)
Package contents for slave version (Fig. 3.2)
Adjustment range for floodlight head and sensor-switched master
(Fig. 3.3/3.4/6.2/6.3/6.6)
Adjustment range for slave floodlight head (Fig. 3.5/3.6/6.2)
Product dimensions, master (Fig. 3.7/3.8)
Product dimensions, slave (Fig. 3.9/3.10)
Product components, master (Fig. 3.11)
A LED panel
B Enclosure
C Wall mount
D Sensor unit
E Time setting (XLED home 2/XLED home 2 XL)
F Twilight setting (XLED home 2/XLED Home 2 XL)
Product components, slave (Fig. 3.12)
A LED panel
B Enclosure
C Wall mount
Electrical installation
• Switch OFF power supply. (Fig. 4.1)
Connecting the mains power supply lead
The supply lead is a 2 or 3-core cable:
L = phase conductor (usually black, brown or grey)
L’ or ↓ = phase conductor (usually black, brown or grey), in master/master or
master/slave mode only. Mains supply lead is used as connection lead for
switching output.
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/ yellow)
Note:
The protective-earth conductor need not be connected for this product.
Wiring diagram, master/slave (Fig. 4.2)
Wiring diagram, master/master (Fig. 4.3)
Wiring diagrams, slave (Fig. 4.4)
Wiring diagram, XLED home 2 Connect (Fig. 4.5)
Important:
Incorrectly wired connections will produce a short circuit later on in the LED
floodlight or your fuse box. In this case, you must identify the individual
conductors once again and reconnect them.
The light source of this LED floodlight cannot be replaced. If the light
source needs to be replaced (e.g. at the end of its service life), the
complete LED floodlight must be replaced.
Installation
-
Check all components for damage.
-
Do not use the product if the LED floodlight is damaged.
-
Select an appropriate mounting location, taking the reach and motion detection into consideration.
(Fig. 5.1/5.2/5.3) -
Align the LED floodlight. (Fig. 5.4)
The most reliable way to detect movement is given by mounting the LED floodlight to point across the direction in which people walk and by making sure no obstacles (e.g. trees, walls etc.) interrupt the line of sensor vision. (Fig. 5.2/5.3)
Mounting procedure
-
Switch OFF power supply. (Fig. 4.1)
-
Undo retaining screw. (Fig. 5.5)
-
Detach enclosure (B) from wall mount (C). (Fig. 5.6)
-
Detach plug-in terminal from wall mount. (Fig. 5.7)
-
Mark drill holes. (Fig. 5.8)
-
Drill holes and fit ground plugs. (Fig. 5.9)
-
Fit sealing plug. (Fig. 5.10)
– Power supply lead, concealed (Fig. 5.11)
– Power supply lead, surface-mounted, with spacers (Fig. 5.12) -
Connect conductors.
– XLED home 2/XLED home 2 XL (Fig. 5.13)
An additional external load can be connected to N und L’/.
– XLED home 2 Connect/XLED home 2 SL (Fig. 5.14) -
Connect plug-in terminal. (Fig. 5.15)
-
Fit enclosure onto wall mount. (Fig. 5.16)
-
Screw in locking screw. (Fig. 5.17)
-
Switch ON power supply. (Fig. 5.17)
-
Make settings ➜ “6. Function“
Function
XLED home 2/XLED home 2 XL
XLED home 2 SL
Factory settings
Time setting (E): 8 seconds
Twilight setting (F): 2000 lux, (daytime mode)
Time setting (Fig. 6.1/E)
The time you want the LED floodlight to stay on for (main light) is infinitely
adjustable from approx.
8 seconds to a maximum of 35 minutes. Any movement detected before this time
elapses will restart the timer.
– Control dial set to + = longest time, approx. 35 minutes
– Control dial set to – = approx. 8 seconds
Twilight setting (Fig. 6.1/F)
The LED floodlight’s chosen response threshold can be infinitely varied from
approx. 2 to 1000 lux.
– Control dial set to = daylight operation (independent of ambient brightness)
– Control dial set to = night-time operation (approx. 2 lux)
The control dial must be turned to when adjusting the detection zone and
performing the functional test in daylight.
Note:
When setting the detection zone, we recommend selecting the shortest time.
Note:
After the LED floodlight switches OFF, it takes approx. 1 second before it is
able to start detecting movement again. The LED floodlight will only switch ON
in response to movement once this period has elapsed.
XLED home 2 Connect
Factory settings
Twilight setting: 2000 lux, daytime mode, lux teach
Time setting: 5 seconds
Reach setting/adjustment
The detection zone can be optimised to suit requirements.
Sensor unit
– Sensor unit swivels through 180°. (Fig. 6.3)
– Sensor unit tilts through 90°. (Fig. 6.6)
Adhesive shroud (Fig. 6.4)
The film shroud can be used for masking out any number of lens segments to
limit reach as required. Inadvertent triggering is ruled out or the sensor can
be targeted to watch over danger spots (Fig. 6.5).
Other information:
Floodlight adjustment range (Fig. 6.2)
Setting functions
– Setting via control dial (XLED home 2)
– Setting via Smart Remote app (XLED home 2 Connect)
Note:
The settings last selected on the control will be used.
Smart Remote app
To configure the LED floodlight via smartphone or tablet, you must download
the STEINEL Smart Remote app from your app store. You will need a Bluetooth-
capable smartphone or tablet.
Additional functions only via the
Android
| iOS
---|---
http://www.steinel-professional.de/SmartRemote/iOS/|
http://www.steinel.de/contact
Smart Remote app:
– Twilight setting 2 – 2000 lux, daytime mode, lux teach, time teach
– Time setting 5 s – 60 min
– ON / OFF times based on time of day
– Night economy mode
– Reach setting based on sensitivity
– Group interconnection and naming lights / groups
– Manual override 4h ON / 4h OFF
– Password protection
The functions of the LED floodlight can be set via smartphone or tablet.
Bluetooth interconnection is only possible via smartphone or tablet.
Note:
After the LED floodlight switches OFF, it takes approx. 1 second before it is
able to start detecting movement again. The LED floodlight will only switch ON
in response to movement once this period has elapsed.
The XLED home 2 Connect has an internal clock for time-based activation and
deactivation. This automatically synchronises with the clock of the connected
smartphone via the Smart Remote app each time a Bluetooth connection is
established.
To ensure correct function following an interruption in the LED floodlight’s
power supply, it must be re-connected via the Smart Remote app. The internal
clock is re-synchronised with the smartphone clock.
Operation/maintenance
The LED floodlight is not suitable for burglar alarm systems as it is not tamperproof in the manner prescribed for such systems. Weather conditions may affect the way the LED floodlight works.Strong gusts of wind, snow, rain and hail may cause the light to come ON when it is not wanted because the sensor is unable to distinguish between sudden changes in temperature and sources of heat. The detector lens may be cleaned with a damp cloth if it gets dirty (do not use cleaning agents).
Disposal
Electrical and electronic equipment, accessories and packaging must be
recycled in an environmentally compatible manner.
Do not dispose of electrical and electronic equipment as domestic waste.
EU countries only:
Under the current European Directive on Waste Electrical and Electronic
Equipment and its implementation in national law, electrical and electronic
equipment no longer suitable for use must be collected separately and recycled
in an environmentally compatible manner.
Declaration of Conformity
STEINEL Vertrieb GmbH hereby declares that the XLED home 2 Connect radio equipment type conforms to Directive 2014/53/EU. The full wording of the EU Declaration of Conformity is available for downloading from the following Internet address: www.steinel.de
Manufacturer’s Warranty
This STEINEL product has been manufactured with utmost care, tested for proper
operation and safety and then subjected to random sample inspection. Steinel
guarantees that it is in perfect condition and proper working order. The
warranty period is 5 years and starts on the date of sale to the consumer. We
will remedy defects caused by material flaws or manufacturing faults. The
warranty will be met by repair or replacement of defective parts at our own
discretion. The warranty shall not cover damage to wear parts, damage or
defects caused by improper treatment or maintenance.
Further consequential damage to other objects shall be excluded. Claims under
the warranty will only be accepted if the unit is sent fully assembled and
well-packed with a brief description of the fault, a receipt or invoice (date
of purchase and dealer’s stamp) to the appropriate Service Centre.
Service:
Our Customer Service Department will repair faults not covered by warranty or
after the warranty period. Please send the product well-packed to your nearest
Service Centre.
5 YEAR MANUFACTURER’S WARRANTY
Technical specifications
| XLED Home 2| XLED Home 2 XL| XLED Home 2 Connect| XLED Home 2 SL
---|---|---|---|---
Dimensions
(H xWxD)| 218 x 180 x 161| 240 x 180 x 161| 218 x 180 x 161| 181 x 180 x 161
OutpuVefficiency| 14 W / 106 IriVW| 20 W / 106 Nn/1A/| 13.5 W / 109 /NW| 13 W
/ 111 NNW
LLrnhous flint / brightness| 1484 Im| 2120 In| 1472 In| 1443 hi
Power consumption| 0.55 W| 0.55 W| 0.35 W| –
Weight| 0.575 kg| 0.620 kg| 0.575 kg| 0.480 kg
Area Mtn-Slated| Front view 283.1 an’ Side view 113 cm”| Front New 316.2 cm’
Side New 115 an’| Front New 283.1 cm’ Side New 113cm’| Front view 274.1 cm’
Side New 86.3 cm”
Mails ascent| 79 mA| 103 rnA| 69 mA| 66 mA
Power factor| 0.77| 0.85| 0.86| 0.86
Additional swit- thing capacity
XLED home 2 XLED home 2 XL| Incandescent / halogen tamp load 1000 W
Fluorescent-lamp electronic batasts 430 W
Fluorescent lamps. tncorrected 500 VA
Fluorescent lamps. saies-corrected 9:0 VA
Fluorescent larrps. parallel-corrected 500 VA
Low-voltage halogen tamps 10:0 VA
LED<2W 16W
2 W<LED<BW 64W
LED> 8W 64W
Capacitive load BB if
Colour tempaattre| 3000 K (warm white)
Colour rendering index| Ra 2 80
Supply voltage| 220-240 -V / 50/60 Hz
Sensor system| Passive infrared
Reach| max. 10 m
Angle of coverage| 180°
Time setting| 8 s – 35 mil (XLED home 2 Connect 5 s -60 min)
Twilight setaig| 2-20001w
IP /
protection class| IP44 / II
Bluetcoth
frequency| | 2.4-2.48 GHz|
Bluetcoth trans- mitts power| | 5 dBm/3 mW|
Troubleshooting
Malfunction | Cause | Remedy |
---|---|---|
LED floodlight without power | ■ Fuse has blown, not switched ON. break in |
wiring
■ Short circuit| ■ New fuse. turn on power switch.
check wiring with voltage tester
■ Check connections
Sensor-switched LED floodlight will not switch ON| ■ Twilight setting in
night-time mode during daytime operation
■ Mains switch OFF
■ Fuse blown
■ Detection zone not correctly adjusted| ■ Reset
■ Switch ON
■ Replace fuse. check connection if necessary
■ Readjust
Sensor-switched LED floodlight will not switch OFF| ■ Continued movement
within the detection zone| ■ Check zone and readjust if necessary or apply
shroud
Sensor-switched LED floodlight keeps switching ON and OFF| ■ Animals moving in
detection zone| ■ Tilt sensor higher or fit shrouds to target sensor: adjust
detection zone or fit shrouds
Sensor-switched LED floodlight switches ON when it should not| ■ Wind is
moving trees and bushes in the detection zone
■ Cars in the street are detected
■ Sudden temperature changes due to weather (wind, rain, snow) or air expelled
from fans. open windows
■ Sensor-switched LED floodlight swaying (moving). resulting. for example.
from gusts of wind or heavy precipitation| ■ Change detection zone
■ Change detection zone
■ Adjust detection zone or install in a different place
■ Fit sensor-switched LED floodlight to a firm surface
LED floodlight is now shown in the Bluetooth listing| ■ Incorrect region
selected| ■ Settings
• Region EU/Region US
Forgotten password?| | ■ After entering wrong password: °Reset password”
button; switch power supply OFF and back ON again within ’10 minutes; then re-
enter password
App won’t start| ■ Location is not activated| ■ Activate location in
smartphone settings
Settings for LED floodlight are greyed out| ■ LED floodlight is not declared
as group master (slave mode)| ■ Set master floodlight
■ Declare LED floodlight as master
No Bluetooth LED floodlight found| ■ LED floodlight is not in reach
■ Bluetooth is deactivated on smartphone| ■ Check whether Bluetooth is
activated on smartphone or reduce distance to the product
■ Re-start search
No connection being set up from smartphone to LED floodlight| ■ Smartphone too
close to device
■ Smartphone not compatible with app
■ App version not up to date| ■ Distance to LED floodlight at least 1.5 m
■ Use different smartphone
■ Update Smart Remote app in app store
STEINEL Vertrieb GmbH
Dieselstraße 80-84
33442 Herzebrock-Clarholz
Tel: +49/5245/448-188
www.steinel.de
Contact
www.steinel.de/contact
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>