TAYLOR 5296652 Digital Folding K Type Thermocouple with Replaceable Probe User Manual

October 30, 2023
TAYLOR

TAYLOR 5296652 Digital Folding K Type Thermocouple with Replaceable Probe

The 5296652 Digital Folding K-Type Thermocouple is a highly accurate temperature reading device that can be used in multiple environments. The thermocouple is easy to use and has a replaceable probe for added convenience. It also features a backlight function, LCD error messages, and a low battery warning. The unit operates on two AAA batteries and has an IPX7 waterproof rating.

Product Thermocouple Probe Replacement

To replace the K-type thermocouple probe, follow these steps:

  1. Unfold the probe to the open position.
  2. Turn screw cap counterclockwise to loosen and remove.
  3. Gently pull the probe in an outward direction to remove.
  4. Insert the new probe, aligning the + and – polarity symbols.
  5. Replace screw cap and turn clockwise to tighten.

Product Battery Installation

The thermocouple operates on 2 AAA batteries (included). To install batteries:

  1. Remove any plastic wrap from the batteries before proceeding.
  2. Loosen the screws on the battery compartment cover on the back of the thermocouple and remove the cover.
  3. Install 2 AAA batteries into the battery compartment according to the + and – polarity symbols in the battery compartment.
  4. Replace the battery compartment cover and tighten the screws.

Do not use batteries of different brands or types together, or new and old batteries together, as this can result in venting, leakage, and rupture and may cause personal injury. Please recycle or dispose of batteries correctly per local regulations.

Product Storage and Cleaning

The Digital Folding Thermocouple should be kept away from objects that continuously generate high heat for long periods of time to prevent overheating. The unit should not be immersed in water, as doing so will cause damage to internal components and void the warranty. If liquid is spilled on it, dry it immediately with a soft, lint-free cloth. The unit is not dishwasher safe. Clean the battery contacts and those of the device prior to battery installation.

Thank you

Thank you for purchasing a Taylor® Digital Folding K-Type Thermocouple. Please read this instruction manual carefully before use. Keep these instructions handy for future reference. Please remember to keep the unit away from children and do not use it for safety related  applications.

THERMOCOUPLE PROBE REPLACEMENT

To replace the K-type thermocouple probe, unfold the probe to open position. Turn screw cap counterclockwise to loosen and remove. Gently pull probe in an outward direction to remove. Insert new probe, aligning the “+” and “-” polarity symbols. Replace screw cap, turn clockwise to tighten.

FUNCTIONS

DIGITAL FOLDING THERMOCOUPLE PROBE FUNCTION
To turn the unit on, unfold the probe to an open position (between a 45° -180° degree angle). A motion sensor within the unit will re-illuminate the back-light, pick up or gently shake the thermometer to activate. The unit will continuously display temperatures for up to 10 minutes. After that, the unit will automatically shut off to preserve battery life. Or, to turn off manually, fold the probe to a closed position.

  1. Placing stress on the probe may cause breakage.
  2. After measuring high temperatures, the probe may remain HOT for a while. Allow the probe to cool before touching.
  3. Use caution while handling the probe to avoid injury. Keep probe out of reach of children.
    The probe may be damaged if used to measure a temperature that exceeds the specification of the measurement temperature range.
    To avoid electric shock and thermometer damage, do not measure a live circuit where the voltage exceeds 24V AC RMS or 60V CD with the thermocouple probe.

°F OR °C MODE
To switch between ‘°F’ and ‘°C’, unfold probe to open position, rotate unit left to right three times in a row. Or, loosen screws on the battery compartment cover, remove the cover and press ºF/ºC button

BACKLIGHT FEATURE
The backlight will activate for 15 seconds when the unit is in the open position.

LCD ERROR MESSAGES
The thermocouple incorporates visual diagnostic messages as follows:

‘Hi’ or ’Lo’ is displayed when the temperature being measured is outside of the measurement range. ‘bAt’ indicates a low battery warning. Replace both batteries at the same time.

‘”Er3″ is displayed when the entire unit has been exposed to ambient temperature below 32ºF (0ºC) or above 122ºF (50ºC). Allow approximately 30 minutes for the unit to stabilize back to working room temperature.

BATTERY INSTALLATION

The thermocouple operates on 2 AAA batteries (included).

  1. Remove any plastic wrap from the batteries before proceeding.
  2. Loosen the screws on the battery compartment cover on the back of the thermocouple and remove the cover.
  3. Install 2 “AAA” batteries into the battery compartment according to the “+” and “-” polarity symbols in the battery compartment.
  4. Replace the battery compartment cover and tighten the screws.
    CAUTION: When batteries of different brand or type are used together, or new and old batteries are used together, some batteries may be over-discharged due to difference of voltage or capacity. This can result in venting, leakage, and rupture and may cause personal injury.
  • NOTE: Please recycle or dispose of batteries correctly per local regulations.
  • WARNING: Batteries may pose a choking hazard. Do not let children hand batteries. Keep batteries away from children. If swallowed, seek medical attention immediately
  • PRECAUTION: Do not dispose of the unit or batteries in fire, as the batteries inside this unit may explode or leak. Remove the batteries if the product will not be used for along period of time. Remove used batteries promptly. Clean the battery contacts and also those of the device prior to battery installation.

STORAGE & CLEANING

Take care when cleaning the thermocouple, using only a soft cloth or cotton swab with water or medical alcohol, and allow the thermocouple to fully dry before using it. Do not submerge any part of the thermocouple. The thermocouple should be stored at room temperature between -4 to +140°F (-20 to +60°C).

Specifications

Item Digital Folding K-Type Thermocouple
Probe Measurement Range -40°F to 500°F (-40°C to 260°C)
Operating Range 32 to122°F (0 to 50°C)
Resolution 0.1°F (0.1°C)
Probe Accuracy ±1% of reading or 1°F (1°C)
Battery Life Typically 40 hours, minimum 30 hours continuous use
Batteries 2 AAA batteries (included)
Display LCD 1.57×0.75 inch (40x19mm)
Dimensions 6.42×1.93×1.06 inch (163x49x26.9mm)
Probe length 3.3 inches (8.382cm)
IPX7 Waterproof Rating When the battery door is properly closed and the probe

is
properly attached
EMC/RFI| Readings may be affected if the unit is operated within a radio
frequency electromagnetic field strength of approximately 3 volts
per meter, but the performance of the instrument will not be
permanently affected.

EMC/RFI
Readings may be affected if the unit is operated within a radio frequency electromagnetic field strength of approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.

WARNING: DO NOT keep the unit too close to objects that continuously generate high heat (such as a hot plate) for long periods of time. This may cause the unit to overheat.

CARE AND PRECAUTIONS

  1. Always read instructions thoroughly to ensure that you have the full benefit of all the unit’s features.
  2. Keep thermometer and probe out of reach of all children.
  3. DO NOT immerse unit in water, as doing so will cause damage to internal components and void the warranty. If you spill liquid on it, dry it immediately with a soft, lint-free cloth. The unit is not dishwasher safe. Damage will void warranty.
  4. DO NOT clean the unit with an abrasive or corrosive material. This may scratch the plastic parts and corrode the electronic circuits.
  5. DO NOT subject the units to excessive force, shock, dust, temperature or humidity. This may result in malfunction, shorter electronic life span, damaged battery and distorted parts.
  6. DO NOT operate or store the unit in high temperature or humidity conditions. The heat or moisture may interfere with the unit’s internal components. Store the unit at temperatures between -4 and +140°F (–20 and +60°C).
  7. DO NOT tamper with the unit’s internal components. Doing so will invalidate the warranty on the unit and may cause damage. The unit contains no user-serviceable parts.
  8. This unit operates on 2 AAA batteries. Always purchase the correct size and grade of battery most suitable for the intended use. Always replace both batteries at the same time; do not combine old and new batteries. Do not mix Alkaline, carbon-zinc (standard) or Nickel-Cadmium (rechargeable) batteries.

Warranty

Two Year Limited Warranty
Taylor warrants this product to be free from defects in materials or workmanship for two (2) years (excluding batteries) for the original purchaser from date of original purchase. It does not cover damages or wear resulting from accident, misuse, abuse, commercial use, or unauthorized adjustment and/or repair. If service is required, do not return to distributor. For service, call between 7:30 AM and 4:30 PM, Mountain Standard Time, Monday through Friday. To assist us in servicing you, please have the model number and date of purchase available. Should this product require service (or replacement at our option), please pack the item carefully and return it prepaid, along with receipt showing date of purchase and a note explaining reason for return to:

There are no expressed warranties except as listed above. This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
For additional product information, or warranty information outside the USA, please contact us through www.taylorusa.com.
© 2022 Taylor, a division of Lifetime Brands, Inc. All rights reserved.
Made to our exact specifications in China.

CONTACT

  • ADDRESS: Taylor, a division of Lifetime Brands, Inc. 2220 Entrada del Sol, Suite A Las Cruces, New Mexico 88001
  • Customer Service Phone: 1-800-225-4834
  • Customer Service Fax: 1-575-526-4347
  • www.taylorusa.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TAYLOR User Manuals

Related Manuals