Mainline SK7 Wireless Access Control User Manual

October 30, 2023
Mainline

Mainline SK7 Wireless Access Control User Manual

INTRODUCTION

The device is a single door wireless access control, consists of a wireless & waterproof keypad, a mini controller and a wireless exit button. 433MHz Rlling Code of encryption algorithm and the split design guarantees higher-secure.
The keypad can store 1100 PIN / card users, including 1000 common users and 100 visitor users. PIN length can be 4-8 digits. The controller is with internal & external alarm, door contact, exit button (wired) and door bell.
Because of ultra low power consumption, the keypad and exit button can work as long as one year (based on 20 times/day), with just 3 units of AAA batteries and 1 unit L-battery. It will remind people to replace batteries intelligently I low battery.

Two Versions available

  • ABS:  Waterproof Plastic Keypad + Controller+ Exit Button
  • Metal:  Waterproof Metal Touch Keypad +Controller+ Exit Button

Features

  • Waterproof, conforms to IP65
  • 1100 PIN/ card users (1000 common users + 100 visitor users)
  • 125MHz EM Card/13.56MHz Mifare Card (Optional)
  • PIN length: 4-8 digits
  • Backlit Keypad
  • Communication frequency: 433MHz
  • Communication distance: s30m
  • Door contact, alarm and door bell output
  • Pulse mode, toggle mode
  • Tri-color LED status display
  • Ultra low power consumption (wireless keypads10uA)
  • Remote Control optional

Specifications

Carton Inventory

INSTALLATION

Method 1: Stick by 3M stickers
The device packed with 3M double-side Stickers, can easily stick the Wireless Keypad and Wireless Button on Metal Door, Glass Door, Wooden Door, or Smooth Wall.
Method 2:   Install by screws.

Wiring (Mini Controller)

Sound and Light Indication

Connection Diagram

Access Control Power Supply:

Common Power Supply:

Attention:  Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4004 is included in the packing)

Reset to Factory Default for Keypad

For Metal Keypad:

Method 1:
First Power Off, then Power On for 4s, then press # and hold it (Note: Must press # after the power is on between 4 second and 10 second), there will be one beep after 5 seconds, release the # button, means reset to factory default successfully.

Method 2:
Power on, read ‘Reset Card’ once, there will be one long beep, means reset to factory default succesfully (Reset Card is not included in the package, users can add the Reset Card when needed, refer to Page 12)

For ABS Keypad:
Power off, press * and hold it, then power on, there will be one beep after 5 seconds, then release the button, means reset to factory default succesfully

Remarks:

  1. Reset to factory default, the user’s information is still retained.
  2. Keypad needs to pair with controller after reset

PROGRAMMING

Enter and Exit Program Mode

Set Master Code

Add / Delete Master Cards

(Master Cards are included and added already. When new Master Cards added, the previous one will be replaced)

Master Cards Using

Add User PIN(s) User ID:  0-999; PIN length: 4-8 digits

Add User Card(s)
User ID: 0-999; Card type: 125 KHz EM Card/13.56MHz Mifare Card

Add Visitor Users
There are 100 groups Visitor PIN/ card available, the users can be specified up to 9 times of usage, after a certain number of times, i.e.
5times, the PIN/card become invalid automatically.
User ID: 00-099 (the leading zero of the User ID means Visitor Users)

Change PIN Users

Delete Users

Set Access Mode

Set Relay Configuration
The relay configuration sets the behavior of the output relay on activation.

Set Door Bell  (for Mini Controller)

Remarks:  press Door Bell on keypad, there will be 2 times ‘dingdong’ from mini controller

Set Safety Mode
If set Strike-out ON, the keypad will deny access for 10 minutes after 10 failed
PIN/card attempts in 10 minutes (Factory is OFF)

Set Anti-tamper Alarm

Remarks.  When anti-tamper alarm is triggered, keypad alarm, mini controller alarm and external alarm will trigger an alarm. User can close the cover/ Master Code # /Valid Card or PIN # to release the alarm, or until the alarm time (1 minute) is finished.

Set Door Open Detection
Door Open Too Long (DOTL) Detection
When use with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door. The beep can be stopped by closing the door, valid users or press exit button, or else, it will continue to beep the same time with the alarm time set.

Door Forced Open Detection
When use with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened by force, the inside buzzer and external alarm (if there is) will both operate, they can be stopped by valid users or press exit button, or else, it will continue to sound the same time with the alarm time set.

Set Buzzer


Set Reset Card (Factory default is not including Reset Card)

Remarks:

  1. Reset cards cannot access the door; it can only reset the Wireless Keypad.
  2. Reset card can be replaced, any new added card will replace the previous one.
  3. Pairing is necessary after reset the device.

OTHERS

Users Operation

Pair Wireless Keypad/ Exit Button and Mini Controller

  1. They are already paired when out of factory, if no problem, the users do not need to do this operation in using.
  2. One Mini Controller can be connected by 5 pieces of VWireless Keypad and Exit Button maximum.
  • To pair the wireless keypad and the controller:
    Mini Controller:  Remove the back cover, and press the button “Pair
    Wireless Keypad:  ” Master Code # 8 0#, press * on the keypad to exit.
    If pair successfully, there will be one beep from both the controller and the keypad; if not, there ill be three short beeps, then please repeat the setting.

  • To pair the wireless button and the controller:
    Mini Controller:  Remove the back cover, and press the button “Pair
    Wireless Button:  Remove the back cover, and press the button “Pair, after hearing one beep, press “Pair’ again to exit paring mode f pair successfully, there will be one beep from both the controller and the exit button; if not, there will be three short beeps, then please repeat the setting.

  • To pair the wireless keypad with multiple mini controller
    Wireless Keypad:  Master Code # 80#
    Mini Controller:  Remove the back cover, and press the button “Pair (Same settings for multiple controllers)
    If pair successfully, there will be one beep from both the controller and the keypad, press on the keypad to exit paining mode; it not, there will be three
    short beeps, then please repeat the setting. Users need to finish the pairing within 30s for multiple controllers, or else, the keypad will exit pairing mode automatically.

  • To pair the wireless button with multiple mini controller:
    Wireless Button:  Remove the back cover, and press the button “Pair
    Mini Controller:  Remove the back cover, and press the button “Pair’ (Same settings for multiple controllers)
    f pair successfully, there will be one beep from both the controller and the button, press the button “Pair’ on the button to exit pairing mode; if not, there will be three short beeps, then please repeat the setting. Users need to finish the pairing within 30s for multiple controllers, or else, the keypad mill exit painng mode automatically.

Read More About This Manual & Download PDF:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Mainline User Manuals

Related Manuals