URFOG FPU250PPP Fast 250 Pump Pro Plus Purifog User Manual
- June 4, 2024
- URFOG
Table of Contents
URFOG FPU250PPP Fast 250 Pump Pro Plus Purifog
DEFECTS POSSIBLE SOLUTION
DEFECT FOUND | POSSIBLE CAUSE | POSSIBLE SOLUTION |
---|
BLUE LED is flashing
The buzzer emits a continuous sound
BLUE and RED LEDS
are flashing alternately
|
Overvoltage power line (110/240 V)
|
Try to reset. In case of unsuccessful restore
the PCB can be damaged, contact the assistance service.
Overtemperature of the PCB
|
Check there is a sufficient ventilation around the machine.
Disturbance / interference or potential differences between devices
| In the case of strong interference (lightning) can occur a thermocouple
reading error, make a reset. In case of unsuccessful restore can be occurred a
potential difference or a fault.
In large size plants or with more than on fogging system connected with the
same central, in rare situations, it may occur that there are potential
differences between the equipments and it could be necessary to uncouple them.
Error in the thermal loop
|
Possible fault of: thermocouple, resistance or fuse cable. Don’t try to repair.
Contact the assistance service center.
Impossible to arm the machine BLUE LED doesn’t switch on
|
Wiring error
| Check on the terminal with a tester that when the alarm system is tuned on there is a minimum voltage of 11 V between – GND (5) + ARM (3).
When you press the reset button you don’t hear
the sound of the buzzer,
the frontal LED are flashing but the RED LED does not reset
|
The Jumper P3
is in the “SET” position
|
Warning in this case shooting time is reset to zero
Setting the shooting time, the buzzer does not sound and the LEDs do not flash
|
The jumper P3 stands in the “RESET” position
|
See the setting mode of the shooting
FAST PUMP PRO PLUS
FAST 250 PUMP PRO PLUS FAST 500 PUMP PRO PLUS FAST 1500 PUMP PRO PLUS FAST
4000 PUMP PRO PLUS
User manual FAST PUMP PRO PLUS AU/NZL rev. 10/01/2022
FRONT LEDS MEANING
- The purpose of this manual is to provide simple indications to report to the person in charge of the maintenance or assistance of the device for the diagnosis of any malfunctions.
- The unit should not be opened (not even for the replacement of liquid bags) by unqualified personnel.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance
- BLUE LED
- When on : the machine is armed and, if hot, it’s ready to shoot.
- When flashing : something is wrong (see “DEFECTS AND POSSIBLE SOLUTIONS“)
- RED LED
- When on : the bag is empty or it is in reserve.
- When flashing: something is wrong (see “DEFECTS AND POSSIBLE SOLUTIONS“)
- GREEN LED
- When on : the machine is hot and ready for the fog emission.
- When flashing : the heating process is in progress. In this step the machine is heating but is not ready to shoot.
Warning
IF THE BLUE LED IS FLASHING, TOGETHER WITH A CONTINUOUS SOUND FROM THE BUZZER, A PROBLEM IS DETECTED. SEE “DEFECTS AND POSSIBLE SOLUTIONS”
The symbol of empty bag, has the meaning of “RESERVE” It means that, since the last bag reset the machine has shot at least 100” (PUMP 250) or 60” ( PUMP 500).
DEFECTS POSSIBLE SOLUTION
DEFECT FOUND | POSSIBLE CAUSE | POSSIBLE SOLUTION |
---|---|---|
When you arm the machine you hear an internal buzz, like a motor | The |
compressor is cheching that there are no obstructions in the circuit of fog emission| When the machine is armed, for 15 minutes the compressor will monitor the nozzle. After this time it will deactivate automatically: if the fogging system is disarmed, the compressor will go on with it reaches 15 minutes.
If the machine is disarmed and then armed again, the count will start again from zero.
When you arm the fogging system, a little fog flow goes out from the nozzle even if the machine has never shot before| During testing phase in the factory, we also test the quality of fog in all produced systems, a little quantity of the fog liquid remains in the ducts| This emission occurs just at first activation, it will decrease visibly with any activation, until disappea- ring completely.
After an eventual disassembly and reinstallation or after the transport of the machine, with the first activations a little flow of fog can occur again.
The 3 frontal LED are flashing and the buzzer emits 1 beep for minute| The tension on +12 V input is too low or too high|
Check the external power supply or the alarm unit
The buzzer emits 2 beep for minute| Low battery but possible shot|
Verify/replace battery
The buzzer emits 3 beep for minute| Low battery but possible shot|
Verify/replace battery
The buzzer emits 10 continuous beep for minute
| Battery not present| Insert battery
Connector not inserted correctly|
Remove and reinsert the connector
Verify that jumper W5 is inserted|
Insert jumper W5
The machine is armed (BLUE LED ON)
but doesn’t shoot
|
The front RED LED is on
|
Bag reset has not been made
Bag is in reserve or empty-Change the bag
The front GREEN LED flashes
| The heat exchanger has not yet reached the minimum temperature of shooting, wait for the led to stop flashing standard heating time: 60 min.
Wiring error
| Verify that the alarm, once activated has tension on connectors of at least 12 V between GND(5) + SHOOTS(4)