NATIONAL INSTRUMENTS NI-9221 8 Channel C Series Voltage Input Module
Product Information: NI-9927
The NI-9927 is a data acquisition module that is used to measure voltage signals. It comes in three variations: NI 9221 with screw terminal, NI 9221 with spring terminal, and NI 9221 with DSUB.
Getting Started Guide for NI 9221
The Getting Started Guide explains how to connect to the NI 9221. Before
starting, ensure that you have completed the software and hardware
installation procedures in your chassis documentation. The guidelines provided
in the document are specific to the NI 9221. Refer to the documentation for
each component in the system to determine the safety and EMC ratings for the
entire system.
Safety Guidelines
Operate the NI 9221 only as described in the Getting Started Guide. Do not
operate the NI 9221 in a manner not specified in the guide as product misuse
can result in a hazard. If the product is damaged, return it to NI for repair.
Hazardous Voltage
The hazardous voltage icon denotes a warning advising you to take precautions
to avoid electrical shock.
NI 9221 with Screw Terminal and NI 9221 with Spring Terminal Safety
Voltages
Connect only voltages that are within the following limits:
- Channel-to-COM: Continuous 250 Vrms, Measurement Category II
- Channel-to-channel: Withstand 2,300 Vrms, verified by a 5 s dielectric withstand test
- Channel-to-earth ground: Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system.
Do not connect the NI 9221 with screw terminal or NI 9221 with spring terminal to signals or use for measurements within Measurement Categories III or IV.
NI 9221 with DSUB Safety Voltages
Connect only voltages that are within the following limits:
- Channel-to-COM: Continuous 60 VDC, Measurement Category I
- Channel-to-channel: Withstand 1,000 Vrms, verified by a 5 s dielectric withstand test
- Channel-to-earth: Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage.
Do not connect the NI 9221 with DSUB to signals or use for measurements within Measurement Categories III or IV. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV.
Safety Guidelines for Hazardous Voltages
You can connect hazardous voltages only to the NI 9221 with screw terminal
and the NI 9221 with spring terminal. Do not connect hazardous voltages to the
NI 9221 with DSUB.
Product Usage Instructions
Follow the instructions provided in the Getting Started Guide to connect to the NI 9221. Ensure that you connect only voltages that are within the specified limits. Do not connect hazardous voltages to the NI 9221 with DSUB. If the product is damaged, return it to NI for repair.
Bridging the gap between the manufacturer and your legacy test system.
COMPREHENSIVE SERVICES
We offer competitive repair and calibration services, as well as easily
accessible documentation and free downloadable resources.
RESET SELL YOUR SURPLUS
We buy new, used, decommissioned, and surplus parts from every NI series. We
work out the best solution to suit your individual needs.
- Sell For Cash
- Get Credit
- Receive a Trade-In Deal
OBSOLETE NI HARDWARE IN STOCK & READY TO SHIP
We stock New, New Surplus, Refurbished, and Reconditioned NI Hardware.
1-800-915-6216
www.apexwaves.com
sales@apexwaves.com
All trademarks, brands, and brand names are the property of their respective owners.
Request a Quote CLICK HERE USB-6216
This document explains how to connect to the NI 9221. In this document, the NI 9221 with screw terminal, NI 9221 with spring terminal, and NI 9221 with DSUB are referred to inclusively as the NI 9221.
- Note Before you begin, complete the software and hardware installation procedures in your chassis documentation.
- Note The guidelines in this document are specific to the NI 9221. The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system.
Safety Guidelines
Operate the NI 9221 only as described in this document.
Caution Do not operate the NI 9221 in a manner not specified in this document. Product misuse can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to NI for repair.
Hazardous Voltage This icon denotes a warning advising you to take precautions to avoid electrical shock.
NI 9221 with Screw Terminal and NI 9221 with Spring Terminal Safety Voltages
Connect only voltages that are within the following limits.
- Channel-to-COM ±60 VDC maximum
- Channel-to-channel None
- Channel-to-earth ground
- Continuous 250 Vrms, Measurement
- Category II
- Withstand 2,300 Vrms, verified by a 5 s dielectric withstand test
Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system. This category refers to local-level electrical distribution, such as that provided by a standard wall outlet, for example, 115 V for U.S. or 230 V for Europe.
Caution Do not connect the NI 9221 with screw terminal or NI 9221 with spring terminal to signals or use for measurements within Measurement Categories III or IV.
NI 9221 with DSUB Safety Voltages
Connect only voltages that are within the following limits.
- Channel-to-COM ±60 VDC maximum
- Channel-to-channel None
- Channel-to-earth
- Continuous 60 VDC, Measurement
- Category I
- Withstand 1,000 Vrms, verified by a 5 s dielectric withstand test
Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.
- Caution Do not connect the NI 9221 with DSUB to signals or use for measurements within Measurement Categories III or IV.
- Note Measurement Categories CAT I and CAT O are equivalent. These test and measurement circuits are not intended for direct connection to the MAINS building installations of Measurement Categories CAT II, CAT III, or CAT IV.
Safety Guidelines for Hazardous Voltages
You can connect hazardous voltages only to the NI 9221 with screw terminal and
the NI 9221 with spring terminal. Do not connect hazardous voltages to the NI
9221 with DSUB.
If hazardous voltages are connected to the device, take the following
precautions. A hazardous voltage is a voltage greater than 42.4 Vpk voltage or
60 VDC to earth ground.
- Ca ution Ensure that hazardous voltage wiring is performed only by qualified personnel adhering to local electrical standards.
- Caution Do not mix hazardous voltage circuits and human-accessible circuits on the same module.
- Caution Ensure that devices and circuits connected to the module are properly insulated from human contact.
- Caution When module terminals are hazardous voltage LIVE (>42.4 Vpk/60 VDC), you must ensure that devices and circuits connected to the module are properly insulated from human contact. You must use the NI 9927 connector backshell kit with the NI 9221 with screw terminal and the NI 9981 connector backshell kit with the NI 9221 with spring terminal to ensure that the terminals are not accessible.
Safety Guidelines for Hazardous Locations
The NI 9221 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4
hazardous locations; Class I, Zone 2, AEx nA IIC T4 and Ex nA IIC T4 hazardous
locations; and nonhazardous locations only. Follow these guidelines if you are
installing the NI 9221 in a potentially explosive environment. Not following
these guidelines may result in serious injury or death.
- Caution Do not disconnect I/O-side wires or connectors unless power has been switched off or the area is known to be nonhazardous.
- Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous.
- Caution Substitution of components may impair suitability for Class I, Division 2.
- Caution For Division 2 and Zone 2 applications, install the system in an enclosure rated to at least IP54 as defined by IEC/EN 60079-15.
- Caution For Zone 2 applications, install a protection device between the input signal and the NI 9221 input terminal. The device must prevent the channel-to-COM voltage from exceeding 85 V if there is a transient overvoltage condition.
Special Conditions for Hazardous Locations Use in Europe and
Internationally
The NI 9221 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO
Certificate No. 03 ATEX 0324020X and is IECEx UL 14.0089X certified. Each NI
9221 is marked II 3G and is suitable for use in Zone 2 hazardous locations, in
ambient temperatures of -40 °C ≤ Ta ≤ 70 °C. If you are using the NI 9221 in
Gas Group IIC hazardous locations, you must use the device in an NI chassis
that has been evaluated as Ex nC IIC T4, Ex IIC T4, Ex nA IIC T4, or Ex nL IIC
T4 equipment.
- Caution You must make sure that transient disturbances do not exceed 140% of the rated voltage.
- Caution The system shall only be used in an area of not more than Pollution Degree 2, as defined in IEC 60664-1.
- Caution The system shall be mounted in an ATEX/IECEx-certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC/EN 60079-15.
- Caution The enclosure must have a door or cover accessible only by the use of a tool.
Electromagnetic Compatibility Guidelines
This product was tested and complies with the regulatory requirements and
limits for electromagnetic compatibility (EMC) stated in the product
specifications. These requirements and limits provide reasonable protection
against harmful interference when the product is operated in the intended
operational electromagnetic environment.
This product is intended for use in industrial locations. However, harmful
interference may occur in some installations, when the product is connected to
a peripheral device or test object, or if the product is used in residential
or commercial areas. To minimize interference with radio and television
reception and prevent unacceptable performance degradation, install and use
this product in strict accordance with the instructions in the product
documentation. Furthermore, any changes or modifications to the product not
expressly approved by National Instruments could void your authority to
operate it under your local regulatory rules.
Special Conditions for Marine Applications
Some products are Lloyd’s Register (LR) Type Approved for marine (shipboard)
applications. To verify Lloyd’s Register certification for a product, visit
ni.com/certification and search for the LR
certificate, or look for the Lloyd’s Register mark on the product.
Caution In order to meet the EMC requirements for marine applications, install
the product in a shielded enclosure with shielded and/or filtered power and
input/output ports. In addition, take precautions when designing, selecting,
and installing measurement probes and cables to ensure that the desired EMC
performance is attained.
Preparing the Environment
Ensure that the environment in which you are using the NI 9221 meets the following specifications.
- Operating temperature (IEC 60068-2-1, IEC 60068-2-2) -40 °C to 70 °C
- Operating humidity (IEC 60068-2-78) 10% RH to 90% RH, noncondensing
- Pollution Degree 2
- Maximum altitude 2,000 m
Indoor use only.
Note Refer to the device datasheet on ni.com/manuals for complete specifications.
NI 9221 Pinout
Table 1. Signal Descriptions
Signal | Description |
---|---|
AI | Analog input signal connection |
COM | Common reference connection |
NC | No connection |
Single-Ended Connections
NI 9221 Connection Guidelines
- Make sure that devices you connect to the NI 9221 are compatible with the module specifications.
- You must use 2-wire ferrules to create a secure connection when connecting more than one wire to a single terminal on the NI 9221 with screw terminal or NI 9221 with spring terminal.
High-Vibration Application Connections
If your application is subject to high vibration, NI recommends that you
follow these guidelines to protect connections to the NI 9221 with screw
terminal or the NI 9221 with spring terminal:
- Use ferrules to terminate wires to the detachable connector.
- Use the NI 9927 backshell kit with the NI 9221 with screw terminal or the NI 9981 backshell kit with the NI 9221 with spring terminal.
Overvoltage Protection
The NI 9221 provides overvoltage protection for each channel.
Note Refer to the device datasheet on ni.com/manuals for more information about overvoltage protection.
Where to Go Next
C Series Documentation & Resources
ni.com/info cseriesdoc
Services
ni.com/services
Located at ni.com/manuals
Installs with the software
Worldwide Support and Services
The NI website is your complete resource for technical support. At
ni.com/support, you have access to everything from
troubleshooting and application development self-help resources to email and
phone assistance from NI Application Engineers.
Visit ni.com/services for NI Factory Installation
Services, repairs, extended warranty, and other services.
Visit ni.com/register to register your NI product.
Product registration facilitates technical support and ensures that you
receive important information updates from NI.
A Declaration of Conformity (DoC) is our claim of compliance with the Council
of the European Communities using the manufacturer’s declaration of
conformity. This system affords the user protection for electromagnetic
compatibility (EMC) and product safety. You can obtain the DoC for your
product by visiting ni.com/certification. If
your product supports calibration, you can obtain the calibration certificate
for your product at ni.com/calibration. NI
corporate headquarters is located at
11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices
located around the world. For telephone support in the United States, create
your service request at ni.com/support or dial 1 866
ASK MYNI (275 6964). For telephone support outside the United States, visit
the Worldwide Offices section of ni.com/niglobal to
access the branch office websites, which provide up-to-date contact
information, support phone numbers, email addresses, and current events.
Refer to the NI Trademarks and Logo Guidelines at
ni.com/trademarks for information on NI
trademarks. Other product and company names mentioned herein are trademarks or
trade names of their respective companies. For patents covering NI
products/technology, refer to the appropriate location: Help»Patents in your
software, the patents.txt file on your media, or the National Instruments
Patent Notice at ni.com/patents. You can find
information about end-user license agreements (EULAs) and third-party legal
notices in the readme file for your NI product.
Refer to the Export Compliance Information at ni.com/legal/export-
compliance for the NI global trade
compliance policy and how to obtain relevant HTS codes, ECCNs, and other
import/ export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE
ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY
ERRORS. U.S. Government Customers: The data contained in this manual was
developed at private expense and is subject to the applicable limited rights
and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014,
and DFAR 252.227-7015.
© 2016 National Instruments. All rights reserved.
377101A-01 Nov16
References
- Engineer Ambitiously - NI
- Calibration Services - NI
- Product Certifications - NI
- Using Info Codes - NI
- Trade Compliance - NI
- Product Documentation - NI
- Contact Us - NI
- National Instruments Patents - NI
- Log In - National Instruments
- NI Services - NI
- Support - NI
- NI Trademarks and Logo Guidelines - NI
- Calibration Services - NI
- Product Certifications - NI
- Product Documentation - NI
- Contact Us - NI
- Log In - National Instruments
- NI Services - NI
- Support - NI
- NI-9927 National Instruments Backshell Connector Kit | Apex Waves
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>