JONARD TOOLS SA-90 Series Arm Mounted Fume Absorber Conversion Kit Instruction Manual

October 30, 2023
JONARD TOOLS

JONARD TOOLS SA-90 Series Arm Mounted Fume Absorber Conversion Kit

Congratulations on purchasing the SA-90/SAK-90 Fume Absorber System from OK Industries. The unit has been tested and inspected prior to shipment. Kindly contact us directly for any comments or suggestions.

Product Information

  • The SA-90/SAK-90 Fume Absorber System is designed to absorb and filter fumes that may be hazardous to health.
  • The SA-90 Series is a complete system that includes a manual contained in the SA-9 Fume Absorber box.
  • The SAK-90 Conversion Kit is designed to convert the SA-9 Fume Absorber into an arm-mounted fume absorber.
  • The kit includes thumb screws, cable guides, an arm mounting bracket, and instructions.

Product Usage Instructions

  1. SA-90 SERIES: Refer to the SA-9 manual contained in the SA-9 Fume Absorber box. OMIT STEP #1.
  2. SAK-90: Remove the exhaust air deflector from the rear of your SA-9 series FUME ABSORBER.
  3. Using the thumb-screws provided with the SA-9, mount the SA-9 to the U shaped bracket. IMPORTANT: YOU MUST ROUTE THE POWER CORD BELOW THE U SHAPED BRACKET.
  4. Use the two cable guides provided to hide the power cord along the outside sections of the arm assembly. Simply push the guides over one of the arms on the SAK-90. Be sure to run power cord before pushing guide on to the arm.
  5. Clamp the arm mounting bracket in a suitable location on the workbench, insert the arm assembly, and connect the main power cord.

For any further assistance, kindly contact our customer support team.

ASSEMBLY INSTRUCTIONS

Congratulations on your purchase of our SA-90/SAK-90 Fume Absorber System. This unit has been tested and inspected by OK Industries prior to shipment. We appreciate your comments and suggestions. Please feel free to contact us directly:

PLEASE FOLLOW THESE INSTRUCTIONS

  1. SA-90 SERIES – Please refer to the SA-9 manual contained in the SA-9 FUME ABSORBER box. OMIT STEP #1.
  2. SAK-90 Remove the exhaust air deflector from the rear of your SA-9 series FUME ABSORBER.
  3. Using the thumb-screws provided with the SA-9 mount the SA-9 to the “U” shaped bracket.
    • IMPORTANT: YOU MUST ROUTE THE POWER CORD BELOW THE “U” SHAPED BRACKET
  4. Use the two cable guides provided to hide the power cord along the outside sections of the arm assembly. Simply push the guides over one of the arms on the SAK-90. Be sure to run power cord before pushing guide on to the arm.
  5. Clamp the arm mounting bracket in a suitable location on the workbench, insert the arm assembly and connect the main power cord.

Contact

  • 134 Marbledale Road, Tuckahoe, NY 10707
  • Tel: 914.793.0700
  • Fax: 914.793.4527
  • jonard.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

JONARD TOOLS User Manuals

Related Manuals