TECHNICAL SPECIFICATIONS
KEY FEATURES
INSTRUCTIONS
Setting Up Your OFl-100
Before powering on your OFl-100, make sure to insert the included AA
batteries. To do so, first open the battery compartment by peeling the bottom
of the protective sleeve off. Next, unscrew the lowest screw using the
included flathead screwdriver, and remove the battery cover. Finally, insert
the batteries in the correct polarity positions, and replace the battery cover
and protective sleeve.
Selecting the Adapter
- Select the appropriate adapter head based on the size of fiber cable being tested. There are 3 mm, 2 mm, and 950 nm options for jacketed fiber, and a 250 nm adapter for testing bare fiber
- To access the adapter, pull back the top part of the OFl-1 OO’s rubber sleeve to reveal the plastic cover underneath
- Next, slide the plastic cover upwards to reveal the adapter inside
- You can zero out the power meter by holding the dB/dBm key. You can also change the display results from dBm to dB by pressing the dB/dBm key.
- Then, remove the adapter and reinstall it as needed.
- a. Note that the text on the adapter indicates which sizes of fiber can be used.
- b. One side handles 250 & 900 um fiber, while the other side handles 2 & 3 mm fiber.
- When ready to test the fiber, place the fiber into the adapter and pull the trigger on the back of the unit to clamp down onto the fiber.
- The OFl-100 will automatically display the signal transmission direction, estimated signal power, and modulation frequency
- a. Note that if there is a frequency in the test link, there will be a corresponding frequency display and beeping prompt at the bottom of the screen.
of force, at this time the instrument screen interface displays the test data. If there is a modulation frequency in the test link, there will be a corresponding frequency display and beeping
How to Use the Optical Power Meter (OPM) Module
- Press the meter “( ) “power button to power on. At this time, the meter will display the test interface of the power meter module.
- Slide down the stopper at the on the right side of the meter to reveal the VFL and OPM ports.
- Insert the fiber you want to test into the OPM port, with the other end connected to a light source
- You can also change the display results from dBm to dB using the dB/dBm key.
How to Use the Visual Fault Locator (VFL) Module
- Press the meter” ( )”power button to power on. At this time, the meter will display the test interface of the power meter module.
- Slide down the stopper at the on the right side of the meter to reveal the VFL and OPM ports.
- Insert the fiber you want to evaluate into the VFL port
- Press the VFL key to initiate the VFL.
- a. Note that a red —. symbol will appear in the top-right corner of the screen, indicating the VFL’s laser is on.
- Press the VFL key again to change the frequency from CW to 1 Hz.
- a. Note that the red 181 symbol will start flashing
- To turn off the VFL module, simply press the VFL key once more.
MAINTENANCE
- The OFl-100 may not work while under heavy vibrations
- Use a dust-free paper or cleaning cloth and isopropyl alcohol, or fiber cleaning fluid, to clean the end surface.
- When the equipment is not in use, please store it in the pouch to protect it from dust.
- Insert and remove any optical connectors carefully to prevent damage.
WARRANTY AND SERVICE
Jonard Tools offers our unique Made For Life®, Guaranteed For Life warranty on almost every product we make! Please see the chart below for details.
Jonard Tools products are warrantied to be free from defects in materials and workmanship for the normal life of the product. Different products have different warranty periods, listed above in our warranty policy. Jonard Tools warranty only covers the repair, replacement, or refund of a Jonard Tools product, it does not cover and nor shall Jonard Tools be liable for any special, indirect, incidental, or consequential damages or loss. At Jonard Tools discretion we will repair, replace, or refund the purchase price of any product found to be defective. The warranty does not apply to products that have been deemed by Jonard Tools to have been abused, misused, or altered in any way whether intentional or by accident.