enelion Wallbox AC Charger Compact and Efficient Home Charging Instruction Manual Wallbox – Assembly Manual
- October 30, 2023
- enelion
Table of Contents
- Wallbox AC Charger Compact and Efficient Home Charging
- Wallbox – Assembly Manual
- General Information
- Important Information
- General Provisions
- Safety Instructions
- Opening and Closing Enelion Wallbox
- Recommended Power Connection
- Recommended Communication Network
- Location Selection Criteria
- Preparing the Installation
- Selection of Bolts and Anchors
- Cable Routes
- Mounting the Device
- Power Connection
- Enelion Chain
- Internet Connections via Ethernet Interface in LAN Network
- Cleaning
- Enelion Wallbox
Wallbox AC Charger Compact and Efficient Home Charging
Wallbox – Assembly Manual
General Information
The Enelion Wallbox is a device used for electric vehicle
charging. The device is designed to be installed and serviced by
qualified and authorized persons only. Any tampering with the
mechanical, electrical, and electronic components and the device
software is strictly forbidden and may result in the nullification
of the warranty.
Important Information
General Provisions
Installation and servicing of the device must be performed by
qualified and authorized persons, and repairs may only be carried
out by the manufacturer or entities authorized by the manufacturer.
The exceptions include operations described herein and those agreed
in writing with the manufacturer.
Safety Instructions
Ensure that the module packages contain all the elements before
initiating any activities related to the installation or the
activation of the charger. See the contents of the manual before
starting any installation activities.
General Information
Opening and Closing Enelion Wallbox
The Enelion Wallbox can be opened by unlocking the device using
a key or an RFID card. The device should be closed after use to
protect it from environmental factors.
Design Indications of the Installation
Recommended Power Connection
The Enelion Wallbox requires a power connection of 230V AC, with
a maximum power output of 22 kW. The device should be connected to
a circuit breaker that is capable of handling the maximum power
output of the device.
Recommended Communication Network
The Enelion Wallbox supports communication via Ethernet
interface in LAN network. The device should be connected to a LAN
network for remote management and monitoring.
Location Selection Criteria
The Enelion Wallbox should be installed in a dry, indoor
location, protected from direct sunlight and other environmental
factors. The device should be installed in a location that is
easily accessible for user convenience.
Assembly
Preparing the Installation
Before starting the installation, ensure that all the necessary
components are present in the module packages. The installation
should be performed by qualified and authorized persons only.
Selection of Bolts and Anchors
The Enelion Wallbox should be mounted using bolts and anchors
that are capable of supporting the weight of the device. The
recommended bolts and anchors should be used to ensure the safety
and stability of the device.
Cable Routes
The cables should be routed in a way that ensures the safety and
stability of the device. The cables should be protected from
environmental factors and should not interfere with other devices
or structures.
Mounting the Device
The Enelion Wallbox should be mounted on a flat, stable surface
using the recommended bolts and anchors. The device should be
mounted in a way that ensures the safety and stability of the
device.
Connection
Power Connection
The Enelion Wallbox can be connected to a power source using a
standard power connection or a power connection in version with MID
meter. The device should be connected to a circuit breaker that is
capable of handling the maximum power output of the device.
Enelion Chain
The Enelion Chain is a feature that allows for remote management
and monitoring of the device. The device should be connected to a
LAN network for this feature to work.
Internet Connections via Ethernet Interface in LAN Network
The Enelion Wallbox supports communication via Ethernet
interface in LAN network. The device should be connected to a LAN
network for remote management and monitoring.
Maintenance
Cleaning
The Enelion Wallbox should be cleaned regularly to ensure the
safety and stability of the device. The device should be cleaned
using a dry cloth or a cloth dampened with water.
Technical Data
Enelion Wallbox
The Enelion Wallbox requires a power connection of 230V AC, with
a maximum power output of 22 kW. The device supports communication
via Ethernet interface in LAN network.
Wallbox
Assembly manual
Enelion Sp. z o.o.
info@enelion.com
Copyright, Enelion Sp. z o. o.
The manual may change as the product develops. The information provided may
not be correct. All rights reserved.
Revision: V 3.7 Number of pages: 23 Released: July 19, 2022
Wallbox – Assembly manual
7 – 2022
Contents
1 Important information
4
1.1 General Provisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 General information
5
2.1 Opening and closing Enelion Wallbox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 Design indications of the installation
8
3.1 Recommended power connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.2 Recommended communication network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.3 Location selection criteria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4 Assembly
10
4.1 Preparing the installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.2 Selection of bolts and anchors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.3 Cable routes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.4 Mounting the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5 Connection
13
5.1 Power connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.1.1 Standard power connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.1.2 Power connection in version with MID meter . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.1.3 RCM B Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.2 Enelion Chain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.3 Internet connections via Ethernet interface in LAN network . . . . . . . . . . . . . . . . . . . . . . 18
6 Maintenance
19
6.1 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7 Technical data
20
7.1 Enelion Wallbox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
2
Contents
Wallbox – Assembly manual
7 – 2022
Before the installation, make sure that the module packages contain all the
elements. Current version of the operation manual can be accessed at
http://enelion.com/en/help/.
See the contents of the manual before initiating any activities related to the
installation or the activation of the charger.
3
Contents
Wallbox – Assembly manual
7 – 2022
1. Important information
1.1. General Provisions
Installation and servicing of the device must be performed by qualified and
authorized persons, and repairs may only be carried out by the manufacturer or
entities authorized by the manufacturer.
Tampering with the mechanical, electrical and electronic components and the
device software is forbidden and shall result in the nullification of the
warranty. The exceptions include operations described herein and those agreed
in writing with the manufacturer.
It is forbidden to use any extensions of the charging cable.
The manufacturer is not responsible for loss of health or life by any persons
resulting from failure to comply with the above-mentioned recommendations.
The data plate on the device is an integral part of the device and its removal
or damage shall result in the nullification of the warranty.
1.2. Safety instructions
The manufacturer is not responsible for damage to property resulting from the
forbidden interference in the product.
The electrical installation to be used by the device during its operation must
meet the conditions described in the installation manual. The manufacturer is
not responsible for incorrect assembly and/or protection of the electrical
installation to which the device is connected.
Outdoor installation should not be carried out during precipitation or strong
wind, if there is a risk that water or dirt may get into the device.
All operations described in this manual should be performed only having made
sure that there is no voltage in the power cable.
The manufacturer is not responsible for the malfunction of the electrical installation to which the device is connected.
The electrical installation to be used by the device during its operation must comply with the legal standards in force in the place of assembly and the operation of the device. The manufacturer is not liable for any damage caused by an electrical installation that does not meet legal standards.
The device does not have a built-in switch. The device activates when the supply voltage is applied. The power supply cut off function must be provided by the appropriate electrical installation devices described in the assembly manual. Except in emergencies, the device must not be turned off during the charging process.
It is forbidden to supply the power to the device when the device casing remains open.
The use of a mechanically damaged charger or a charger that indicates a critical error is forbidden.
It is forbidden to place in the charger socket any objects not intended for this purpose. A working power cable with a cross-section appropriate for the power supplied to the device and appropriate for the type of electric vehicle, terminated with a functional plug type 2 in accordance with EC 62196-2 is the only object that may be plugged in the charger socket.
4
Important information
Wallbox – Assembly manual
7 – 2022
2. General information
Wallbox is a charging station intended for electric road passenger vehicles. It is made of an aluminum casing, closed at its sides with reinforced polymer material. It includes a charging process control module, a front panel with an RFID reader, an OLED screen and LED signaling, and a TYPE 2 socket. Additional accessories can be installed. The range of functions of the device can be extended by adding such accessories as Enelion Bridge, Enelion MID or Enelion RCM B protection. Some parameters and functions can be changed by reprogramming the device with the use of the attached RFID card. Enelion Wallbox is available in two colors: black and silver.
INFO For more information, see the “User Guide”. It contains detailed
information about the functionality and use of the device.
2.1. Opening and closing Enelion Wallbox
INFO
The 3 mm Allen key included with the charger is needed to open (or close)
the Enelion Wallbox. No other tool is necessary for this operation.
INFO
Closing of the device is performed by repeating the steps in the reverse
order.
Fig. 1: Enelion Wallbox in black.
All Enelion charging stations are compatible with the original Enelion Chain
communication protocol, which enables operation in the local network of
chargers. This enables the Enelion DLB function to be activated for dynamic
load balancing, thus reducing the number of devices that require an Internet
connection and optimizing the use of power in charging vehicles.
All Enelion devices can be fitted with Enelion Bridge (an add-on to be
purchased separately). It equips the devices with Smart functions and
facilitates their connection to a remote management system (OCPP 1.6
compliant) via the Internet.
INFO The operations described below are identical for the device already
mounted on the wall. Please note that the device must be opened at least once
before the installation to allow access to the mounting holes on its back and
to connect the power cable.
1. Remove the rubber plugs from the top left and right hole of the device.
2. Insert the supplied Allen key into the exposed hole. The key should be
inserted until resistance is felt, i.e. until it cannot be pushed deeper.
5
General information
Wallbox – Assembly manual
7 – 2022
5. Holding the socket housing, pull the bottom edge of the panel until it is
released from the housing and tilted slightly.
Fig. 2: Inserting an Allen key.
3. Turn the key counterclockwise until the locking pin is aligned with the side of the charger. Remove the Allen key from the hole. Repeat action number 2 for the second locking pin.
Fig. 5: Front panel slightly tilted.
6. Holding the front panel in the same plane, slide it downwards from the top
frame of the device.
Fig. 3: Unscrewing the locking pin.
4. Slide the front panel upwards of the device by holding the socket housing
use a suction cup as an option until the lower edge of the front panel is
exposed.
Fig. 6: Removing the front panel from the device housing.
7. Slowly continue to pull out the front panel, watchful of the socket lock
not hooking onto the housing.
Fig. 4: Front panel moved upwards. 6
Fig. 7: Pulling out the front panel. General information
Wallbox – Assembly manual 8. The front panel may freely rest next to the
housing, hanging within the reach of the socket connection wires.
Fig. 8: The device open with the access to its interior. INFO The panel is
fitted into place by following the above operations in the reverse order.
WARNING Be careful not to crimple the signal tape while fitting the front
panel.
7 – 2022
7
General information
Wallbox – Assembly manual
7 – 2022
3. Design indications of the installation
3.1. Recommended power connection
Enelion charging stations are adapted to five-wire power supply from TN-S type
and TT type grid. It is possible to apply three-wire power supply from TN-S
type grid.
Cables running underground must be installed in accordance with the binding
building regulations. For convenient installation, flexible power cables,
stranded type, terminated with clamping sleeves are recommended
INFO
WARNING
Connection possibilities have been described in “User manual”, in the Device
configuration section.
In case of single phase installation, the maximum cross-section of the power supply cable to be assembled in connection terminals is 10 mm2. The diameter of the power supply cable with insulation must not exceed 16 mm.
Enelion charging terminal must be powered from the electrical switchboard. The
board must have the required protections in the form of an overcurrent circuit
breaker with B or C characteristics and rated current of 32 A or lower,
appropriate to the device version. To be compliant with the PN-EN IEC 61851-1:
2019-10 standard, each charging point must also be protected against type A or
B residual current. This requirement must be met by one of the below:
1. installation of a type B residual current device (RCD B 30 mA/40 A) or RCD
EV (30 mA/40 A) in the switchboard,
WARNING
To supply the voltage to the installed and connected charging station, first
switch on the RCD protection, and next the overcurrent switch.
For installation, about 50 cm of power cable reserve from the expected
installation position is recommended. For Wallbox Adspace devices, a reserve
of about 110 cm of the cable supplying power to the left socket is
recommended.
2. installation of a type A residual current device (RCD A 30 mA/40 A) in the
switchboard with the application of Enelion RCM B type B Residual Current
Monitor, attached to the charging terminal.
The final selection of the safety devices belongs to an authorized designer or
a qualified electrician.
The above requirements result in the necessity to use independent cables for
multi-socket devices: Wallbox Duo Power and Wallbox Adspace.
3.2. Recommended communication network
Enelion devices support the Enelion Chain communication interface. For its
implementation, a wired connection between the devices is required using an
Ethernet CAT 5 or CAT 6 cable.
For installation, leave about 50 cm of communication cables from the expected
installation position.
The network works in a serial topology where:
Wallbox Duo multi-socket device allows one to power the charging sockets only
in 1-phase mode. Therefore, it should be powered with one four-wire cable.
The cross-section of the power supply cables must be selected by an authorized
electrician, depending on the distance from the switchboard and other
conditions pertinent to the location. To obtain the maximum charging power in
wall-mounted devices, the use of cables with a conductor cross-section not
greater than 6 mm2 is recommended. The diameter of the power supply cable with
insulation must not exceed 16 mm.
· the number of Enelion charging points does not exceed 100 devices,
· the total length of the communication cable connecting the devices does not
exceed 500 m.
Fig. 9: Enelion Chain network topology.
8
Design indications of the installation
Wallbox – Assembly manual
7 – 2022
Enelion devices equipped with the Enelion Bridge module can use the Internet
connection via the Ethernet interface in the LAN network. In order to utilize
this function, run the Ethernet CAT 6 cable to the device in which the use of
this option is expected.
INFO
Devices equipped with Enelion Bridge can also use WiFi and GSM interfaces to
ensure the Internet connection, but they do not have requirements related to
cable installation.
3. 100 cm clearance below the bottom edge of the device.
WARNING
The manufacturer accepts no responsibility for any damage resulting from
failure to comply with the above-mentioned recommendations.
3.3. Location selection criteria
Wall-mounted Enelion devices may be installed both internally or externally.
The device has been designed to be installed near parking spaces for electric
vehicles. When used in the vehicle collision hazard zone, the structure should
be secured with appropriate fenders painted in yellow and black stripes
(warning about the gauge). Bear in mind that the national regulations may
define the space for the installation. The device should not be located in a
place of high exposure to sunlight, which could cause overheating. Do not
install the device near heat sources or in small, closed spaces (e.g. in a
box).
It is forbidden to install a power cord that does not comply with the
guidelines in section 3.1 Recommended power connection. It is forbidden to
install the device in potentially explosive environment. Local regulations for
electrical installations, fire prevention measures and accident prevention
must be taken into account, and escape routes at the installation site must be
provided.
It is forbidden to install the device in a location where falling objects may
damage the charger.
Before installation, make sure that the mounting space for the device is
sufficient. Wallbox family devices should have at least:
1. 10 cm clearance on each side of the unit.
Stilo family devices should have at least:
1. 10 cm clearance on the right side of the unit.
2. 50 cm clearance above the top edge of the device.
9
Design indications of the installation
Wallbox – Assembly manual
4. Assembly
WARNING Before commencing the installation, switch off the power supplied to
the cables.
7 – 2022
4.1. Preparing the installation
1. Place the packaged Enelion Wallbox Easy horizontally, in accordance with the markings on the packaging. Cut the package open along the indicated line. Take the device out of the cardboard box, remove the polystyrene protective casing and put the device in the correct horizontal position.
Fig. 10: Mounting holes as seen from the back of the device.
2. The polystyrene protection contains useful accessories required for the mounting of the device. Before recycling the packaging, collect those accessories that include:
Follow the information listed below to choose the appropriate method of
assembly, depending on the mounting surface:
1. four mounting holes are positioned on the plan of a rectangle with
dimensions of 230 mm x 96 mm (width x height),
· 3 mm Allen key,
2. mounting holes have a diameter of 5,5 mm,
· cable gland plug, · RFID configuration card and RFID pendant.
3. Open Enelion Wallbox in accordance with the instruction included in
section 2.1 Opening and closing Enelion Wallbox.
4.2. Selection of bolts and anchors
Enelion Wallbox is mounted on vertical surface using bolts. The device has
four mounting openings.
3. the device weighs between 3 kg 3,5 kg,
4. mounting must provide stability for the device to withstand significant
forces affecting it when plugging and unplugging the charging cable in the
socket.
WARNING
Use all mounting holes in the process of installation. Failure to do so will
result in the loss of water and dust resistance of the device, classified, as
a default, as IP 54. This can lead to damage or failure of the charger, and
consequently to loss of life or health. The manufacturer is not responsible
for damage and injuries arising from failure to observe the above
recommendations.
10
Assembly
Wallbox – Assembly manual
4.3. Cable routes
7 – 2022
The default power cable entry is at the top of the device.
It is possible to insert the power cable from the bottom of the device by
moving the gland by oneself. To do this, remove the plug on the bottom of the
device.
The insertion of communication cables is possible from the bottom of the
device. This requires the removal of the plug and the installation of a gland
suitable for the type and number of communication cables to be routed. The
opening diameter for the communication cable gland is 19 mm.
Fig. 12: Removing the plugs for cable entry openings.
The cable gland in the upper part of the device should be put into the hole in
the lower part of the device and screwed to ensure tightness. The gland nut
requires a 32 mmspanner and the gland requires a 30 mm spanner. After
repositioning the gland, the opening in the upper part of the device should be
closed with the additional plug provided with the product.
Fig. 11: Locations of cable entry points in Enelion Wallbox.
The removal of plugs for the assembly of cable glands should be performed
according to the following guidelines:
1. place the device on a stable surface,
2. use a hammer and a flat-bladed screwdriver to Fig. 13: Additional plug with a nut provided with the
knock out the gland hole plug carefully.
product.
11
Assembly
Wallbox – Assembly manual
7 – 2022
4.4. Mounting the device
INFO The device has been equipped with a template facilitating the
installation.
Fig. 14: Mounting place for the additional plug.
Fig. 15: Mounting method for the additional plug. The cable gland for
communication cables should be installed in accordance with the manufacturer’s
instructions.
1. Determine the final location of the device using the attached template and
the level, and mark the mounting holes. The template marks the mounting holes,
the outline of the rear wall of the device, the axis of the glands (both in
the version with a gland in the upper and the lower part of the device) and
the optimal cable lengths. Mounting holes should be at least 5 cm from the
edge of the wall (in case of a recess, minimum 20 cm — to leave enough space
for the use of Allen key). The axis of the power cable must coincide with the
axis of the glands marked on the template. Make sure that the power cord is at
least 350 mm long, measured from the edge of the device marked on the
template.
2. Make assembly holes and install expansion bolts. Mounting holes should be
made in accordance with the specification of expansion bolts, which should be
placed in the cleaned holes.
3. Make sure that there is no voltage in the power cords.
4. Open the device as described in section 2.1 Opening and closing Enelion
Wallbox.
5. Put the device in the target position by threading the power cable through
the glands.
6. Fasten the device with screws using a screwdriver with a shaft length of
at least 150 mm.
7. Screw on the power cable gland ensuring tightness.
8. (Optional) Insert at least 350 mm of the communication cables into the
device.
WARNING
To make sure the device is water-tight in accordance with IP54 class and keep
the manufacturer’s warranty for the device, after relocating the cable gland
from the top to the bottom of the device, the unused hole must be secured with
a plug and a nut set included with the device.
The device mounted in this way can be connected.
12
Assembly
Wallbox – Assembly manual
7 – 2022
5. Connection
5.1. Power connection
Enelion Wallbox comes in various types. Depending on which type is being
installed, the power supply cables
may be connected directly to the terminals or to the approved integrated MID meter.
Fig. 16: Schematy wariantów podlaczenia 1./2.
13
Connection
Wallbox – Assembly manual
7 – 2022
Fig. 17: Schematy wariantów podlaczenia 2./2.
5.1.1. Standard power connection
1. Prepare the power supply cable. Remove 200 mm of the main insulation off
the power supply cable. Terminate the individual
wires of the cable with fork (M4 or M5 size) or sleeve terminals.
2. Insert the power supply cables into the terminals.
14
Connection
Wallbox – Assembly manual Fig. 18: Connection using fork terminals
7 – 2022
2. Insert the power cables into the terminals of the MID meter and tighten
them. Unless otherwise marked on the label of the device, make a standard
connection in accordance with the markings on the meter. The PE protective
conductor should be connected to the prepared coupling.
Fig. 19: Connection with solid conductors wire
3. Use a PZ2 end screwdriver to tighten the terminals with 1,5 N m torque.
Fig. 21: Recommended connection when applying a MID meter.
MID meter communication connection should be done Fig. 20: Electrical
connection executed correctly. according to the diagram below:
INFO
It is also possible to use a three-wire power supply in a TN-S network. The
possible connection methods for the device are described in the User Manual in
the section titled Device Configuration.
5.1.2. Power connection in version with MID meter
1. Prepare the power cord. Remove 200 mm of the main insulation off the power
supply cable. Terminate the individual wires of the cable with sleeve
terminals.
15
Fig. 22: MID meter communication connection. Connection
Wallbox – Assembly manual
7 – 2022
HINT
HINT
The colors of the phase wires in Enelion Box may not match the colors of the power cables, maintaining, however, the guidelines on Enelion Wallbox label. This is a correct and expected situation when using the phase sequence function.
The way of cables through the RCMB hole does not matter. The RCMB monitor
could be freely assembled on the socket cables or on the main income cables.
INFO
5.1.3. RCM B Connection
Enelion RCM B Residual Current Monitor type B accessory. Enelion RCM B in
combination with the RCD A used in the switchgear meet all safety
requirements.
More information in the User Manual.
1. Connect the device to the dedicated socket on
the PilotBox board. [Fig. 20]
5.2. Enelion Chain
If the communication between the devices is expected to be via Enelion Chain network, the cables should be connected to the charge controller. Two cores of the communication cable and the screen grounding are used for communication. To connect correctly:
1. Prepare communication cables
Fig. 23: PilotBox RCM B socket.
2. Pass through the RCM B hole four powering cables (All three phases and
neutral cord.)
2. (a) for devices at the beginning of the network, select a pair of
communication wires,
(b) for devices in a section of the network, prepare the communication cables
inserted into the device by connecting together the cores of the incoming and
outgoing wires (in variant A) or move to the next step (in variant B, check
figures below).
Fig. 24: RCM B connection 16
Fig. 25: Incoming and outgoing communication cable connection (variant A)
Connection
Wallbox – Assembly manual
7 – 2022
4. Use termination for devices at the beginning and end of the network. In
case of variant A place terminating jumper on the marked headers [Fig 28]. In
case of variant B termination is done by slide the switch down, to show white
square. In alternate version, if there is no switch, place a jumper on two
pins in the header inside the charger marked by white line [Fig. 29].
Fig. 26: Incoming and outgoing communication cables (variant B)
3. Release the connector terminal by pressing the button using a flathead
screwdriver and insert the wires into the respective locations. There will be
single wires for devices at the start and end of the network.
Fig. 29: Termination diagram.
Fig. 27: Diagram of Enelion Chain communication cables connection (variant A)
Fig. 30: A sample jumper.
Fig. 28: Diagram of Enelion Chain communication cables connection (variant B)
17
Fig. 31: The place of applying the terminating jumper (variant A)
Connection
Wallbox – Assembly manual
7 – 2022
Fig. 32: The place of applying the terminating jumper (variant B)
5.3. Internet connections via Ethernet interface in LAN network
To provide the Internet connection to a charger equipped with Enelion Bridge
module via Ethernet interface:
1. Insert the Ethernet cable into the device through the gland for
communication cables.
2. Terminate the cable with the RJ45 connector according to TIA-568A/B to
100BaseT.
Fig. 34: Enelion Bridge module diagram.
Fig. 33: Termination of the Ethernet cable according to TIA-568A/B to
100BaseT.
3. Connect the Ethernet cable to the WAN/INTERNET socket of Enelion Bridge
module marked with number 2.
18
Connection
Wallbox – Assembly manual
6. Maintenance
The device is designed to operate in temperatures from -25 °C to 55 °C. The
manufacturer does not guarantee the proper functioning of the charging station
in temperatures outside the specified range. Chargers that are damaged because
of exposure to temperatures below -25 °C or above 55 °C are not covered under
the warranty. In case it is necessary to open the device, make sure that it is
disconnected from the power source. With the device installed outdoors, make
sure that there is no precipitation or strong wind.
WARNING
The device may only be opened by a qualified and authorized person.
6.1. Cleaning
The correct way to clean the charger is to wipe the housing with a microfiber
cloth using a cleaning agent dedicated to anodized aluminum. Plexiglas
elements (front panel) and plastic elements (socket) should be cleaned with a
microfiber cloth using a cleaning agent dedicated to cleaning windowpanes.
Other cleaning methods (e.g. wire brush) may lead to the damage of the device
housing. Damage resulting from improper cleaning of the device does not
constitute grounds for warranty claims.
WARNING
The device meets the IP 54 standard. Therefore, it is forbidden to wash the
charger with pressure washers, garden hoses, shower or any other water stream
sources.
7 – 2022
19
Maintenance
Wallbox – Assembly manual
7. Technical data
7.1. Enelion Wallbox
Electrical data Routing of the power cord Power cord cross-section Supply
voltage (Europe) Voltage frequency Network type Overvoltage category Rated
short-circuit current Overcurrent protection
Protection Class Socket type
Mechanical data Dimensions (width x height x depth) Weight IP Class Mechanical
strength class
Interfaces Charging network development
Add-ons
RFID
7 – 2022
Surface mounted Recommended minimum cross-section
· 5 x 6,0 mm2 (32 A nominal current) 3 x230 V/400 VAC (+-10%) 50 Hz/60 Hz TN,
TT (IT per special request) III according to EN 606641 Effective value < 6 kA
according to EN 614391 Not included. Protection to be made in accordance with
the locally valid regulations and according to the type of the device. Class I
Type 2, standard socket 32 A/400 VAC in accordance with EN 621961
271 mm x 249 mm x 144 mm 3,1 kg 5% IP54 IK10
Enelion Chain · Enelion MID · Enelion Bridge · Enelion RCM B
MIFARE cards compliant with ISO 14443
20
Technical data
Wallbox – Assembly manual
Ambient conditions Working temperature Storage temperature range Permitted
relative air humidity Elevation above the sea level
from -25 °C to 55 °C from -40 °C to 80 °C from 5% to 95% maximum 2000 m
7 – 2022
Signs of installation faults Damaged varistors on PilotBox
It means faulty connection powering cords
WARNING
Above information may be the basis for exclusion of warranty.
21
Technical data