enelion Lumina 3 In 1 Modular Structure Installation Guide

June 2, 2024
enelion

Lumina 3 In 1 Modular Structure

“`html

Specifications

Housing: Polycarbonate, anodised aluminium,
powder coating*

Ingress protection rate: IP54

Impact protection: IK10

Flammability class: UL94-V0

Charging connector type: Residual current
protection

Embedded residual current monitor: Enelion RCM
B 6 mA DC

Energy metering: Integrated 3-phase energy
meter > 99% accuracy

Certified electricity meter (MID)

User interface: Online communication unit OCPP
communication protocol

Multi-colour LED strip: EVC status indication;
Dedicated app

Integrated LTE/4G modem: Hide the AP and
connect the station to local Wi-Fi network; Compliance with OCPP
1.6 J protocol

Minimal signal quality requirements: Wi-Fi: -60
dBm GSM: -85 dBm

Authorization: Dedicated app

Current/Charging power: Up to 7.4 kW at 32 A
1-phase

Product Usage Instructions

Before Installation

Please read the manual before installation. Ensure you have all
the necessary tools and safety screws.

Preparation for Installation

Prepare the device for installation by checking ENELION LUMINA
SOCKET, ENELION LUMINA ALU SOCKET, and ENELION LUMINA ALU CABLE
components.

Installation Process

Follow the step-by-step guide provided in the manual for
installing the charger. Use the diagrams of connection variants and
overview diagrams of modules for reference.

Power Supply Network Systems

Ensure proper electrical connection and consider alternative
methods for inserting power cables if needed. Use the M20 gland
adapter for secure connections.

Ethernet Connection

Establish a wired communication in ENELION LUMINA for network
connectivity. Follow the instructions for connecting to
Ethernet.

Start-up and Configuration

After installation, proceed with the start-up and configuration
of the station as detailed in the manual. Configure additional
settings as needed.

Daily Use and Operation

To charge your device, follow the instructions provided in the
manual. Monitor the interface LED for charging status and refer to
the maintenance section for cleaning guidelines.

FAQ

How do I charge my device?

To charge your device, connect it to the ENELION LUMINA charger
following the provided instructions. Monitor the LED interface for
charging status.

What are the safety features of ENELION LUMINA?

The ENELION LUMINA charger includes safety screws and embedded
residual current protection for user safety. Refer to the safety
instructions in the manual for more details.

“`

Installation guide
Video tutorial
ENELION LUMINA
3 in 1 modular structure — build and upgrade your dreamed solution using the same base module. Quick installation — get your EV charger ready to work online in no more than 15 minutes of the installation process.

Dear Partner,
Congratulations on your purchase of the Enelion charger and thank you for your trust.
Up-to-date manuals for users and installers always available at: https://enelion.com/support-lumina/
Please read this manual before installation or prior to the station being commisioned.

Introduction

6

Table of content

Additional tools necessary for installation

6

Optional safety screws

7

Features

8

Technical specifications

9

Safety instructions

11

Before the installation

13

How to prepare the device

for installation

14

ENELION LUMINA SOCKET

14

ENELION LUMINA ALU SOCKET

15

ENELION LUMINA ALU CABLE

16

Installation

17

Diagrams of connection variants

17

Overview diagrams of modules

18

Preparation

18

Power Supply Network Systems

18

Installation of mounting plate

21

Electrical connection

21

Alternative method for the insertion of power cables

23

M20 gland adapter

24

Measuring a 230 V socket.

25

Ethernet connection.

27

Wired communication in ENELION LUMINA.

27

Table of content

Step by step

29

Start-up and configuration of the station

33

Additional information for

the UK market

34

Pen Fault Detection

34

Daily use and operation 35

How do I charge?

35

Interface LED

36

Maintenance

36

Cleaning

36

Practical details

37

Customer service

39

ENELION LUMINA products family

ENELION LUMINA
BACKPLATE

ENELION LUMINA ALU CABLE

ENELION LUMINA ALU SOCKET

CLOSED
ENELION LUMINA SOCKET

OPENED 5

Introduction
Additional tools necessary for installation

x6 x6

max. 5 mm

5 mm

PH2 + PH3 PZ1 + PZ2 + PZ3 T10 + T15 + T20

6

Optional safety screws
Each charger kit includes safety screws (additionally secured with a pin to prevent unauthorized access) that can replace the standard screws attaching the top part of the head to the back, if needed. The appropriate bit is optionally available as an accessory or can be purchased separately (size T10H x 25 mm).
i
If you need the appropriate bit, you can order it from us under the index AKCBIT-010.
7

Features
LED INTERFACE LTE
ROOM FOR OPTIONAL ETHERNET MODULE
ROOM FOR OPTIONAL 230 V CEE 7/3 SOCKET 8

RFID CARD READER
SOCKET TYPE 2 WI-FI
ROOM FOR OPTIONAL CERTIFIED ENERGY METER

Technical specifications

Housing

Polycarbonate, anodised aluminium, powder coating*

Ingress protection rate

IP54

Impact protection

IK10

Flammability class

UL94-V0

Charging connector type Residual current protection

Enelion LUMINA SOCKET ­ Type 2 socket, Enelion LUMINA ALU CABLE ­ Type 2 connector with 5.2 m cord
Embedded residual current monitor – Enelion RCM B 6 mA DC

Energy metering

Integrated 3-phase energy meter > 99% accuracy

Certified electricity meter (MID)

Impulse* ­ possible to install inside the housing

User interface Online communication unit OCPP communication protocol

·

Multi-colour LED strip EVC status indication;

·

Dedicated app

·

Integrated LTE/4G modem

·

Wi-Fi 2.4 GHz b/g/n ­ direct access point to the station with an option to

hide the AP and connect the station to local Wi-Fi network

compliance with OCPP 1.6 J protocol

Minimal signal quality requirements

· ·

Wi-Fi: -60 dBm GSM: -85 dBm

Authorization

·

Built-in RFID/NFC reader ­ Mifare Classic/Freecharge Mode

·

Dedicated app

Current/Charging power

·

Up to 7.4 kW at 32 A 1-phase

·

Up to 22 kW at 32 A 3-phase (TN system)

Charging voltage

3 x 400 V AC/230 V AC (±10%)

9

Supply voltage
Other features Operating temperature Maximum altitude for installation Height Depth Width Weight
Compliance

3 x 400 V AC/230 V AC (±10 %) (TN/IT) Possibility of connecting the cable from the top, bottom and the back of the station

·

Configuration with no additional tools

·

Remotely controlled 230V socket (max. 2000W/10A)*

·

Temperature and humidity monitoring inside device

·

Remote start/stop, delayed start and end of charging

From -30°C to +55°C 2000 m

390 mm

133 mm

155 mm

3.3-8.9 kg (depending on device version)
2014/53/EU (RED); 2011/65/EU (RoHS), 2014/30/EU (EMC) ; 2014/35/EU (LVD); UK SI 2016 No. 1101; UK SI 2016 No. 1091; UK SI 2017 No. 1206; UK SI 2012 No. 3032

The following BSI and ETSI standards and technical specifications have been applied:

ETSI EN 300 328 V2.2.2:2020-03; EN 62196-2:2017-06; EN IEC 618511:2019-10; EN IEC 61851-21-2:2021-09; EN 62196-1:2015-05; ETSI EN 301 511 V12.5.1:2017-10 ETSI EN 300 330 V2.1.1:2017-08; ETSI EN 301 489-1 V2.2.3:2020-07; ETSI EN 301 489-17 V3.2.4:2021-05

  • Option 10

Safety instructions
The Enelion charger (hereinafter referred to as the device, charger, or charging terminal) is a charging station designed for electric vehicle charging within the meaning of the `Act on Electromobility and Alternative Fuels’ dated January 11, 2018, in paragraphs 5, 12, 13, and 27 of Article 2 of the aforementioned act.
The installation and servicing of the device must be carried out by qualified and authorized individuals, and repairs may only be performed by the manufacturer or entities authorized by the manufacturer. During the warranty period, only authorized service centers and the manufacturer are allowed to perform warranty repairs.
Interference with mechanical, electrical, and electronic components, as well as the device’s software, is strictly prohibited and may void the warranty. Exceptions are actions described in the following instruction manual or those agreed upon in writing with the manufacturer.
The manufacturer is not responsible for property damage resulting from prohibited interference with the product.
The electrical installation to be used during device operation must meet the conditions described in the installation manual. The manufacturer is not responsible for incorrect execution and/or protection of the electrical installation to which the device is connected.
The manufacturer is not responsible for the improper functioning of the electrical installation

to which the device is connected.
The electrical installation to be used during device operation must comply with the legal standards applicable at the installation and operation location of the device.
The manufacturer is not responsible for damages caused by an electrical installation that does not comply with legal standards.
The device does not have a built-in power switch.
The device is activated when the power supply voltage is applied. Power disconnection must be ensured by appropriate devices in the electrical installation described in the installation manual. Except in emergency situations, the device should not be switched off during the charging process.
It is prohibited to power on the device when the device housing is open.
It is prohibited to use a charger that is mechanically damaged or indicates a critical error.
Objects not intended for this purpose must not be placed in the charger socket. The only object intended for insertion into the charger socket is a functional power cable with the appropriate power and type for the electric vehicle, terminated with a functional type 2 plug according to EC 621962.
The use of extension cords, adapters, and charging cable extensions is prohibited.
The manufacturer is not responsible for loss of health or life resulting from non-compliance with the above recommendations.
11

During the warranty period, the manufacturer allows the purchase of support packages for the device (extended warranty/service) subject to a qualifying review before purchasing the package. Details can be obtained from the Enelion sales department. The charging station does not support ventilation functions. The nameplate present on the device is an integral part of it and must not be removed or damaged, as this may result in the loss of the manufacturer’s warranty.
i
Three self-adhesive labels with information about the current value have been included in the set. Please select the appropriate one according to the specifications and affix it next to the nameplate.
12

Before the
installation
· This product may only be installed, repaired or serviced by an authorized electrician. All local, regional and national electrical installation regulations must be observed. It is recommended to consider future charging needs before installation.
· The power supply to the Enelion charging terminal must be provided from an electrical switchgear. The switchgear must have the required protection in the form of a type B or C over current circuit breaker and a current rating of 32 A or less, suitable for the configuration of the device. To declare compliance with EN IEC 61851-1:2019-10, each charging point must also be individually protected against Type A and Type B residual current. This requirement must be fulfilled by one of the following: 1. Installation of a type B residual current device (RCD B 30 mA/40 A) or RCD EV (30 mA/40 A) in the switchgear, 2. Installation of a residual current device type A (RCD A 30 mA/40 A) in the switchgear using the Enelion RCM B ­ Residual Current Monitor type B provided on the charging terminal.
· The final selection of the protective equipment must be made by an authorized designer or qualified electrician.
· For maximum charging power, it is recommended to use cables with a conductor cross-section not exceeding 6 mm2. This is also the maximum diameter that can be installed in the connection terminals. For convenient installation, flexible power cords

of the wire type terminated with collets are recommended. · A residual current monitor (RCM) can be integrated into the Enelion LUMINA charger. This will switch off the current to the electric vehicle if: a residual current of 4­6 mA DC occurs. The RCM is reset by disconnecting the charging cable and reconnecting it.

Load

Charging power

Charging 1 phase current (kW) (A)

3 phase (kW)

6

1.4

4.1

8

1.6

5.5

10

2.3

6.9

13

3.0

9

16

3.7

11

20

4.6

13.8

25

5.8

17.3

32

7.4

22

The table above shows what charging power you can expect from your installation.
The table is for information purposes only.

13

How to prepare the device for installation
ENELION LUMINA SOCKET 2
1

02 Slide out the head module and remove the housing cover

2 1

01
14

Undo two long bolts and two screws at the bottom (1). Repeat with two screws at the top (2)

03 Unscrew the fixing screws and remove the transparent cover

ENELION LUMINA ALU SOCKET 2

1

02 Slide out the head module

1 2

01 Undo two long bolts at the bottom (1) and two screws at the top (2)

03

Unscrew the fixing screws and remove the transparent cover
15

ENELION LUMINA ALU CABLE 3 1

1 2
3

2

02 Slide out the head module

01
16

Dismantle the cable holder (1). Undo two long bolts at the bottom (2) and two screws (3) at the top

03 Unscrew the fixing screws and remove the transparent cover

Installation
Do not carry out outdoor installation during rain or strong winds if there is a risk that water or debris may enter the device.
All of the operations described in this manual should be carried out after making sure that there is no voltage in the power cord.
This product may only be installed, repaired or serviced by an authorized electrician. All local, regional and national electrical installation regulations must be observed.

01 Diagrams of connection variants

Enelion LUMINA Backplate

Enelion LUMINA Backplate

Output connector
Terminal block

Output connector
Terminal block

Cable line

Video tutorial https://enelion.com/support-lumina/
In addition to the steps described on the following pages, we recommend watching the installation videos.

Main switchboard

32 A/6 kA

Billing meter

30 mA/40 A

30 mA/40 A
17

02 Charging module Type 2 socket with RCM B 6 mA DC

Overview diagrams of
modules

5×6 mm2

H0

5 C 1000 V

275 V AC

Charging module

Input connector

Type 2 socket with RCM B 6mA DC

H07Bz5-F5G 6,0 mm2 + 1×0,75 mm2 450/750 V

Type 2 socket

03 Preparation
In the box with the Enelion LUMINA charger, you will find an assembly template to help you choose the installation location and prepare the installation holes.
We recommend that you position the station so that the top edge of the charging station is approximately 130 cm from the floor.
The electrical cable can be connected to the station from above, from below and directly from behind the station at the gland marked on the template.
The design of the station allows both wall and pole installation (additional installation components required ­ sold separately). We suggest that there is local Wi-Fi network coverage at the station installation site and/or LTE mobile network coverage if the station is to be used online.

03.1 Power Supply Network Systems

Enelion charging stations are designed for five-

wire power supply. In a TN-S 230/400V network,

Input connector

this is the standard option.

18

TN-S 230/400 V
Generator or transformer

Grounding

MCB RCD
L1 L2 L3 N PE
EVSE

L1

Phase-Phase

L2

400 V

L3 Phase-N 230 V
N

PE

TN-C
Generator or transformer

Grounding

L1 L2 L3 N PEN
Load

It is possible to power the station from other network systems described below:

TT 230/400 V
Generator or transformer

Grounding

MCB RCD
L1 L2 L3 N PE
EVSE

L1

Phase-Phase

L2

400 V

L3 Phase-N 230 V
N

Grounding

TN-C
Generator or transformer

Grounding

L1 L2 L3 N PEN
Load

L1

L2

Phase-Phase

400 V

L3 Phase-N
230 V
PEN

L1

L2

Phase-Phase

400 V

L3 Phase-N
230 V
PEN

In the TN-C system configuration, you should separate the PEN conductor into N and PE as shown in the diagram below.

In the case of an IT network with 120/230 V, as found in Norway, the connection appears as follows.
19

It should be noted that one of the phases serves as the Neutral conductor, which is important during the installation of RCD (Residual Current Device). In such a network, it is not possible to charge in three phases; only some vehicles will be able to charge in two phases.

IT 120/230V
Generator or transformer

L1

L2

Phase-Phase

230 V

L3

Phase-PE

PE

120 V

High Z Grounding

MCB RCD
L1 L2 L3 N PE
EVSE

Grounding

It is not possible to power the station from an IT network with 230/400V.
IT 230/400 V NOT ALLOWED!!!
Generator or transformer

L1

Phase-Phase

L2

400 V

L3 Phase-PE
230 V PE

High Z

Other, more complex power systems require technical consultation before purchase.

Grounding

L1 L2 L3 N PE
EVSE

Grounding

20

04 Installation of mounting plate
!
Turn off the power before installation.
1. Connect the electrical cable. 2. Hang the mounting plate according to the
template. 3. Secure electric cable in the gland.

05

Electrical connection

For maximum charging power, it is recommended to use cables with a conductor cross-section not exceeding 6 mm2. This is also the maximum diameter that can be installed in the connection terminals. For convenient installation, flexible power cords of the wire type terminated with collets are recommended.

Installation of the cables in the station cable terminals does not require any special tools.

!
The label placed on the connectors indicates the sequence of connecting phase wires. To connect the wires, remove the label.
21

1-phaze

3-phaze 1-phaze
3-phaze

!
It is recommended to use the existing colour code used in the wiring. Depending on the standard in your country, the cable colours may differ from those shown.
!
Before switching on the power, make sure that the cables are connected correctly. Test this by pulling on each wire.
After preparing the installation, close the transparent cover.

22

06 Alternative method for the insertion of power cables
If it is not feasible to insert the power cables in the standard way, an alternative method can be applied.
In the lower part of the rear housing of the station (if it is not equipped with the optional 230 V socket), there is a hole for an M25 cable gland with a blanking plug.

If necessary, the installer can remove the blanking plug and insert the removed cable gland from the standard installation variant in its place.

!
In order to maintain the warranty, the previously removed plug must be installed in place of the originally installed cable gland.
23

07

M20 gland adapter

For the alternative method of inserting power cables into the station, an adapter with a hole for M20 gland is available separately ­ it can be used to install a special gland with an armoured cable in case of a single-phase system.

M20

Hole for M20 gland

Blanking plug in place of originally installed cable gland
24

08 Measuring a 230 V socket.
There are two options when it comes to measuring a 230 V socket.
1. Use a single-phase MID meter. To do this, you should connect the socket to the meter according to the diagram shown in the drawing.
The charger’s power supply is connected directly to the board presented in chapter 5.

Measuring energy consumption solely through a 230 V socket.

Enelion Lumina Backplate

230V RCMB MID socket terminal terminal terminal

Power connection
terminal
L2

Energy meter

-+

socket

fuse*

Energy meter
Fuse
Distribustion board *0234010.MXP (Cartridge Fuse 250V 10a Medium Acting)
Electrical connection of ENELION LUMINA in the case of measuring a 230 V socket.
25

Enelion Lumina Backplate

230V RCMB MID socket terminal terminal terminal

Power connection
terminal
L2

Energy meter

-+

socket

fuse*

2. Measuring the Type 2 car charging socket and the 230V socket.
In this case, you should connect it according to the diagram next to it.

Energy meter Fuse
Power connection in the case of measuring the entire ENELION LUMINA charger.
26

!
We do not recommend using a 230 V socket for charging your car because it may overload the connection.
More information related to measuring the 230 V socket can be found in the user manual.

09 Ethernet connection.
The Ethernet module is installed in ENELION LUMINA chargers on the back of the device on the left side. The Ethernet cable can be routed through a special opening in the back cover and is secured against being pulled out by a special clamp installed in the charger.

The opening in the back cover of ENELION LUMINA is designed for cables with a maximum outer diameter of 6 mm.

After installing the Ethernet cable, you should activate the Ethernet module in the configuration panel following the instructions provided in the user manual.
10 Wired communication in ENELION LUMINA.
Wired communication in ENELION LUMINA is based on a serial, wired CAN bus. For installation, it is recommended to use a CAT5e or better Ethernet cable with copper conductors, not CCA – Copper Clad Aluminium.
Communication utilizes a single twisted pair of wires and the shield of the cable. The total length of the cable must not exceed 500 meters. The socket for connecting the CAN communication cable is shown in figure:
27

i
Due to differences in the implementation of CAN communication in ENELION LUMINA chargers and Enelion Wallbox, Vertica, and Stilo chargers, it is not possible to connect them in a single chain.
To terminate, use the switch shown in the diagrams in devices located at the beginning and end of the charger chain.
Termination activated.
Termination desactivated.
28

11 Step by step

01 02 Level the template ­ mark the holes

Drill holes ­ insert pins

03 Screw the backplate to walls ­ tighten the cable entry

04 Remove the insulation from the cable

05 Connect wires

29

05a

Enelion LUMINA

with optional

230 V CEE 7/3 SOCKET

and optional CERTIFIED

MODEL LB-32-3-X-1-X-XX-MGR-00

ENERGY METER

!
The presented connection is exemplary. Before installation, check the markings on the mounted meter.
30

05b
MODEL LB-32-3-X-1-X-XX-GR-00

Enelion LUMINA with optional 230 V
CEE 7/3 SOCKET

31

Slide

ENELION LUMINA ALU SOCKET

06 07 Install the transparent cover using four screws.

Insert SIM card

08a Mount the head on

ENELION LUMINA SOCKET

08b Tighten the head ­ two long bolts at the bottom and two screws at the top
32

Slide from the front

09a 09b Install front cover

Use two long bolts and two screws at the bottom and two

screws at the top

08

Start-up and configuration of the station

Switching on the safety devices, which turns on the voltage at the station, should be carried out by a suitably qualified person.
Using a smartphone or computer, search for the LUMINA station’s AP with the SSID listed on the back of the charging head.
After connecting to the LUMINA station’s AP with the SSID and password given on the back of the charging head, type the following into the address bar of your browser: http://192.168.8.8
http://192.168.8.8

Access to the configuration panel is protected by a password, which by default is admin.
It is also possible to log into the simplified version of the panel via your user account and password user.
The password should be changed if necessary.

http://192.168.8.8

The configuration process should be carried out according to the instructions on the panel.
33

Additional information fmfmooaarrrrttkkhheeeettUUKK
This section outlines the information for installation of Enelion LUMINA in the UK region.
Part Numbers Affected: Heads: LH-32-1-X-0-S-04-EO-00, LH-32-1-S-0-S-04EO-00; LH-32-1-B-0-S-04-EO-00; LH-32-1-S0-C-50-EO-00; LH-32-1-B-0-C-50-EO-00
!
The label placed on the connectors indicates the sequence of connecting phase wires. To connect the wires, remove the label.
!
Connection for Pen Fault Detection configured charger Head. Pay attention to different connection of PE conductor!
34

01

Pen Fault Detection

To follow and be compliant with the regulations specified by IET in clause 722.411.4.1 (iv), Enelion LUMINA uses a technology that enables you to directly connect your charger to a PME supply.
Enelion LUMINA now includes a safety monitoring system to detect potential earth-neutral faults. If faults are detected in the circuit, the charge cycle ends thus isolating the vehicle from the power supply.
This removes the risk of touching the vehicle and a potential shock if earth- neutral fault is present.

Daily use and operation

01

How do I charge?

Before using the Enelion LUMINA charger, ensure that the following requirements are met:
· An authorized electrician has made the electrical connection correctly.
· The charger is correctly configured. · The software is up to date. · If access control is configured, block it with
a registered RFID tag or disable it in the configuration panel on the Wi-Fi interface.
Before each use of the Enelion LUMINA charger:
1. Check that the charging cable and connector are not damaged or contaminated, e.g. due to foreign objects or water.
2. Connect the charging cable to the Enelion LUMINA charger and to the electric car. The charging process starts and adapts automatically to the electric car and the available power based on its configuration. If the car does not start charging, check that charging is enabled in your car and that the connectors are correctly connected.

35

02 Interface LED

The Enelion LUMINA charging station has an LED interface that provides the user with basic information:

Status

Light type

Availability

Green flashing

Charging (energy transfer in progress)

Blue flashing from inside towards the edge

Charging (no energy Blue flashing transfer)

Warning/minor error (the charger will attempt to return to its previous state)

Yellow flashing

Error

Red flashing

Fatal error

Steady red

Authorization

Light type

User acceptance

Running from left to right in green

User rejection

Running from left to right in red

Authorization pending White dot moving from left to right

The interface provides only basic operational information, detailed information can be read from the configuration panel.
36

03 Maintenance
The manufacturer recommends conducting an inspection of the device once every 12 months for safety and maintenance reasons. The inspection is not mandatory.
The device is designed to operate in temperatures from -30°C to +55°C. The manufacturer does not guarantee the correct operation of the charging station at temperatures outside of the specified range. Chargers damaged by temperatures below -30°C or above +55°C are not covered under the warranty.

04

Cleaning

The correct way to clean the charger is to wipe the casing with a microfibre cloth using a cleaner dedicated to the plastic of the casing. Plastic parts (the socket) should be cleaned with a microfibre cloth using a cleaning agent dedicated to glass. Other cleaning methods (e.g. using a wire brush) may damage the casing.
Damage caused by improper cleaning of the device does not constitute grounds for warranty claims.

Practical details

Standards
Enelion sp. z o.o. hereby declares that this product, the Enelion LUMINA charging station, complies with:
2014/53/EU (RED); 2011/65/EU (RoHS), 2014/30/EU (EMC) ; 2014/35/EU (LVD); UK SI 2016 No. 1101; UK SI 2016 No. 1091; UK SI 2017 No. 1206; UK SI 2012 No. 3032
The following BSI and ETSI standards and technical specifications have been applied:
ETSI EN 300 328 V2.2.2:2020-03; EN 621962:2017-06; EN IEC 61851-1:2019-10; EN IEC 61851-21-2:2021-09; EN 62196-1:2015-05; ETSI EN 301 511 V12.5.1:2017-10 ETSI EN 300 330 V2.1.1:2017-08; ETSI EN 301 489-1 V2.2.3:202007; ETSI EN 301 489-17 V3.2.4:2021-05
The full content of the declaration of conformity is available at: enelion.com
Disposal
This electronic equipment must not be disposed of with household waste. There may be free collection points available in your area where you can hand over your old equipment. Please follow local regulations for proper and environmentally friendly disposal. If your old electronic equipment contains personal data, you are responsible for removing this data before returning the equipment.
Repair The manufacturer allows for the repair of public, publicly accessible charging stations without the need for UDT reapprovals (if the charger’s parameters have not changed).
The manufacturer permits modular repair, i.e., replacing the entire module or device instead of repairing individual components.
37

If your charger requires repair, please contact your distributor. Returns and complaints For product returns and complaints, please contact your distributor or Enelion customer service.
38

Customer service

Download the latest user manuals, useful documents and videos for your product on https://enelion.com/support-lumina/

This document contains information that is subject to change without notice.
© 2024 ENELION 52 Mialki Szlak St , 80-717 Gdansk, Poland
39

Copyright Enelion sp. z o.o. The manual may change as the product develops. All rights reserved. Revision: V 7.3 Number of pages: 40 Released: March 13, 2024
Enelion sp. z o.o. | 52 Mialki Szlak St 80-717 | Gdansk | Poland sales@enelion.com enelion.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals