Crystal Clean 2733 Adjustable Aqueous Mobile Unit User Manual

October 30, 2023
Crystal Clean

Crystal Clean 2733 Adjustable Aqueous Mobile Unit

Product Information

The MODEL 2733 is an Adjustable Aqueous Mobile Unit that can be operated using either electricity or air. It is designed to clean parts using a mineral spirit based solvent, which is an economical and safe system. The use of solvents to clean grease and oil requires proper disposal. The product must be used in compliance with the guidelines provided by local environmental management agencies.

The parts cleaner should be installed on a flat surface that is adequately ventilated. The use of compressed air to dry parts should be avoided as it may cause a high concentration of vapors in the immediate area. Local exhaust ventilation should be used in areas of high vapor concentration. The operator is responsible for determining and maintaining adequate ventilation. The product must be connected to a properly grounded power source.

It is important to follow the instructions provided in the manual to ensure complete safety during product usage. Any failure to read, understand, and follow all of the procedures in the manual may result in personal injury. The product is not intended for outdoor use.

Product Usage Instructions

  1. Read and understand all labels, MSDS, and the instruction manual before use.
  2. Install the parts cleaner on a flat, level surface in an area provided with adequate ventilation.
  3. Avoid repeated or prolonged breathing of vapors.
  4. Do NOT use compressed air to dry parts.
  5. Use local exhaust ventilation in areas of high vapor concentration.
  6. Ensure that the parts cleaner is connected to a properly grounded power source.
  7. Do not allow the parts cleaner to operate unattended.
  8. Wear protective eyewear, gloves, and clothing during operation.
  9. Conduct operation in a manner that prevents splashing or spillage.
  10. Promptly and properly clean up any spills using absorbent material.
  11. Dispose of all soaked materials in accordance with regulatory requirements.
  12. Do NOT leave solution-soaked rags in parts cleaner or in uncovered containers.
  13. Do NOT obstruct the cover, which is designed to close automatically in the event of a fire.
  14. If an extension cord is necessary, use a cord with a current rating equal to or more than that of the equipment. Arrange the cord so that it will not be tripped over or pulled.

INTRODUCTION

GENERAL INSTRUCTIONS

CAUTION
READ AND UNDERSTAND ALL LABELS, MSDS, AND THIS INSTRUCTION MANUAL BEFORE USE.
The Industrial Solvent Parts Cleaner is an economical, safe, and innovative system designed to clean parts, using a mineral spirit based solvent. Solvents, when used to clean grease and oil, must be disposed of properly. Consult your local environmental management agency for additional guidance and other potentially hazardous materials compliance requirements. Install your parts cleaner on a flat, level surface in an area provided with adequate ventilation. Avoid repeated or prolonged breathing of vapors. Do NOT use compressed air to dry parts as this may cause a high concentration of vapors in the immediate area. Local exhaust ventilation should be used in areas of high vapor concentration. Provisions for determining and maintaining adequate ventilation are the responsibility of the operator. Make sure the parts cleaner is connected to a properly grounded power source. Check serial plate for power requirements. Do not allow parts cleaner to operate unattended. Complete safety in use is dependent upon proper use and handling of the parts cleaner in your workplace. It is important that you follow the instructions provided in this manual. If you fail to read, understand, and follow all of the procedures in this manual, you may cause or suffer personal injury.

DO NOT OPERATE ELECTRICAL EQUIPMENT INSIDE OF PARTS CLEANER.

CAUTION

USE ONLY WATER-BASED CLEANING SOLUTIONS DO NOT USE MINERAL SPIRITS
This equipment is designed for use only with Aqueous Based Solutions. Do NOT add any other chemicals to the cleaning agent including, but not limited to, kerosene, fuel oil, gasoline, or chlorinated solutions. The use of any other solutions could potentially cause a hazardous condition.

CAUTION
DO NOT ALLOW HEATER TO OPERATE UNATTENDED FOR LONG PERIODS, SUCH AS EVENINGS OR WEEKENDS.
Avoid contact with eyes or skin. Wear protective eyewear, gloves, and clothing. Operation should be conducted in a manner, which prevents splashing, or spillage. Any spills should be promptly and properly cleaned up. Soak up all spills with absorbent material. Remove and dispose of all soaked material in accordance with regulatory requirements.

  • This unit is NOT intended for outdoor operation.
  • Do NOT leave solution-soaked rags in parts cleaner or in uncovered containers.
  • Do NOT obstruct the cover. It is designed to close automatically in the event of a fire. The safety link and cover closing mechanism must be intact. Do NOT substitute with any other type of cover positioning device. Do NOT leave large objects in the parts cleaner or hang anything on the cover that could prevent the cover from closing in the event of a fire.
  • Do NOT place heavy objects on edges or front of sink. Although this parts cleaner is designed to be stable, uneven weight distribution could cause a hazardous condition.
  • Do NOT contaminate cleaning solutions with gasoline, alcohol or flammable liquids.
  • When cleaning carburetors or other fuel supplying components: remove all gasoline into a proper disposal container before placing the component into the parts cleaner.
  • Do NOT spray aerosols into or around this machine. Install the equipment in an area away from heat, sparks, and open flame. Never put hot parts into the solution.
  • Do NOT use compressed air to dry parts. Be sure parts, especially brake parts, are completely dry prior to reassembly.
  • Turn unit “OFF” and close lid when equipment is not in use. This will reduce evaporation.

IMPORTANT SAFETY INSTRUCTIONS

  1. Read all instructions.
  2. Care must be taken as burns can occur from touching hot parts.
  3. Do not operate equipment with a damaged cord or if the equipment has been dropped or damaged – until it has been examined by a qualified service person.
  4. If an extension cord is necessary, a cord with a current rating equal to or more than that of the equipment should be used. Cords rated for less current than the equipment may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.
  5. Always unplug equipment from electrical outlet when not in use. Never use the cord to pull the plug from the outlet. Grasp plug and pull to disconnect.
  6. To reduce the risk of fire, do NOT operate equipment in the vicinity of open containers of flammable liquids (gasoline).
  7. To reduce the risk of electric shock, do NOT use on wet surfaces or expose to rain.
  8. Use only as described in this manual. Use only manufacturer’s recommended attachments.
  9. ALWAYS WEAR PROPER PPE
  10. Do NOT operate any electrical equipment inside sink or vat.
  11. Do NOT use light bulbs rated over 40 watts.
  12. Do NOT smoke, eat or drink in the work area.
  13. Do NOT modify these machines.
  14. Do NOT operate this unit in any manner that will cause splashing or cause mist to form.
  15. Use only the aqueous solution provided.
  16. Adjust flexible nozzle or flow-thru brush so solution is directed to inside the sink only.
  17. On the Control box, set the breaker switches to OFF before plugging in unit.
  18. In any emergency, turn off the unit.
  19. These parts washers employ a safety feature called a fusible link that holds the cover open during use. Do NOT modify, alter, or obstruct the operation of the fusible link.
  20. Keep cover closed whenever unit is not in use.
  21. Do NOT remove fluid from this equipment or it may cause malfunction or unsafe conditions.

SAVE THESE INSTRUCTIONS

SERVICE

  • Call your representative should your parts cleaner need service and always unplug unit when servicing.
  • Inspect and keep in good working order the power cord and all electrical components. If components show signs of damage or wear replace immediately. All work should be done by a trained technician.
  • Do NOT replace pump before unplugging unit.
  • Do NOT replace fusible link with any other device to hold lid up. If fusible link should fail, for any reason, call your representative immediately.

INSTALLATION

  • Install the parts cleaner on a flat, level surface in a well-ventilated area.
  • Remove the parts packed inside the machine and inspect for damage.
  • Fill the machine with 5 gallons of aqueous based solvents. Do NOT add any other chemicals to the cleaning agent including, but not limited to, kerosene, fuel oil, gasoline, or chlorinated solutions. The use of any other solutions could potentially cause a hazardous condition.
  • Plug the power cord into a properly grounded power source. See serial number plate for proper voltage.
    • Power Requirements = 1 amp, 115 volt 60 Hz OR
    • Power Requirements = 80PSI (Air Operated)
  • Weight capacity for this parts cleaner is 50 LBS
  • Turn on switch to start flow of chemistry, using the brush to scrub parts.
  • When not in use, close cover to reduce chemistry loss.

ADDITIONAL SPECIFICATIONS

  • Overall Dimensions: 28.5″L x 14″W x 22″H (lid up)
  • Inside Dimensions: 25″L x 14″W x 9″H
  • Shipping Weight: 52lbs.
  • 115Vac/60HZ/1PH
  • 1 Amp

MACHINE DIAGRAM

Parts Breakdown – Electric Pump

Parts Breakdown – aIR Pump

TROUBLESHOOTING

Machine does not operate:

  • Make sure the parts cleaner is connected to electric power or air supply.
  • Check for incoming power. Check serial plate for power requirements.
  • On electric units: check reset button on GFCI cord to make sure it is not tripped. On air units: an increase in air supply may be required.

Little or no fluid flow thru the flow-thru brush:

  • Turn pump switch “ON” or increase air pressure.
  • Check the fluid level in the tank.
  • Check pump intake for obstructions.

Heritage-Crystal Clean,
LLC 2000 Center Drive,
Suite East C300 Hoffman Estates,
IL 60192 877-938-7948

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals