INTRODUCTION
GENERAL INSTRUCTIONS
CAUTION
READ AND UNDERSTAND ALL LABELS, MSDS, AND THIS INSTRUCTION MANUAL BEFORE
USE.
The Industrial Solvent Parts Cleaner is an economical, safe, and innovative
system designed to clean parts, using a mineral spirit based solvent.
Solvents, when used to clean grease and oil, must be disposed of properly.
Consult your local environmental management agency for additional guidance and
other potentially hazardous materials compliance requirements.
Install your parts cleaner on a flat, level surface in an area provided with
adequate ventilation. Avoid repeated or prolonged breathing of vapors. Do NOT
use compressed air to dry parts as this may cause a high concentration of
vapors in the immediate area. Local exhaust ventilation should be used in
areas of high vapor concentration. Provisions for determining and maintaining
adequate ventilation are the responsibility of the operator.
Make sure the parts cleaner is connected to a properly grounded power source.
Check serial plate for power requirements.
Do not allow parts cleaner to operate unattended.
Complete safety in use is dependent upon proper use and handling of the parts
cleaner in your workplace.
It is important that you follow the instructions provided in this manual. If
you fail to read, understand, and follow all of the procedures in this manual,
you may cause or suffer personal injury.;
DO NOT OPERATE ELECTRICAL EQUIPMENT INSIDE OF PARTS CLEANER.
**CAUTION**
USE ONLY MINERAL SPIRITS BASED SOLVENTS DO NOT USE WATER-BASED CLEANING
SOLUTIONS
This equipment is designed for use only with mineral spirit based solvents
with a flash point greater than 40°C (104°F).
Do NOT add any other chemicals to the cleaning agent including, but not
limited to, kerosene, fuel oil, gasoline, or chlorinated solutions. The use of
any other solutions could potentially cause a hazardous condition.
Avoid contact with eyes or skin. Wear protective eyewear, gloves, and
clothing. Operation should be conducted in a manner, which prevents splashing,
or spillage. Any spills should be promptly and properly cleaned up. Soak up
all spills with absorbent material. Remove and dispose of all soaked material
in accordance with regulatory requirements.
- This unit is NOT intended for outdoor operation.
- Do NOT leave solution-soaked rags in parts cleaner or in uncovered containers.
- Do NOT obstruct the cover. It is designed to close automatically in the event of a fire. The safety link and cover closing mechanism must be intact. Do NOT substitute with any other type of cover positioning device. Do NOT leave large objects in the parts cleaner or hang anything on the cover that could prevent the cover from closing in the event of a fire.
- Do NOT place heavy objects on edges or front of sink. Although this parts cleaner is designed to be stable, uneven weight distribution could cause a hazardous condition.
- Do NOT contaminate cleaning solutions with gasoline, alcohol or flammable liquids.
- When cleaning carburetors or other fuel supplying components: remove all gasoline into a proper disposal container before placing the component into the parts cleaner.
- Do NOT spray aerosols into or around this machine. Install the equipment in an area away from heat, sparks, and open flame. Never put hot parts into the solution.
- Do NOT use compressed air to dry parts. Be sure parts, especially brake parts, are completely dry prior to reassembly.
- Turn unit “OFF” and close lid when equipment is not in use. This will reduce evaporation.
IMPORTANT SAFETY INSTRUCTIONS
- Read all instructions.
- Do not operate equipment with a damaged cord or if the equipment has been dropped or damaged – until it has been examined by a qualified service person.
- If an extension cord is necessary, a cord with a current rating equal to or more than that of the equipment should be used. Cords rated for less current than the equipment may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled.
- Always unplug equipment from electrical outlet when not in use. Never use the cord to pull the plug from the outlet. Grasp plug and pull to disconnect.
- To reduce the risk of fire, do NOT operate equipment in the vicinity of open containers of flammable liquids (gasoline).
- To reduce the risk of electric shock, do NOT use on wet surfaces or expose to rain.
- Use only as described in this manual. Use only manufacturer’s recommended attachments.
- ALWAYS WEAR PROPER PPE
- Do NOT operate any electrical equipment inside sink or vat.
- Do NOT use light bulbs rated over 40 watts.
- Do NOT smoke, eat or drink in the work area.
- Do NOT modify these machines.
- Do NOT operate this unit in any manner that will cause splashing or cause mist to form.
- Use only the aqueous solution provided.
- Adjust flexible nozzle or flow-thru brush so solution is directed to inside the sink only.
- On the Control box, set the breaker switches to OFF before plugging in unit.
- In any emergency, turn off the unit.
- These parts washers employ a safety feature called a fusible link that holds the cover open during use. Do NOT modify, alter, or obstruct the operation of the fusible link.
- Keep cover closed whenever unit is not in use.
- Do NOT remove fluid from this equipment or it may cause malfunction or unsafe conditions.
SAVE THESE INSTRUCTIONS
SERVICE
- Call your representative should your parts cleaner need service and always unplug unit when servicing’s
- Inspect and keep in good working order the power cord and all electrical components. If components show signs of damage or wear replace immediately. All work should be done by a trained technician.
- Do NOT replace pump before unplugging unit.
- Do NOT replace fusible link with any other device to hold lid up. If fusible link should fail, for any reason, call your representative immediately.
INSTALLATION
- Install the parts cleaner on a flat, level surface in a well-ventilated area.
- Remove the parts packed inside the machine and inspect for damage.
- Attach machine to filled 16 gallon drum of a mineral spirit based solvents. Do NOT add any other chemicals to the cleaning agent including, but not limited to, kerosene, fuel oil, gasoline, or chlorinated solutions. The use of any other solutions could potentially cause a hazardous condition.
- Plug the power cord into a properly grounded power source. See serial number plate for proper voltage.
Power Requirements = 60 PSI, 77 CFM
- Weight capacity for this parts cleaner is 20 LBS
ADDITIONAL SPECIFICATIONS
- Overall Dimensions: 16″W x 31″H
- Basket Dimensions: 11.5″ Diameter x 7.5”D
- Shipping Weight: 50lbs.
- Air Operated 60 PSI, 77 CFM
MACHINE DIAGRAM
ITEM | QTY | PART NO | DESCRIPTION |
---|---|---|---|
1 | 1 | 57586 | COVER |
2 | 1 | 57576 | VALVE ASSEMBLY |
3 | 1 | 6470 | TIMER |
4 | 1 | 50347 | LID |
5 | 1 | 7544 | MOTOR KIT |
6 | 1 | 57592 | HOOK WELD |
7 | 1 | 57575 | RING |
8 | 1 | 2387 | HINGE ROD |
9 | 1 | 57594 | BASKET |
TROUBLESHOOTING
Machine does not operate:
- Make sure the parts cleaner is connected to electric power or air supply.
- Check for incoming power. Check serial plate for power requirements.
- On electric units: check reset button on GFCI cord to make sure it is not tripped. On air units: an increase in air supply may be required
Little or no fluid flow thru the flow-thru brush:
- Turn pump switch “ON” or increase air pressure.
- Check the fluid level in the tank.
- Check pump intake for obstructions.
Heritage-Crystal Clean, LLC 2000 Center Drive,