MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan Instruction Manual
- October 30, 2023
- MONTE CARLO
Table of Contents
5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
Instruction Manual
Attach sales receipt to this card and retain as your proof of purchase
DATE OF PURCHASE: —————————————
MODEL NUMBER: ——————————————-
RETAILER NAME: ——————————————-
RETAILER ADDRESS: —————————————
To register your fixture, please visit our website
www.montecarlofans.com
8.3 kg
18.3 lbs
Total fan weight with light
Cautions and Warnings
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS
Installation work and electrical wiring must be done by qualified person(s) in
accordance with applicable codes and standards (ANSI/NFPA 70) including fire-
rated construction.
Use this unit only in the manner intended by the manufacturer. If you have any
questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the
grounded conductor and the equipment-grounding conductor on one side of the
outlet box and ungrounded conductor on the other side of the outlet box. The
splices, after being made, should be turned upward and pushed carefully up
into the outlet box.
WARNING: Before you begin installing the fan, servicing or cleaning unit,
Switch power off at Service panel and lock service disconnecting means to
prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing
your new fan. Review the accompanying assembly diagrams. When cutting or
drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate
without any obstructions. Allow a minimum clearance of 7 feet from the floor to
the trailing edge of the blade.
WARNING: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury,
Mount To Outlet Box Marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or
less” And Use Mounting Screws Provided With The Outlet Box.
CAUTION: For Compliance with Local Codes and Regulations, If Installing
The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts In The
Outlet Box. Mount the secondary support safety cable through the reserved
nail/screw hole on the outlet box to the building structure (or the ceiling
joist).
WARNING: To reduce the risk of personal injury, do not bend blade holders
during installation to motor, balancing or during cleaning. Do not insert
foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet
box.
WARNING: To reduce the risk of fire or electric shock, do not use this fan
with any unverified solid state fan speed control device, or variable speed
control.
If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may
be affected by this unit’s operation. Follow the heating equipment
manufacturer’s guideline safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local
code authorities.
CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical
supply circuit to the fan before installing the light kit. All set screws must
be checked and tightened where necessary before installation.
Note: Suitable for use in wet locations when installed in a GFCI
protected branch circuit.
Tools Required for Assembly (not included): Electrical Tape, Phillips
Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers
Customer Service
800-969-3347
Customer Service Center
7400 Linder Ave.
Skokie, IL 60077
www.montecarlofans.com
Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. Use AC 120V/60HZ power supply only.
Before installing this fan make sure the outlet box is properly installed to
the house structure. To reduce the risk of fire, electric shock, or personal
injury, mount to outlet box or supporting system acceptable for fan support.
(Mounting must support at least 35 lbs.)
Use metal outlet box suitable for fan support and use only the screws provided with the outlet box (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member ( a loose box will cause the fan to wobble).
Install the mounting bracket onto the outlet box.
Partially loosen the two screws on the outlet box, attach the mounting bracket
onto the outlet box by sliding it over the two screws as shown in the
illustration. Have the mounting bracket in position and tighten the set
screws.
Downrod Mount Installation
Partially loosen downrod set screws from yoke at top of motor assembly.
Remove preassembled cross pin and keeper pin from downrod.
Place downrod over canopy, canopy bottom ring and yoke cover. Thread lead
wires and safety cable from motor assembly through downrod.
Slip downrod into motor housing yoke, aligning holes and install cross pin and
keeper pin.
Insert cross pin through yoke and downrod until point appears on the other
side, and insert keeper pin on cross pin.
Pull the downrod up tight against the cross pin, and then evenly tighten the
downrod set screws on motor housing yoke.
Place yoke cover on top housing of fan.
Warning: Cross pin and keeper pin must be installed securely, failure to
install them will result in serious injury.
![MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
- downrod into mounting](https://manuals.plus/wp-content/uploads/2023/06 /MONTE-CARLO-5LDO52RZWD-Linden-52-Inch-Indoor-Outdoor-Matte-White-Ceiling-Fan- downrod-into-mounting.png)
Install ball end of downrod into mounting bracket opening. Align (engage) slot
on ball with tab on mounting bracket.
Warning: Failure to align slot on ball with tab may result in serious
injury.
Important: If using the angle mount, make sure open end of mounting
bracket is installed facing the higher point of the ceiling and make sure the
ceiling angle is not steeper than 20º.
SAFETY CABLE INSTALLATION
![MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
- SAFETY CABLE INSTALLATION](https://manuals.plus/wp-content/uploads/2023/06 /MONTE-CARLO-5LDO52RZWD-Linden-52-Inch-Indoor-Outdoor-Matte-White-Ceiling-Fan- SAFETY-CABLE-INSTALLATION.png)
Safety cable must be installed into the house structure using 3” lag screws,
washers, and lock washers provided, required for outdoor applications and in
Canada (All fans installed in Canada), and for USA fan and light kit
combinations over 35lbs.
Make sure that when the safety cable is fully extended, the lead wires are
longer than the cable and no stress is placed on the lead wires.
Note: If installing the secondary support safety cable in the U.S., do
not remove knockouts in the outlet box.
![MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
- wiring connections](https://manuals.plus/wp-content/uploads/2023/06/MONTE- CARLO-5LDO52RZWD-Linden-52-Inch-Indoor-Outdoor-Matte-White-Ceiling-Fan-wiring- connections.png)
Make wiring connections using wire connectors provided as indicated above. White from fan to White (Neutral) from house. Black and Blue from fan to Black (Live) from house. Connect all green grounded wires to Grounded wire from House. Make sure that no filaments are outside of the wire connectors.
![MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
- spread apart](https://manuals.plus/wp-content/uploads/2023/06/MONTE-CARLO- 5LDO52RZWD-Linden-52-Inch-Indoor-Outdoor-Matte-White-Ceiling-Fan-spread- apart.png)
After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices after being made should be turned upward and pushed carefully up into the outlet box.
![MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
- Lift Canopy](https://manuals.plus/wp-content/uploads/2023/06/MONTE-CARLO- 5LDO52RZWD-Linden-52-Inch-Indoor-Outdoor-Matte-White-Ceiling-Fan-Lift- Canopy.png)
Lift Canopy allowing the 2 studs to protrude through the canopy.
Next lift the cover ring and install knurled nuts as shown. Tighten the
knurled nuts securely. The canopy should adjust for any irregularity in the
ceiling or Outlet box.
Make sure the studs protruding from the bottom of the Mounting bracket are
installed with threads all the way through the bracket.
Flush Mount Installation
![MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
- screws](https://manuals.plus/wp-content/uploads/2023/06/MONTE-CARLO- 5LDO52RZWD-Linden-52-Inch-Indoor-Outdoor-Matte-White-Ceiling-Fan-screws.png)
Remove every other screws from yoke located on top of fan assembly. Keep
screws.
Note: Flush mount is not available with vaulted ceiling.
![MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
- Remove side covers](https://manuals.plus/wp-content/uploads/2023/06/MONTE- CARLO-5LDO52RZWD-Linden-52-Inch-Indoor-Outdoor-Matte-White-Ceiling-Fan-Remove- side-covers.png)
Remove side covers from canopy exposing 4 holes. 2 closed holes and 2 open “L”
shape holes.
Place rubber pad and canopy over lead wire and safety cable and align the
larger holes in canopy and holes on rubber pad with the set screws on yoke.
![MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
- Tighten screws](https://manuals.plus/wp-content/uploads/2023/06/MONTE-CARLO- 5LDO52RZWD-Linden-52-Inch-Indoor-Outdoor-Matte-White-Ceiling-Fan-Tighten- screws.png)
Reinstall the 3 set screws remove in step 12. Tighten screws securely.
![MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
- hang fan](https://manuals.plus/wp-content/uploads/2023/06/MONTE-CARLO- 5LDO52RZWD-Linden-52-Inch-Indoor-Outdoor-Matte-White-Ceiling-Fan-hang-fan.png)
To prepare the fan for wiring, hang fan onto mounting bracket by sliding the
canopy over the mounting bracket hook (Use one of non-slotted holes on the
rim of the canopy).
![MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
- light kit combinations](https://manuals.plus/wp-content/uploads/2023/06
/MONTE-CARLO-5LDO52RZWD-Linden-52-Inch-Indoor-Outdoor-Matte-White-Ceiling-Fan-
light-kit-combinations.png)For Canadian installation and for USA fan and light
kit combinations over 35 lbs, in both flush and downrod modes the safety cable
must be installed into the house structure beams using 3” lag screws, washers
and lock washers provided. Make sure that when the safety cable is fully
extended the lead wires are longer than the cable and no stress is placed on
the lead wires.
Note: If Installing The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts In The Outlet Box.
![MONTE CARLO 5LDO52RZWD Linden 52 Inch Indoor Outdoor Matte White Ceiling Fan
- wiring connections](https://manuals.plus/wp-content/uploads/2023/06/MONTE- CARLO-5LDO52RZWD-Linden-52-Inch-Indoor-Outdoor-Matte-White-Ceiling-Fan-wiring- connections-1.png)
Make wiring connections using wire connectors provided as indicated above.
White from fan to White (Neutral) from house. Black and Blue from fan to Black
(Live) from house. Connect all green grounded wires to Grounded wire from
House. Make sure that no filaments are outside of the wire connectors.
After making the wire connections, the wires should be spread apart with the
grounded conductor and the equipment-grounding conductor on one side of the
outlet box and ungrounded conductor on the other side of the outlet box. The
splices after being made should be turned upward and pushed carefully up into
the outlet box.
Install 2 of the screws to the side panel of mounting bracket corresponding to
the open slotted holes on the canopy upper rim, screws provided. Remove the
thread studs from the lower part of the mounting bracket.
Lift fan to mounting bracket, aligning the “L” shape holes on canopy with the
screws on the mounting bracket. Turn the fan clockwise to lock in position.
Install the other 2 canopy mounting set screws from the hardware pack and
tighten all screws securely.
Install blade bracket with blade by 3 blade screws and washers provided.
Tighten screws securely. Repeat this process for remaining blades.
Note: Make sure the side with a mark “This side up” is installed upward.
Remove shipping stabilizers from motor assembly.
Install the blade assembly to motor using the preinstalled screws. Tighten
screws securely. Repeat this process for remaining blade assemblies.
Remove the set screws from switch housing cap on top of light fixture. Keep
screws.
Connect light lead wires. White to white, blue (or black) to black (or blue).
Make sure the quick connectors are clasped firmly.
Align the pull chains from fan with the pull chain guides on light fixture and
then attach light fixture onto the switch housing of fan, aligning the holes
and reinstall the set screws.
Remove finial, final cap, hex nut and rubber washer from light fixture. Keep the parts.
Install 2 x 9W medium base dimmable LED bulbs. California Title 24 compliant
bulbs included.
Caution: Approved for use with LED light bulb only (Part No. 97512S).
Do not use incandescent light bulb.
Caution: Do not replace bulb until it cools down.
Raise glass in order to guide pull chains through appropriate holes in glass,
aligning threaded rod on light fixture with hole in middle of the glass and
push up gently allowing threaded rod to come through hole.
( Note: Be sure pull chain for fan operation does not rub against bulb
during operation).
Install the rubber washer and hex nut to hold the glass. DO NOT OVER TIGHTEN
IT.
Align hole in center of final cap with thread rod, allowing pull chains to come through appropriate holes in the final cap, and push up. Thread center pull chain through hole in finial and secure glass to light fixture by tightening the finial. DO NOT OVER TIGHTEN the finial as glass may crack or break.
Setting the reverse switch in the down position will result in downward airflow
and setting the switch in the up position will result in upward airflow.
Note: Reverse switch must be set either completely down or completely up
for fan to function. If the reverse switch is set in the middle position, fan
will not operate.
Thread pull chains through pull chain guides, and Install pull chains to preassembled pull chains on fan. Pull chains provided.
Troubleshooting
If you have difficulty operating your new ceiling fan, it may be the result of
incorrect assembly, installation, or wiring. In some cases, these installation
errors may be mistaken for defects. If you experience any faults, please check
this Troubleshooting Chart. If a problem cannot be remedied, or you are
experiencing difficulty in installation, please call our Customer Service
Center at the number printed on your parts list insert sheet.
Warning: Before you begin installing, servicing or cleaning the fan unit,
switch the power off at the service panel and lock the service panel to
prevent the power from being switched back on accidentally. If the service
panel cannot be locked to prevent the power from being switched on
accidentally, securely fasten a warning sign to the service panel.
Trouble | Suggested Remedy |
---|---|
1. If fan does not start: | 1. Check main and branch circuit fuses or circuit |
breakers.
2. Check line wire connections to fan and switch wire connections in switch
housing.
CAUTION: Make sure main power is turned off.
3. If this fan uses manual forward/reverse switch, make sure the switch is
pushed firmly either way. Fan will not operate when switch is in the middle.
4. If this fan uses a remote controller, make sure dip switches are in the
correct setting and make sure the battery works.
2. If fan sounds noisy:| 1. Check to make sure all screws in motor housing
are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade holder to the
motor are tight.
3. Check to make sure wire nut connectors in switch housing are not rattling
against each other or against the interior wall of the switch housing.
CAUTION: Make sure main power is turned off before entering switch
housing.
4. Check to be sure lightbulb is tight in socket and not touching the glass
shade.
5. Some fan motors are sensitive to signals from Solid State variable speed
controls.
6. Allow “break-in” period of 24 hours. Most noises associated with a new fan
will disappear after this period.
3. If fan wobbles:| 1. If this is a downrod mount fan, make sure the ridge
on mounting bracket engages the notch in the downrod ball.
2. Make sure that canopy, mounting bracket or mounting plate are tightened
securely to ceiling junction box and junction box is mounted firmly to ceiling
joist.
3. Check that all blades are screwed firmly into blade holders.
4. Check that all blade holders are tightened securely to motor.
5. Most fan wobble problems are caused when blade levels are unequal. Check
this level by selecting a point on the ceiling above the tip of one of the
blades. Measure this distance from blade tip to ceiling. Keeping measure
within 1/8″, rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. If all blade levels are not equal, you can
adjust blade levels by the following procedure. To adjust a blade tip down,
insert a washer (not supplied) between the blade and blade holder at the screw
closest to the motor. To adjust a blade tip up, insert washer (not supplied)
between the blade and blade holder at the two screws farthest from the motor.
Reverse the position of the washer if blades mount from top of blade.
6. If blade wobble is still noticeable, interchanging two adjacent blades can
redistribute the weight and possibly result in smoother operation. If the
above steps do not eliminate the wobble problem, you will need to dynamically
balance your fan with balancing kit provided.
4. If light does not work:| 1. Check blue wire from fan to make sure it is
connected to hot wire from house.
2. Check for loose or disconnected wires in fan switch housing.
3. Check for loose or disconnected wires in light kit.
4. Check for faulty lightbulb and make sure bulb is tight in socket.
5. Remove light kit and check the plug connections if they are present.
6. If this fan uses a remote controller, make sure dip switches are in the
correct setting and make sure the battery works.
CAUTION: Make sure main power is turned off before entering switch
housing and/or canopy.
© 2022 Monte Carlo Fan Collections
Mar.2022