Cautions and Warnings
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS
Installation work and electrical wiring must be done by qualified person(s) in
accordance with applicable codes and standards (ANSI/NFPA 70), including fire-
rated construction.
Use this unit only in the manner intended by the manufacturer. If you have any
questions contact the manufacturer.
After making the wire connections, the wires should be spread apart with the
grounded conductor and the equipment-grounding conductor on one side of the
outlet box and ungrounded conductor on the other side of the outlet box. The
splices, after being made, should be turned upward and pushed carefully up
into the outlet box.
WARNING: Before you begin installing the fan, servicing or cleaning unit,
Switch power off at Service panel and lock service disconnecting means to
prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
Be cautious! Read all instructions and safety information before installing
your new fan. Review the accompanying assembly diagrams.
When cutting or drilling into wall or ceiling, do not damage electrical wiring
and other hidden utilities.
Make sure the installation site you choose allows the fan blades to rotate
without any obstructions. Allow a minimum clearance of 7 feet from the floor to
the trailing edge of the blade.
WARNING: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury,
Mount To Outlet Box Marked “Acceptable for Fan Support of 15.9 kg (35 lbs) or
less” And Use Mounting Screws Provided With The Outlet Box.
CAUTION: For Compliance with Local Codes and Regulations, If Installing
The Secondary Support Safety Cable in the U.S., Do Not Remove Knockouts In The
Outlet Box. Mount the secondary support safety cable through the reserved
nail/screw hole on the outlet box to the building structure (or the ceiling
joist).
WARNING: To reduce the risk of personal injury, do not bend blade holders
during installation to motor, balancing or during cleaning. Do not insert
foreign object between rotating blades.
Attach the mounting bracket using only the hardware supplied with the outlet
box.
WARNING: To reduce the risk of fire or electric shock, this fan should
only be used with fan speed control part no. UC9020 manufactured by Rhine
Electronic Co., Ltd.
WARNING: To reduce the risk of fire or electric shock, do not use this fan
with any other solid state fan speed control device, or variable speed
control.
If this unit is to be installed over a tub or shower, it must be marked as
appropriate for the application.
Never place a switch where it can be reached from a tub or shower.
The combustion airflow needed for safe operation of fuel-burning equipment may
be affected by this unit’s operation. Follow the heating equipment
manufacturer’s guideline safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local
code authorities.
CAUTION: To Reduce the Risk of Electric Shock, Disconnect the electrical
supply circuit to the fan before installing the light kit.
CAUTION: The light source is designed for this specific application and
can overheat if serviced by untrained personnel. If any servicing is required,
the product should be returned to an authorized service facility for
examination or repair.
All set screws must be checked and tightened where necessary before
installation.
Note: Suitable for use in damp locations. Install the fan under covered
or enclosed patios or porches.
Tools Required for Assembly (not included): Electrical Tape, Phillips
Screwdriver, Pliers, Safety Glasses, Stepladder and Wire Strippers Before you
begin installing the fan, Switch power off at Service panel and lock service
disconnecting means to prevent power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely fasten a warning
device, such as a tag, to the service panel.
Use AC 120V/60HZ power supply only. Before installing this fan make sure the
outlet box is properly installed to the house structure. To reduce the risk of
fire, electric shock, or personal injury, mount to outlet box or supporting
system acceptable for fan support.
(Mounting must support at least 35 lbs.) Use metal outlet box suitable for fan
support and use only the screws provided with the outlet box (must support 35
lbs). Before attaching fan to outlet box, ensure the outlet box is securely
fastened by at least two points to a structural ceiling member ( a loose box
will cause the fan to wobble). Remove the two outlet box screws provided with
the box, aligning the holes of the mounting bracket with the holes of the
outlet box. Reinstall the 2 outlet box screws securely. Install a blade
bracket onto blade with a blade bottom plate using set screws provided. Repeat
this process for remaining blades. Put motor assembly on a suitable area of
paper pulp.
Remove the blade set screws from motor.
Install the blade assembly to motor using the set screws. Tighten screws
securely. Repeat this process for remaining blade assemblies. Partially loosen
downrod set screws from yoke at top of motor assembly.
Remove preassembled cross pin and keeper pin from downrod. Keep parts.
Place downrod over canopy, canopy bottom cap and yoke cover. Thread lead wires
and safety cable from motor assembly through downrod. Slip downrod into motor
housing yoke, aligning holes and install cross pin and keeper pin.
Insert cross pin through yoke and downrod until point appears on the other
side, and insert keeper pin on cross pin.
Pull the downrod up tight against the cross pin, and then evenly tighten the
downrod set screws on motor housing yoke.
Place yoke cover on top housing of fan.
Warning: Cross pin and keeper pin must be installed securely, failure to
install them will result in serious injury. Install ball end of downrod into
mounting bracket opening. Align (engage) slot on ball with tab on mounting
bracket.
Warning: Failure to align slot on ball with tab may result in serious injury.
Important: If using the angle mount, make sure open end of mounting bracket is
installed facing the higher point of the ceiling and make sure the ceiling
angle is not steeper than 20º. Longer downrod may be necessary allowing the
fan blades to rotate without obstructions. Safety cable must be installed into
the house structure using 3” lag screws, washers, and lock washers provided,
required for outdoor applications and in Canada (All fans installed in
Canada), and for USA fan and light kit combinations over 35lbs.
Make sure that when the safety cable is fully extended the lead wires are
longer than the cable and no stress is placed on the lead wires.
Note: If Installing The Secondary Support Safety Cable in the U.S., Do
Not Remove Knockouts In The Outlet Box. Refer to page 6 for wiring,
installation and operation of Wall controller. Do not operate the fan or light
until it is installed completely After making the wire connections, the wires
should be spread apart with the grounded conductor and the equipment-grounding
conductor on one side of the outlet box and ungrounded conductor on the other
side of the outlet box. The splices after being made should be turned upward
and pushed carefully up into the outlet box. Partially loosen one and remove
one preassembled screw from mounting bracket. Save screw.
Lift canopy up, aligning its keyhole slot with the preassembled screw on
mounting bracket and twist clockwise to lock in place. Reinstall the screw
removed and tighten all screws securely. Attach canopy bottom cap onto canopy
by aligning its holes with the screws on mounting bracket and fix it with the
magnet which is embedded in the cap. Setting the reverse switch in the down
position will result in downward airflow and setting the switch in the up
position will result in upward airflow.
Note: Reverse switch must be set either completely down or completely up
for fan to function. If the reverse switch is set in the middle position, fan
will not operate. Warning: Before proceeding, be sure to shut off
electricity at main switch or circuit breaker in order to avoid electrical
shock.
Note: Before installing the wall transmitter, place it in OFF position.
(Fig.2)
Make series-wound connection for the wall controller with HOT wire from house
and lead wires from fan.
Connect the black wire marked “AC IN L” from wall controller to the HOT wire
from house and then connect the black wire marked “TO MOTOR L” of wall
controller to the fan lead wire from fan in outlet box.
Connect green/yellow grounded wire to grounded wire from outlet box.
Install the wall controller to outlet box using machine screws provided.
Attach wall plate to wall control unit with screws provided. (Fig.1)
Operation
This wall controller provides 4 fan speeds.(Fig.2)
1 – High – , 2 – Medium high , 3 –
Medium , 4 – Low , – Off.
Troubleshooting
If you have difficulty operating your new ceiling fan, it may be the result of
incorrect assembly, installation, or wiring. In some cases, these installation
errors may be mistaken for defects. If you experience any faults, please check
this Troubleshooting Chart. If a problem cannot be remedied, or you are
experiencing difficulty in installation, please call our Customer Service
Center at the number printed on your parts list insert sheet.
Warning: Before you begin installing, servicing or cleaning the fan unit,
switch the power off at the service panel and lock the service panel to
prevent the power from being switched back on accidentally. If the service
panel cannot be locked to prevent the power from being switched on
accidentally, securely fasten a warning sign to the service panel.
Trouble | Suggested Remedy |
---|---|
1. If fan does not start: | 1. Check main and branch circuit fuses or circuit |
breakers.
2. Check line wire connections to fan and switch wire connections in switch
housing.
CAUTION: Make sure main power is turned off.
3. if this fan uses manual forward/reverse switch, make sure the switch is
pushed firmly either way. Fan will not operate when switch is in the middle.
4. If this fan uses a remote controller, make sure dip switches are in the
correct setting and make sure the battery works.
2. If fan sounds noisy:| 1. Check to make sure all screws in motor housing
are snug (not over tightened).
2. Check to make sure the screws which attach the fan blade holder to the
motor are tight.
3. Check to make sure wire nut connectors in switch housing are not rattling
against each other or against the interior wall of the switch housing.
CAUTION: Make sure main power is turned off before entering switch housing.
4. Check to be sure light bulb is tight in socket and not touching the glass
shade.
5. Some fan motors are sensitive to signals from Solid State variable speed
controls.
6. Allow “break-in” period of 24 hours. Most noises associated with a new fan
will disappear after this period.
3. If fan wobbles:| 1. if this is a downrod mount fan, make sure the ridge
on mounting bracket engages the notch in the downrod ball.
2. Make sure that canopy, mounting bracket or mounting plate are tightened
securely to ceiling junction box and junction box is mounted firmly to ceiling
joist.
3. Check that all blades are screwed firmly into blade holders.
4. Check that all blade holders are tightened securely to motor.
5. Most fan wobble problems are caused when blade levels are unequal. Check
this level by selecting a point on the ceiling above the tip of one of the
blades. Measure this distance from blade tip to ceiling. Keeping measure
within 1/8″, rotate the fan until the next blade is positioned for
measurement. Repeat for each blade. if all blade levels are not equal, you can
adjust blade levels by the following procedure. To adjust a blade tip down,
insert a washer (not supplied) between the blade and blade holder at the screw
closest to the motor. To adjust a blade tip up, insert washer (not supplied)
between the blade and blade holder at the two screws farthest from the motor.
Reverse the position of the washer if blades mount from top of blade.
6. If blade wobble is still noticeable, interchanging two adjacent blades can
redistribute the weight and possibly result in smoother operation. If the
above steps do not eliminate the wobble problem, you will need to dynamically
balance your fan with balancing kit provided.
4. If light does not work:| 1. Check blue wire from fan to make sure it is
connected to hot wire from house.
2. Check for loose or disconnected wires in fan switch housing.
3. Check for loose or disconnected wires in light kit.
4. Check for faulty lightbulb and make sure bulb is tight in socket.
5. Remove light kit and check the plug connections if they are present.
6. If this fan uses a remote controller, make sure dip switches are in the
correct setting and make sure the battery works.
CAUTION: Make sure main power is turned off before entering switch
housing and/or canopy.
© 2022 Monte Carlo Fan Collections
Jan.2022