1400LB / 600KG
Dear user:
Thank you for choosing our product. Please read this manual carefully before
assembly and use. Please do not forget to include this manual if you send this
product to a third party.
SAFETY NOTICE
Please ensure that your power voltage matches with the supply voltage for the
gate opener (110V AC) before installation.
The installation and maintenance of this product and its components must be
carried out by trained profes- sionals to ensure safety and safe use.
Please ensure that children do not use or play with the built-in or remote
control devices.
Please ensure that no one is around the main engine or gate when the switch is
operated.
Cease use temporarily when the main engine needs repairing or regulating. If
needed, the main engine and gate can be unlocked with a disengagement wrench.
The gate can be moved manually after disengagement.
PACKING LIST (STANDARD)
No. | Picture | Name | Quantity |
---|---|---|---|
1 | Main engine | 1 | |
2 | Manual release key | 2 | |
3 | Remote control | 2 | |
4 | Mounting accessories box | 1 | |
4-1 | Sprocket cover | 1 | |
4-2 | Chain link | 2 | |
4-3 | 20 ft. (6 m) Chain | 1 | |
4-4 | Tie rod | 2 | |
4-5 | Square bolt | 4 | |
4-6 | Door connecting plate | 2 | |
4-7 | ![DOORADO SGO-EC08-00-BNHD-1 Smart Slide Single Automatic Gate Opener Kit |
- Picture 11](https://manuals.plus/wp-content/uploads/2023/06/DOORADO-SGO-
EC08-00-BNHD-1-Smart-Slide-Single-Automatic-Gate-Opener-Kit-Picture-11.png)|
Horizontal mounting plate| 1
4-8| | Vertical mounting plate| 2
4-9| | M8 foundation bolt| 4
4-10| | Magnets & blocks| 4
4-11| | Inner M6 20 mm bolt| 4
4-12| | M6 65 mm bolt| 4
M8 25 mm bolt| 4
4-13| | M6 nut| 16
M8 nut| 16
4-14| | φ6 flat washer| 16
φ8 flat washer| 16
4-15| | φ6 spring washer| 16
φ8 spring washer| 12
TECHNICAL PARAMETERS
Maximum weight of gate | 1400 lb (600 kg) |
---|---|
Power supply | 110V/60Hz |
Motor power | 180W |
Gate moving speed | 39.36 ft./min. |
Remote control distance | ≥98.4ft. (30 m) |
Remote control mode | Single button mode |
Limit switch | Magnetic limit switch |
Noise | ≤58 dB |
Working duty | S2, 15min |
Recording of up remote controls | 25 |
Frequency | 433.92 MHz |
Working temperature | −20°C–+70°C |
Package weight | 34.4 lb |
INSTALLATION
This sliding gate opener works with gates weighing less than1400 lb (600 kg) and measuring less than 30 ft. in length. The drive mode uses a sprocket and chain transmission. This gate opener must be installed inside the enclosure or yard to prevent tampering with the device.
Installation drawing
- Gate opener;
- Wireless keypad (optional);
- Gate;
- Infrared sensor (optional);
- Alarm lamp (optional);
- Safety stop block;
- Chain;
- Remote control
Size of main engine and accessories
Size of main engine
Size of mounting base
Installation Procedures
Preparation work before installation
Please ensure that the sliding gate is correctly installed, the gate rail is
horizontal, and the gate can glide back and forth smoothly when moved manually
before installing the gate opener.
Cable installation
Please bury the motor & power cable and controlling cable in a PVC tube, and
use two PVC tubes to bury the motor/power cable and controlling cable
separately, so as to guarantee normal operation of the gate opener and protect
the cables from damage.
Concrete pedestal
Please cast a concrete pedestal measuring 19.69 x 13.78 in. with a depth of
7.87 in. in advance, so as to firmly install the gate opener.
Verify whether the distance between the gate and gate opener is suitable
before casting the pedestal.
Embedded screws
Main engine installation
-
Dismantle the plastic housing on the main engine before installation. Keep its fasteners handy.
-
The detachable mounting base should be assembled first as shown in Figure 5:
-
Assemble the machine engine to the mounting base as shown in Figure 6:
-
Prepare the power line to connect the mounting plate and main engine. The number of power supply cable core should not be less than 3 pcs, the sectional area of the cable core should not be less than 1.5 mm², and the length should be determined by the installers according to the situation at the installation site.
-
Unlock the main engine before installation: Take out the key cover; insert the key, and open the manual release bar till it rotates by 90° as shown in Figure 7. Then turn the output sprocket, which should rotate easily.
Chain installation
-
Close the gate. Connect the tie rod with the chain using its chain link; fasten the tie rod to the door connecting plate with washers and nuts as shown in Figure 8. If necessary, the elasticity of chain can be adjusted through the tie rod at both ends and the chain can be shortened. If it needs to be lengthened, make sure to use the same type of chain so it moves easily but securely.
-
If the door frame is square, please use the square screw as shown in Figure 9:
-
Installation of chain, small and big sprocket is shown in Figure 10:
-
Installation of sprocket cover is shown in Figure 11:
-
The distance between main engine and chain ends should be at least 11.8 in. (30 cm), as shown in Figure 12:
Warning
- To ensure safety, install safety stop blocks on both ends of the rails to prevent the gate from getting out of the rail. Before installing the main engine, make sure that the safety stop blocks are in place and capable of preventing the gate from moving out of the rail or the safety range.
- Please ensure that the main engine and its components have good mechanical properties, and the gate can operate flexibly when moved by hands before installing the main engine.
- Only use one control to drive one control board at one time. Otherwise, the control system and device may be damaged.
- An earth leakage circuit breaker must be installed where the gate movement can be seen, and the minimum mounting height should be 4.92 ft. to protect it from being touched.
- After installation, please verify that all mechanisms are operating correctly and whether the gate still moves flexibly under manual control after being unlocked.
Limit switch adjustment
- Use the manual release key to unlock the gate opener and manually move the gate to the predetermined position. Fix the magnetic limit switch block and close the clutch. Test its operation and adjust the position of the magnetic limit switch block incrementally until the gate reaches the desired open and close limit locations.
Installation of magnetic limit switch block is shown in Figure 13 and 14 (97 mm = 3.82 in., 35 mm = 1.38 in., 20 mm = 0.79 in.):
Note:
The default setting is right side mounting.
(Please refer to “Adjustment and operation” in 4.3.5 for adjustment
instructions.)
Control Board
Connections and Indicators Diagram
Open/Close: Light indicators for gate movement direction. When OPEN is on, the
gate should be opening. When CLOSE is on, the gate should be closing. If CLOSE
is on while the gate is opening, change the direction of the SW1 switch from
REV to FWD.
IR: The IR indicator light will continually be on until the IR sensor’s path
is obstructed.
CLLM: The CLLM light will be on when the gate’s closing limit is reached.
OPLM: The OPLM light will be on when the gate’s opening limit is reached.
OSC: The OSC light is an indicator light for the circuit board’s functioning.
Press TEST to test the circuit board’s operational state. If the OSC indicator
light does not shine when pressing TEST, the circuit board is non-functional.
Connection | Interface Terminals |
---|---|
Power | X4:PE, N, L |
Caution/Alarm Lamps | X2:D1, D2 |
External Button | X5: COM, OSC |
Photocell Infrared Sensor | X6: 24VDC, GND, I.R |
Features
- Pair with up to 20 different 433.92 MHz remote controls and with wireless keypads.
- Compatible with and easily connected to alarm lamps, external control buttons, and infrared photocell sensors.
- Auto-close functionality for improved security.
Gate Opener Installation
Step 1
Ensure your gate can glide back and forth smoothly by hand before installing
the gate opener.
Step 2
Toggle the Travel Direction Switch on the control board according to the
installation location of your automatic gate opener. Flip the switch to FWD
for right-mounted gate openers. Flip the switch to REV for left-mounted gate
openers.
Step 3
Wire the control board to your automatic gate opener and any compatible
accessories according to the Connections and Indicators Diagram in the Product
Overview section of this manual and the instruction manuals for the other
devices.
Step 4
Press the test button, Travel direction indicator (open) will light when the
gate is opening; Travel direction indicator (close) will light when the gate
is closing.
Remote Control
The included remote control uses single-button mode. Each button on the remote
control can pair with one control board. When pressed, the paired button will
open the gate if the gate is closed, close the gate if thegate is open, and
stop the gate if the gate is traveling.
CAUTION: To prevent accidents, DO NOT pair one button with two different
control boards.
The transmitter has been matched to the door opener when it leaves the
factory, No need to match again when the product is received.
Remote Control Pairing:
Step 1
Press the Remote Pair Button (AN1) on the control board. The Remote Signal
Indicator (LED2) will come on.
Step 2
Press the button on the remote control to be paired. The Remote Signal
Indicator will go off.
Step 3
Press the same button the remote control. The Remote Signal Indicator will
flash quickly then go off. DONE!
Remove All Paired Remote Controls:
Hold Remote Pair Button (AN1) on the control board until the Remote Signal
Indicator (LED2) goes out. DONE!
DIP Switches
The DIP switches on the control board control the external buttons control
mode and the auto-close time settings.
Switch 1: External Buttons Settings
ON = external button only can open the gate
OFF = external button can open/stop/close the gate
Switch Orientations | Auto-Close Time |
---|---|
2 ON 3 OFF | 15 seconds |
2 OFF 3 ON | 30 seconds |
2 OFF 3 OFF | 45 seconds |
2 ON 3 ON | Auto-Close Disabled |
Photocell Infrared Sensor Installation
Step 1
Remove the short wire connecting the I.R and GND interface terminals on the
control board.
Step 2
Install the photocell infrared sensor on your gate posts according the
instructions of your photocell infrared sensor.
Step 3
Connect the sensor to the control board according to the image below.
Note:
After setting or resetting the remote control, press the button within 100 ft.
(30 m) from the gate opener to test if the gate will open/close/stop on your
command. If not, check if the control board of the gate opener operates well.
Note:
To disengage the gate opener, move the gate to the middle position, then close
the clutch and press the open button of external button switch to open the
gate. If the gate opening direction is wrong, adjust the toggle switch SW1 on
the control board or exchange the two motor lines U and W. Please seriously
observe whether the motor can stop automatically when the gate is fully
opened. If the position cannot be adjusted correctly, please exchange limit
switch lines CLLM and OPLM.
PACKING LIST (STANDARD)
Maintenance
For the sake of safety, each gate should be equipped with an infrared
protector, and regular inspection is required. You should check
whether your device operates normally at least every month.
Troubleshooting
Problems | Possible Reasons | Solutions |
---|
The gate cannot open or close normally,
and LED light does not flash.| 1. The power is off.
2. The fuse is burned.
3. There is a problem with the control
board power wiring.| 1. Turn on/connect the power supply.
2. Check the fuse (code FU), replacing it if necessary.
3. Adjust the wiring as above.
The gate can open but cannot close.| 1. There is a problem with the photocell
wiring.
2. There is a problem with the photocell mounting.
3. The photocell is blocked.
4. The photocell’s sensitivity to obstacles is too high.
5. The hall switch parts are damaged.| 1. 1. If not connected, check if the
infrared port & GND short circuited.
2. If the IR sensor is connected, ensure the wiring is correct & the
photocell is N.C.
3. Ensure the photocell mounting position can be mutually aligned.
4. Remove the obstacle.
Remove any obstacles or reduce the photocell’s sensitivity.
5. Replace the parts.
Remote control doesn’t work.| 1.Low battery.
2. Remote control matching has not occurred.| 1.Replace the battery.
2.Rematch the remote control.
During operation, the motor generates
noise but the gate does not move.| 1.The capacitor is broken.
2.The capacitor is poorly connected.
3. Movement is obstructed.| 1.Replace the capacitor.
2.Check the capacitor wiring.
3. Adjust the motor or the gate to ensure no obstruction is occurring.
The gate does not stop at the limit
position during operation.| 1. The limit programming has a problem.
2.There is a problem with the mounting of the magnetic limit switch.| 1.
Check whether the limit switch wiring is consistent with the actual direction
of operation.
2.First check the distance btwn the magnetic limit switch and motor. Then,
check the height of the magnetic limit switch.
Leakage switch is tripped.| The power supply line or motor line has
short circuited.| Check and repair the wiring.
The remote control does not work at full
range.| The signal is blocked.| Adjust the external receiver antenna to 5
ft. (1.5 m) above the ground.
Contact Us
Thank you for choosing our products! If you have any questions or comments,
contact us at contact@b2csupportpro.com
and we’ll resolve your issue ASAP!
For a .pdf copy of the latest version of these instructions, use the
appropriate app on your smartphone to scan the QR
code to the right.
Documents / Resources
|
DOORADO SGO-EC08-00-BNHD-1 Smart Slide Single Automatic Gate Opener
Kit
[pdf] User Manual
SGO-EC08-00-BNHD-1, SGO-EC14-00-BNHD-1, SGO-EC06-00-BNHD-1, SGO-EC08-00-BNHD-1
Smart Slide Single Automatic Gate Opener Kit, Smart Slide Single Automatic
Gate Opener Kit, Single Automatic Gate Opener Kit, Automatic Gate Opener Kit,
Gate Opener Kit, Opener Kit, Kit
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>