DOORADO SGO-0000-00-BNHD-1 Slide Single Automatic Gate Opener Kit User Manual
- October 30, 2023
- DOORADO
Table of Contents
- Dear users,
- Safety Instruction
- Packing List
- Technical parameters
- Installation procedures
- Main engine installation
- Chain installation
- Limit switch adjustment
- control board
- Features
- Gate Opener Installation
- Remote Control
- DIP Switches
- Photocell Infrared Sensor Installation
- Troubleshooting
- Contact Us
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DOORADO SGO-0000-00-BNHD-1 Slide Single Automatic Gate Opener Kit
Dear users,
Thank you for choosing this product. Please read the manual carefully before assembling and using it. Please do not leave out the manual if you send this product to a third party.
Safety Instruction
Please ensure that the using power voltage matches with the supply voltage of gate opener (AC110V ); kids are forbidden to touch the control devices or the remote-control unit.
The remote-control unit is controlled by a single button mode. The indicator light on the remote-control unit will flicker when the button on it is pressed. Main engine and gate can be unlocked by disengagement wrench and the gate can move with manual operation after disengagement.
Please ensure that no one is around the main engine or gate when the switch is operated and it is usually demanded to examine the stability of installation. Please temporarily stop using if the main engine needs repairing or regulation.
The installation and maintenance of the products must be carried out by professionals.
Packing List
No. | Picture | Name | Quantity |
---|---|---|---|
1 | ![DOORADO SGO-0000-00-BNHD-1 Slide Single Automatic Gate Opener |
Kit](https://manuals.plus/wp-content/uploads/2023/06/DOORADO-
SGO-0000-00-BNHD-1-Slide-Single-Automatic-Gate-Opener-Kit-User-Manua-3.png)|
Main engine| 1
2| |
Manual release key| 2
3| |
Remote control| 2
4| |
Sprocket cover| 1
5| |
Chain| 19.68ft
6| |
Tie rod| 2
7| |
Square screw| 4
8| |
Round screw| 4
9|
| Door connecting plate| 2
10| |
Horizontal mounting plate| 1
11|
| Vertical mounting plate| 2
12| |
Foundation bolt M8| 4
13| |
Magnets & block| 1
14| |
Washer & Nuts| 1 bag
Technical parameters
This sliding gate opener is applicable to gate weight less than 600kg (1400Lbs), and length of the sliding gate should be less than 30ft. This gate opener must be installed inside the enclosure or yard for protection.
Maximum weight of gate | 600KG (1400Lbs) |
---|---|
Power supply | 110V/60Hz |
Motor power | 280W |
Gate moving speed | 40ft/min |
Remote control distance | ≥ 30m(10ft) |
Remote control mode | Single button mode |
Limit switch | Magnetic limit switch |
Noise | ≤58dB |
Working duty | S2, 15min |
Recording of up remote controls | 20 |
Frequency | 433.92 MHz |
Working temperature | -20°C ~ +70°C |
Package weight | 34.4Lbs |
Installation procedures
Preparation work before installation
Please ensure that the sliding gate is correctly installed, the gate rail is horizontal, and the gate can glide back and forth smoothly when moved by hands before installing the gate opener.
Cable installation
Please bury the motor & power cable and controlling cable with PVC tube, and use two PVC tubes to bury (motor & power cable) and (controlling cable) separately, so as to guarantee normal operation of the gate opener and protect the cables from damages.
Concrete pedestal
Please cast a concrete pedestal with the size of 19.69inch x 13.78inch and depth of 7.87inch in advance, so as to firmly install the gate opener. Please verify whether the distance between the gate and gate opener is suitable before casting the pedestal.
Main engine installation
a) Dismantle the plastic housing on the main engine before installation
and keep relevant fasteners properly;
b) assemble the detachable mounting base;
c) Assemble the machine engine to the mounting base;
d) Please prepare the power line for connecting mounting plate and main
engine (the number of power supply cable core shall not be less than 3 PCS,
the sectional area of cable core shall not be lower than 1.5mm² and the length
shall be determined by users according to the field situation) due to
different installation environments;
e) Please unlock the main engine before installation, the unlock method
is: take out the key cover, insert the key, and open the manual release bar
till it rotates by 90°. Then turn the output sprocket and the sprocket can be
rotated easily;
Chain installation
Close the gate; connect the tie rod with chain through chain link; fasten the tie rod to the door connecting plate by washers and nuts . If necessary, the chain can be shortened. If it need to be lengthened, make sure to use same type of chain. (US standard NO.41).
Use the round screws when the door frame is round; Use the square screws when the door frame is square.
Install the chain and sprocket cover as shown in the figure.
The distance between main engine and chain ends should be at least 11.81inch (30cm):
Warnings
- To ensure safety, install safety stop blocks on both ends of the rails to prevent the gate out of the rail. Before installing the main engine, make sure that the safety stop blocks are in place and whether it has the function of preventing the gate from moving out of the rail and out of the safety range.
- Please ensure that the main engine and its components have good mechanical properties, and the gate can operate flexibly when moved by hands before installing the main engine.
- In this product, one control can drive one main engine only, otherwise, the control system will be damaged.
- Earth leakage circuit breaker must be installed where the gate movement can be seen, and the minimum mounting height is 4.92ft to protect it from being touched.
- After installation, please check whether the mechanical property is good or not, whether gate movement after manual unlocking is flexible or not, and whether the infrared sensor (optional) is installed correctly and effectively.
Limit switch adjustment
Use the manual release key to unlock gate opener and manually move the gate to the predetermined position; fix the magnetic limit switch block and close the clutch; testing run after power on, slightly adjust the position of the magnetic limit switch block until the gate reaches the desired open and close limit location.
Installation of magnetic limit switch bock(97mm = 3.82inch,35mm = 1.38inch,20mm = 0.79inch)
control board
Connections and Indicators Diagram
Connection | Interface Terminals |
---|---|
Power | X4:PE, N, L |
Caution/Alarm Lamps | X2:D1, D2 |
External Button | X5: COM, OSC |
Photocell Infrared Sensor | X6: 24VDC, GND, I.R |
Features
- Pair with up to 20 different 433.92 MHz remote controls and with wireless keypads.
- Compatible with and easily connected to alarm lamps, external control buttons, and infrared photocell sensors.
- Auto-close functionality for improved security.
Gate Opener Installation
Step 1
Ensure your gate can glide back and forth smoothly by hand before installing
the gate opener.
Step 2
Toggle the Travel Direction Switch on the control board according to the
installation location of your automatic gate opener. Flip the switch to FWD
for right-mounted gate openers. Flip the switch to REV for left-mounted gate
openers.
Step 3
Wire the control board to your automatic gate opener and any compatible
accessories according to the Connections and Indicators Diagram in the Product
Overview section of this manual and the instruction manuals for the other
devices.
Step 4
Press the test button, Travel direction indicator (open) will light when the
gate is opening; Travel direction indicator (close) will light when the gate
is closing.
Remote Control
The included remote control uses single-button mode. Each button on the remote control can pair with one control board. When pressed, the paired button will open the gate if the gate is closed, close the gate if the gate is open, and stop the gate if the gate is traveling.
CAUTION: To prevent accidents, DO NOT pair one button with two different control boards. The transmitter has been matched to the door opener when it leaves the factory, No need to match again when the product is received.
Remote Control Pairing
Step 1
Press the Remote Pair Button (AN1) on the control board. The Remote Signal
Indicator (LED2) will come on.
Step 2
Press the button on the remote control to be paired. The Remote Signal
Indicator will go off.
Step 3
Press the same button the remote control. The Remote Signal Indicator will
flash quickly then go off. DONE!
Remove All Paired Remote Controls
Hold Remote Pair Button (AN1) on the control board until the Remote Signal Indicator (LED2) goes out. DONE!
DIP Switches
The DIP switches on the control board control the external buttons control mode and the auto-close time settings.
Switch 1: External Buttons Settings
ON = external button only can open the gate
OFF = external button can open/stop/close the gate
Switches 2 & 3: Auto-Close Time Settings
Switch Orientations | Auto-Close Time |
---|---|
2 ON 3 OFF | 15 seconds |
2 OFF 3 ON | 30 seconds |
2 OFF 3 OFF | 45 seconds |
2 ON 3 ON | Auto-Close Disabled |
Photocell Infrared Sensor Installation
Step 1
Remove the short wire connecting the I.R and GND interface terminals on the
control board.
Step 2
Install the photocell infrared sensor on your gate posts according the
instructions of your photocell infrared sensor.
Step 3
Connect the sensor to the control board according to the image below
Troubleshooting
Problems | Possible Reasons | Solutions |
---|---|---|
The gate cannot open or close normally, and LED does not light. |
- The power is off.
- Fuse is burned.
- Control board power wiring with problem.
|
- Switch on the power supply.
- Check the fuse (code FU), change the fuse if burnt.
- Re wiring according to instructions.
The gate can open but cannot close.|
- Photocell wiring with problem.
- Photocell mounting with problem.
- Photocell is blocked by objects.
- Sensitivity of obstacle is too high (Intelligent type).
- Hall switch parts is damaged (Intelligent type).
|
- If not connect photocell, please make sure that the infrared port and GND short circuit; if connect infrared sensor, please make sure the wiring is correct and the photocell is N.C.
- Make sure that the photocell mounting position can be mutually aligned.
- Remove the obstacle.
- Reduce the sensitivity of obstacle. 5.Change hall switch parts.
Remote control doesn’t
work|
- Battery level of the remote control is low.
- Remote control learning is not completed.
|
- Change the remote control battery. 2.Re-conduct remote control learning.
Press OPEN, CLOSE
button, the gate is not
moving, motor has noise.|
- Capacitor is broken.
- Capacitor is poor connected.
- Gate moving is not smoothly.
|
- Change capacitor.
- Check the capacitor wiring.
- According to the actual situation to adjust the motor or the gate.
Not stop at the limit position when opening / closing.|
- The limit direction is wrong.
- The mounting of magnetic limit switch with problem.
|
- Check whether the limit switch wiring is consistent with the actual direction of operation.
- Check whether the distance between magnetic limit switch and motor, and the height of the magnetic limit switch can reach up the mounting requirement.
Leakage switch tripped.| Power supply line short circuit or motor line short
circuit.| Check wiring.
Remote control working distance is too short.| Signal is blocked.| Connect
external receiver antenna, 1.5 meters above ground.
Contact Us
Thank you for choosing our products! If you have any questions or comments,
contact us at contact@b2csupportpro.com
and we’ll resolve your issue ASAP!
For a .pdf copy of the latest version of these instructions, use the
appropriate app on your smartphone to scan the QR code to the right.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>