INVACARE H140 Grab Handles
General
Introduction
This user manual contains important information about the handling of the
product. To ensure safety when using the product, read the user manual
carefully and follow the safety instructions. If you find that the font size
in the printed document is difficult to read, you can download the PDF version
from the website. Invacare reserves the right to alter product specifications
without further notice. In case of a serious incident with the product, you
should inform the manufacturer and the competent authority in your country.
Warranty Information
We provide a manufacturer’s warranty for the product in accordance with our
General Terms and Conditions of Business in the respective countries. Warranty
claims can only be made through the provider from whom the product was
obtained.
Compliance
This CE-marked medical device conforms to: EU Medical Device Regulation, ISO
13485, ISO 14971, REACH, EN 12182 and related standards.
Service life
The expected service life of this product is five years when used daily in
accordance with safety instructions and intended use, stated in this manual.
The effective service life can vary according to frequency and intensity of
use.
Limitation of Liability
Invacare accepts no liability for damage arising from:
- Non-compliance with the user manual
- Incorrect use
- Natural wear and tear
- Incorrect assembly or set-up
- Unauthorised modifications and/or use of unsuitable spare parts
Safety
Safety Information
WARNING!
Risk of Serious Injury or Damage Improper use of this product may cause injury
or damage.
WARNING!Risk of Falling!
- Before every use, check the product for damage and ensure that it is securely assembled.
- Do not use if defective.
- Do not make any unauthorised alterations or modifications to the product.
- Do not use as sports equipment or climbing aid.
- Only use suitable wall plugs and bolts for mounting the H320/1.
WARNING! Risk of Falling!
Excessive or intermittent loads can lead to breaking. Do not exceed the
maximum load, refer to 7 Technical Data, page 3
Labels and Symbols on Product
Identification Label
Components
Intended Use
Invacare Aqua (H140-H142) and Invacare Ocea (H320/1) are grab handles to be
fixed on walls with screws. The products are intended as support aids for
persons with mobility limitations when e.g. going in and out from a bathtub or
moving in the shower.
Indication : If used without an assistant, the users must be able to keep their own balance. There are no contraindications known when using the product as intended. For the maximum user weight, see 7 Technical Data, page 3 .
Scope of Delivery
The scope of delivery is shown in figure 1.
Scope of Delivery
The scope of delivery is shown in figure 1
Setup
WARNING! Risk of Falling!
Mount only to walls that have a sufficient load-bearing capacity
- Place the grab handle in the desired position against the wall, examples shown in Fig. 4 & 5, and mark the mounting points using a scribing tool (Fig. 6).
- Use a drill to make suitably sized holes at the points marked on the wall (Fig. 7).
- Fix the grab handle to the wall using the included wall mounting kit (Fig. 8). A wall mounting kit is not included for model H320/1.
- Only for H140 – H142: Place the screw covering caps on the fixing elements (Fig. 9).
- Grip the grab handle with one hand and carry out the desired body movement (Fig. 4 & 5).
Maintenance
General Maintenance Information
This product is maintenance-free, provided that the cleaning and disinfection instructions are adhered to.
Cleaning and Disinfection
General Safety Information
Take precautions for yourself and use appropriate protective equipment.
NOTICE!
Wrong fluids or methods can harm or damage
the product.
- All cleaning agents and disinfectants used must be effective, compatible with one another and must protect the materials they are used to clean.
- Never use corrosive fluids (alkalines, acid etc.) or abrasive cleaning agents. We recommend an ordinary household cleaning agent such as dishwashing liquid.
- Never use a solvent (cellulose thinner, acetone etc.) that changes the structure of the plastic or dissolves the attached labels
For cleaning and disinfection in clinical or long-term care environments, follow your in-house procedures.
Cleaning Intervals
NOTICE!
Regular cleaning and disinfection enhances smooth operation, increases the
service life and prevents contamination.
Clean and disinfect the product:
- before first use,
- regularly while it is in use,
- when it has been in contact with any body fluids.
Cleaning
NOTICE!
Maximum cleaning temperature: – 60 °C by hand
- Clean the product by wiping down all generally accessible surfaces.
- Dry the parts with a cloth.
Disinfection Instructions
- Method : Follow the application notes for the used disinfectant and wipe-disinfect all accessible surfaces.
- Disinfectant : Ordinary household disinfectant.
- Drying : Allow the product to air-dry.
After Use
Reconditioning
WARNING!
Risk of Falling Worn fastening elements can suddenly come loose and cause
falling. Always use new wall plugs and bolts when repositioning the product.
This product is suitable for reuse. To recondition the product for a new user, carry out the following actions:
- Inspection
- Cleaning and disinfection
For detailed information, see 5 Maintenance, page 3 . Make sure that the user manual is handed over with the product
Disposal
Disassemble the product and its components, so the different materials can be
separated and recycled individually. The disposal and recycling of used
products and packaging must comply with the laws and regulations for waste
handling in each country. Contact your local waste management company for
information
Technical Data
Dimensions, Weights and Materials
Prod- uct| Length [mm]| Max.
load force
| Product weight [kg]| Materi- **als*
---|---|---|---|---
H140| 250| **
120 kg
| 0.3| ****
ABS
H141| 400| 0.5
H142| 500| 0.6
H320/1
| 330
(angled 135°)
| ****
115 kg
| ****
0.18
| ****
PP
The tube diameter of H140 – H142 is 35 mm, the oval shape of H320/1 is 40 mm x 28 mm *All product components are corrosion resistant and do not contain natural rubber latex.
Environmental Parameters
Operating Conditions
Ambient temperature| 10 – 40 °C
Relative humidity| 15% – 93%, non-condensing
Storage and Shipping Conditions
Ambient temperature| 0 – 40 °C
Relative humidity| 30% – 75%, non-condensing
Belgium & Luxemburg: Invacare nv Autobaan 22 B-8210 Loppem
- Tel : (32) (0)50 83 10 10
- Fax : (32) (0)50 83 10 11
- marketingbelgium@invacare.com
- www.invacare.be
Nederland: Invacare BV Galvanistraat 14-3 NL-6716 AE Ede
- Tel: (31) (0)318 695 757
- nederland@invacare.com
- www.invacare.nl
Invacare GmbH Am Achener Hof 8 D-88316 Isny Germany Making Life’s Experiences Possible®
References
- | Invacare AT
- | Invacare BE
- | Invacare CH
- | Invacare DE
- | Invacare ES
- | Invacare IT
- | Invacare NL
- | Invacare PT
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>