CAUTION
READ THE INSTALLATION INSTRUCTIONS BEFORE USE
Keep these instructions for future references. Installation of this product
should be done byzz trained personnel. The shower must not be used by children
or persons with reduced physical, sensory or mental capabilities, or by
persons without experience or knowledge in its use, unless they are supervised
by a person responsible for their safety or receive prior instruction in its
use. Children should be supervised to ensure that they do not play with the
watering can. Strict supervision should be maintained if children or disabled
persons come to use any type of household appliance or are near it.
INSTALLATION REQUIREMENTS
It must be connected directly to the fixed wiring and to the ground.
Do not install in places where the water may freeze.
The electrical circuit must be exclusive and independent, at a voltage of 127
V- with a minimum capacity of 50 A
Use 10 AWG wire for distances less than 100 feets
Use 8 AWG wire for distances longer than 100 feets
WARNING Do not operate the shower when the water side is frozen. me ouolet
must not be connected to any tap or equipment other than as specified in these
instructions. Electrical specifications: 127 V- 60 Hz 5 400 W
Water Resistivity
At 22°C must not be less than 1 300 0cm.
PARTS
- Pressure reducer
- Water inlet nipple, 1 /2″ (13 mm) thread
- Cable green – yellow (earth ground)
- White and blue wire (electrical circuit)
- Temperature selector: Cold, Warm, Hot and Ver6.
- Water heating chamber
- Diffuser
- Outlet pipe for connecting the spray hose
- Water outlet plug
- Diffuser removal guide
- Hose holder with screw for the hose with spray
**** Before start the installation of the electric shower, very that the electric circuit breaker is turned off, that the voltage is 127 V– and the wires are 10 4AWG or 8 AWG depending on the distance. For correct operation, the height between the shower and the watering must be between 6.5 ft and 33 ft
INSTALLATION
-
Before installing the electric shower, Teflon tape.% let the water run througt hepipe to remove the dirt.
-
The water pipe outlet must have an internal 1/2″ (13 mm) thread connection to assemble with the shower.
-
Screw the shower head to the water supply pipe and use Teflon tape to seal the connections, hand tighten without using tools to prevent damage to the shower head.
-
The electric shower should be installed at a height of 6.5 ft from the floor.
-
Do not remove the reduction gear if the water tank is higher than 16 ft
-
If the water pressure is too low and the water flow is too poor, remove the pressure reducer on the sprinkler thread.
-
The white and blue wires are connected to the electrical circuit (line and neutral) and the green – yellow wire goes to the earth ground.
-
When connecting the wires to the power supply, make sure that they are perfectly joined and insulated (use insulating tape only).
-
To cover the installation cables, you can use a gutter.
-
When the installation is finished, turn up the switch.
OPERATION
When you open the water tap of the electric shower head, it will be activated
automatically. Thelectric shower has 4 temperature options. Select the desired
temperature using thtemperature selector.
CLOSE THE WATER TAP EVERY TIME YOU WANT TO CHANGE THE TEMPERATURE
WARNING The shower can heat the water to a temperature higher tnan that
suitable to bathing. Select the water temperature appropriately. Children and
elderly people, sick, physicaor mentally impaired people should be supervised
when using the product.
TO USE THE SPRAY HOSE:
Connect the hose to the outlet. To open, pull and to close, push. If you do
not want to connect the spray hose, place the plug on the outlet.
MAINTENANCE AND CLEANING
‘To clean the electric shower head, turn the diffuser counterclockwise, clean the holes with a brush. Replace the cover by turning it clockwise.
IMPORTANT: NEVER CONNECT THE ELECTRIC SHOWER HEAD TO PLUGS, SOCKETS, CONTACTS, MULTIPLE SOCKETS, ETC.
TROUBLESHOOT!NC
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
The shower doesn’t work | Low water pressure | Place the water tank at a minimum |
height of 6.5 ft and a maximum height of 33 ft above the shower
The switch is OFF| Turn the switch into the ON position
Burned fuse| Replace fuse (50 A minimum)
Temperature selector is in the cold setting| Turn the temperature selector to
Lukewarm, hot or very hot position
The shower heats up very little| High water volume, ambient temperature below
10 °C| Switch temperature selector to very hot position Reduce the water flow
with the stopcock Place the water tank at a minimum height of 6.5 ft and a
maximum height of 33 ft above the shower. Remove the pressure reducer.
The shower heats up too much| Low water volume, ambient temperature above 25
°C| Switch temperature selector to Lukewarm position Place the water tank at a
minimum height of 6.5 ft and a maximum height of 33 ft above the shower.
Remove the pressure reducer.
This product is guaranteed for 1 year. To make the warranty valid or to
purchase parts and components, you must present the product at Corregidor 22,
Centro, Ale. Cuauhtemoc, CDMX C.P. or 6060 or at the store where you purchased
it, or at one of the Truper Service Centers® listed in the appendix of the
warranty policy and/or at www.truper.com.
Transportation costs resulting from compliance will be covered by Truper®. For
questions or comments, call 800-690-6990. Manufactured by Truper S.A. de C.V.
Parque Industrial 1, Jilotepec, Edo de Mex. ZIP 54240. MADE IN MEXICO
Stamp of the commercial establishment.
Delivery date
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>