MEM TQ1-6080 Large Format Pneumatic Heat Press Instruction Manual

October 30, 2023
MEM

TQ1-6080 Large Format Pneumatic Heat Press

Operating Instructions for the Heat Press MEM TQ1-6080/80100

Congratulations on purchasing the MEM heat press!
Please read these operating instructions carefully to start production with your press without problems. Reproduction of these operating instructions in any form requires the written approval of MEM. MEM reserves all rights to change technical data and product features. MEM does not assume any liability for direct or indirect damage resulting from the use of this product. Version 1.2 (09.06.2022)

Brief Overview
The MEM TQ1-6080/80100 is a pneumatic double station heat press with a self-pressure balancing system. It has an adjustable air pressure by air reducing valve with water separator. The product is CE certificated and RoHS certificated. It also comes with a lifetime factory on-line service.

MEM TQ1-6080/80100 pneumatic double station heat press
The design of the MEM presses combines a heavy-duty solid industrial grade pressing framework with high quality electric components. This provides the operator with the best possible features and equipment needed for today’s various heat transfer applications.
Using the MEM TQ1-6080/80100 heat press, all common heat transfer processes (flock,
flex, sublimation, transfer, Inkjet-­flex etc.) can be conducted professionally and with
highest productivity. The desired settings can be set easily with the temperature controller. The pneumatic pressure can be regulated smoothly with the air reducing valve. With the restriction valve on the solenoid valve, the press and lift speed could be adjusted.

Short overview MEM TQ1-6080/80100 heat press

  • Self-pressure balancing system.
  • Adjustable air pressure by air reducing valve with water separator.
  • CE certificated and RoHS certificated.
  • Lifetime factory on-line service.

Safety Precautions
Please read these instructions and safety precautions carefully before using your press for the first time! Do not open the cover or attempt to modify the machine yourself without instruction. In case you are requested by the MEM customer support to open the heating plate cover, follow their instructions. If you cannot observe one or more of the safety precautions above, or if you are not sure whether all points are satisfied, please contact our Technical Support Department.

  • Never reach into the heat press with your hands when it is connected to the power supply, particularly when it is switched on and heated up – danger of severe burns!
  • Do not open the cover or attempt to modify the machine yourself without instruction.
  • In case you are requested by the MEM customer support to open the heating plate cover, please make sure you are wearing respiratory protection and only touch the contained insulation wool with gloves. Any disposal of the wool must be contained in a closed bag.
  • Ensure that liquids and metal objects do not get into the inside of the heat press.
  • Ensure that the power socket used is grounded. Note that it is only permissible to operate a heat press from a power socket protected by a ground fault protection switch.
  • Disconnect machine from power outlet when not in use!
  • Never operate the heat press within the reach of children and never leave the machine unsupervised when switched on.
  • Ensure that the machine is used only in dry rooms.
  • Pay attention that the used compressor is attuned to the air consumption and the pressure

If you cannot observe one or more of the safety precautions above, or if you are not sure whether all points are satisfied, please contact our Technical Support Department.

Machine Description

MEM-TQ1-6080-Large-Format-Pneumatic-Heat-Press-1

  • a. Air reducing valve (not shown)
  • b. Solenoid valve
  • c. Press button
  • d. Temperature controller
  • e. Manual/auto model switch
  • f. Emergency stop button
  • g. Heat plate
  • h. Bottom platen
  • i. Handle
  • j. Bottom stand
  • k. Height adjustable foot

The TQ1-80100 has a controller with a SET button to enter parameter setting interface. Press and hold SET button to exit parameter setting interface. Press down key to decrease the corresponding parameter value. Do not change parameters except Pb and SL2 without our instruction. Parameter code Pb SL2 Function Temperature calibration: If measured temperature 1 or 1 lower than the showing temperature, decrease the value 1. 0: Celsius () 1: Fahrenheit ()

Pneumatic Connection
The TQ1-6080/80100 requires an air compressor with a minimum of 1500w (5 hp) and 60L (16 gallon) hold tank. Connect a 5mm inner diameter (usually 8mm outer diameter) air hose to the machine. Charge the compressor to 0.6-0.7 Mpa, up to 0.8 Mpa (120 psi) if possible. Set the desired pneumatic pressure on the air reducing valve of the heat press by pulling up the cap at the top end and then turning it. After the pressure is set, push the cap back down. The set pressure should be lower than on the manometer of the compressor. Commonly used pressures are between 0.4 to 0.6 Mpa (60 to 90 psi).

Power Supply
The heat press requires a power supply. Please ensure that it is connected to a suitable power outlet.

Operation of Solenoid Valve
On the side of the solenoid valve, there are two silver/golden screws which restrict the air flow speed of the cylinder. If the screws are screwed out, it accelerates up/down process of the cylinder. When the screws are screwed in, it slows down up/down process of the cylinder. Fix the respective setting with the corresponding counter nuts by tightening them by hand.

Maintenance and Cleaning
Maintenance work should always be accomplished with the press switched off and cooled down. The plug must first be disconnected from the power socket. Consult Technical Support before carrying out any maintenance work. Clean the press regularly with a soft cloth and mild household cleaner to remove adhesive residues etc.

Controller

With the temperature controller, temperature (°C and °F) and pressing time can be adjusted. The Set Value are showing the setting value, the Temperature digits are showing the actual value. Counter (reset after power off) function that counts the number of transfers that have already been made during the current session could be enabled, contact MEM for counter function enable instruction. MEM-TQ1-6080-Large-Format-Pneumatic-Heat-
Press-3Do not change parameters except Pb and SL2 without our instruction. MEM-TQ1-6080-Large-Format-Pneumatic-Heat-
Press-4

Operation

Pneumatic connection

  • TQ1-6080/80100 requires air compressor with minimum 1500w (5 hp) and 60L (16 gallon) hold tank.

  • Connect 5mm inner diameter (usually 8mm outer diameter) air hose to the machine.
    Charge the compressor to 0.6-0.7 Mpa, up to 0.8 Mpa (120 psi) if possible.

  • Set the desired pneumatic pressure on the air-reducing valve of the heat press by pulling up the cap at the top end and then turning it. After the pressure is set, push the cap back down. The set pressure should be lower than on the manometer of the compressor. Commonly used pressures are between 0.4 to 0.6 Mpa (60 to 90 psi).

Power supply
Connect the heat press to at least 6mm² (9 AWG) power cord.

Operation of solenoid valve

  • On the side of the solenoid valve there are two silver/golden screws which restricting the air flow speed of the cylinder.
  • If the screws are screwed out, it accelerates up/down process of the cylinder.
  • When the screws are screwed in, it slows down up/down process of the cylinder
  • Fix the respective setting with the corresponding counter nuts by tightening them by hand.

Maintenance and cleaning

Maintenance work should always be accomplished with the press switched off and cooled down. The plug must first be disconnected from the power socket. Consult Technical Support before carrying out any maintenance work.
Clean the press regularly with a soft cloth and mild household cleaner to remove adhesive residues etc.

Technical data

Model TQ1-6080/80100
Voltage and power 220-240V; 6000W;    Single phase
Time Range 0-999sec.
Max. Temp. 260°C / 500°F
Heat plate size 60x80cm/80x100cm

Dimensions(LWH)

| TQ1-6080: 1120x820x1410mm (44″x32″x56″)


TQ1-80100:


Shipping Dimensions(LWH)

| TQ1-6080: 1220x910x900mm (48″x36″x36″)


TQ1-80100:


Shipping Weight

| TQ1-6080: 190kg (418lbs)


TQ1-80100:

Max. press thickness| 70mm

Circuit diagram TQ1-6080

MEM-TQ1-6080-Large-Format-Pneumatic-Heat-Press-7

Circuit diagram TQ1-80100

MEM-TQ1-6080-Large-Format-Pneumatic-Heat-Press-8 Statement of Conformity

CE certification
We herewith declare that the product meets the provisions of the following EC Directives and Harmonized Standards:
Certificate Number : M.2020.206.C9752

  • 2006/42/EC Machinery Directive
  • 2014/35/EU Low Voltage Directive
  • Related Standards: EN ISO 12100:2010, EN 60204-1:2018

RoHS test
We herewith declare that the product conforms to RoHS Directive 2011/65/EU Annex II amending Annex (EU)2015/863 and amending Annex (EU)2017/2102.
Report No. : B-R2203A0560

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals