SHX90LEF2202 Air Dehumidifier User Manual

June 10, 2024
SHX

SHX90LEF2202 Air Dehumidifier

SHX90LEF2202-Air-Dehumidifier-product

Product Information

The SHX90LEF2202 is a 90L dehumidifier/building dryer that is designed to remove excess moisture from the air. It has an automatic defrost function that switches off the machine when frost builds up on the evaporator coil. The machine has a control panel, movable rubber wheels, and handles for easy transportation. It also has a dust filter that should be cleaned every week to ensure efficient functioning. The machine has several operating modes including automatic dehumidification, continuous dehumidification, and child lock safety function. The product dimensions are 540 x 800 x 350mm and it weighs 40kg.

Product Usage Instructions

  1. Ensure that the machine is placed on a stable surface.
  2. Insert the dust filter into the machine.
  3. Connect the machine to a power source.
  4. Press the power button on the control panel to switch on the machine.
  5. Select the desired operating mode (automatic dehumidification, continuous dehumidification, or child lock safety function) using the control panel.
  6. When the dust filter becomes dirty, remove it and clean it using a vacuum cleaner or by washing it with water.
  7. If the machine stops functioning due to frost buildup on the evaporator coil, switch off the machine and wait for it to defrost before switching it back on again.
  8. If any error codes appear on the display screen, refer to the user manual for troubleshooting instructions or contact customer service for assistance.

NOTICE AND SAFETY INSTRUCTION

IMPORTANT INFORMATION ON SAFETY, LOCATION, FILLING AGENT AND ELECTRICAL CONNECTION.
Only use this appliance in accordance with the guidelines in the operating instructions. Any other use not recommended by the manufacturer could result in fire, electric shock or personal injury.

  1. This appliance is intended for indoor dehumidification only and must not be used for any other purpose.
  2. Remove the packaging and make sure that the unit is not damaged. If in doubt, do not use the appliance and contact the service centre or your dealer.
  3. If the unit has a defect, switch it off and contact your dealer or the customer hotline.
  4. If the power supply cable is damaged, it must be replaced by the manufacturer or an authorised service centre in order to avoid all possible risks.
  5. Always and only contact service centres authorised by the manufacturer for any repairs.
  6. You can find the service centres online at www.shx.at
  7. Before connecting the appliance to the mains, check that the type of current and mains voltage correspond to the specifications on the appliance rating plate. The appliance should be installed in accordance with the relevant national wiring regulations.
  8. The electrical socket in which you connect the unit must not be defective or loose and must be suitable for the required current load and, above all, reliably earthed. If in doubt, have your electrical installation checked by a qualified electrician.
  9. Avoid using an extension cord as it could overheat and cause a fire.
  10. It is forbidden to adapt or modify the characteristics of this appliance in any way and use only spare parts and accessories recommended by the manufacturer. (Non-compliance will result in the loss of the guarantee and warranty)
  11. Do not allow children to play with the appliance.
  12. Do not allow children to play with the packaging.
  13. THERE IS A RISK OF SUFFOCATION IF SMALL PARTS ARE SWALLOWED!
  14. Children under the age of 8 and persons with reduced physical, mental, sensory or spiritual capabilities or lack of experience and knowledge should not use this appliance unless they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  15. Do not leave the appliance unattended. If you leave the room, always switch off the appliance.
  16. Do not twist or bend the power cord. If the mains cable is damaged, it must be replaced by a specialist from the manufacturer’s customer service department or similar in order to avoid danger.
  17. Do not use the appliance with wet hands.
  18. Do not use the appliance outdoors.
  19. Never cover the appliance.
  20. Do not operate the appliance in areas where gas, oil or sulphur are present.
  21. Do not use the appliance near water or strong jets of water, e.g. in flooded basements, next to swimming pools, bathtubs or showers. Do not place the appliance in water or other liquids.
  22. Make sure that no water enters the unit.
  23. Do not place the appliance near heat sources (e.g.: next to heating systems) and avoid direct sunlight.
  24. Keep a minimum distance of at least 50 cm from flammable substances (e.g. alcohol) or pressurised vessels (e.g. spray containers).
  25. Do not place heavy or hot objects on the appliance.
  26. Do not place sticks or hard objects in the appliance to avoid faults or damage. In case of any abnormality (e.g. burning smell), switch off the appliance and unplug the power cord.
  27. Place the appliance on a stable and level surface. Please place the appliance on a flat, open surface and keep a distance of at least 50 cm between the appliance and surrounding objects.
  28. Never insert fingers, pins or other objects into the unit and make sure that the air inlet and outlet are never blocked.
  29. When inserting the drip hose, always make sure to press it firmly into the dehumidifier.
  30. The operating temperature is between 5°C and 32°C.
  31. PLEASE NOTE The dehumidifier has an automatic defrost function. If frost forms on the evaporator coil, the compressor switches off automatically, but the cooler continues to run until the frost dissipates. When the coil is completely thawed, the compressor starts automatically and dehumidification continues.
  32. Unplug the appliance when not in use.
  33. Always switch off the appliance before unplugging it from the mains.
  34. Do not pull the power cord to disconnect the appliance from the mains. Always pull the plug to unplug the mains cable.
  35. Do not handle the plug with wet hands to avoid electric shock.
  36. Store the appliance vertically in a safe, dry place out of reach of children when not in use and do not cover the appliance with plastic packaging.
  37. Keep the appliance in good condition by maintaining and cleaning the appliance. If you have any questions about maintenance, you can contact the customer hotline/service centre authorised by the manufacturer.
  38. Do not use insecticide sprays or other flammable substances near the unit.
  39. Do not scratch the exterior of the appliance with sharp objects. 40.
  40. Do not spray oil or water into the unit. Do not clean the unit with water, but only wipe it with a soft, semi-moist cloth.
  41. Do not wipe the machine with chemical solvents such as benzene, petrol, alcohol, etc. If the machine is very dirty, use a neutral cleaner.
  42. Do not turn the machine upside down.

SPECIFIC INFORMATION ON REFRIGERANT R290

  1. R290 is a refrigerant according to the EC environmental guidelines.
  2. The refrigerant is odorless.
  3. The appliance should be installed in a room where there are no ignition sources in operation (e.g.: open fire, gas and electrical appliances in operation with open heat source)
  4. Do not perforate or burn the air conditioner.
  5. Make sure that the cooling circuit is not drilled.
  6. Non-ventilated rooms in which the appliance is installed, operated or stored must be designed in such a way that any loss of refrigerant does not build up. This avoids the risk of fire or explosion caused by ignition of the refrigerant caused by electric ovens, cookers or other sources of ignition. The device must be stored in such a way that no mechanical damage can occur.
  7. Persons operating or intervening on a refrigeration circuit shall be in possession of a valid certificate issued by an authorized authority certifying their expertise in the handling of refrigerants by a rating specification recognized by the industry associations.
  8. The repair work must be carried out according to the instructions of the manufacturer of the device. Repair and maintenance operations that require the use of additional specialist personel are to be carried out under the supervision of a specialist who is responsible for the handling of flammable refrigerants.

RECYCLING
The packaging materials can be recycled. Therefore it is recommended to dispose of them in sorted waste.

DISPOSAL
The crossed-out bin symbol requires the separate disposal of waste electrical and electronic equipment (WEEE). Electrical and electronic equipment may contain hazardous and environmentally hazardous substances. Therefore, do not dispose of it in unsorted residual waste, but at a designated collection point for waste electrical and electronic equipment. This helps to protect resources and the environment.
For more information, contact your dealer or the local authorities.

DECLARATION OF CONFORMITY

We hereby confirm that this article complies with the basic requirements, regulations and directives of the EU. You can view the detailed declaration of conformity at any time under the following link: www.shx.at/downloads.

Errors and technical changes are reserved.
www.shx.at.

DESCRIPTION OF THE DEVICE

Front

SHX90LEF2202-Air-Dehumidifier-fig- \(1\)

Back side

SHX90LEF2202-Air-Dehumidifier-fig- \(2\)

Insert the filter
  • Insert the filter into the rear housing so that the filter cleans the air.
  • The filter can be removed by pulling it as shown in the illustration below and inserted back into the unit.

SHX90LEF2202-Air-Dehumidifier-fig- \(3\)

Handle mounting
  • Secure the handles to the unit with the enclosed hexagon socket screws (ST6 x 45).
  • Fix the handle and screw the four screws alternately into the four holes on the left and right side.
  • The handle is now mounted.

Transport wheels
For easier transport, the unit is equipped with transport wheels. Place the unit on a level and firm surface. The distance to walls or other objects must be at least 50 cm. Before using the unit, make sure that both the air inlet and the air outlet are free of obstacles and not blocked. Connect the appliance to an earthed socket.

Control panel

SHX90LEF2202-Air-Dehumidifier-fig- \(5\)

Control indicators
  • defrost program activate
  • pump activate
  • low speed
  • high speed
  • pump error
  • continuous dehumidification
  • auto dehumidification
  • Timer
  • children lock
Operation
  • ON/OFF-Button:
    Press this button to turn the device on and off.

  • MODE-Button:
    In the turn-on state or in the timed state, you can use this key to select between the automatic dehumidification and continuous dehumidification operating modes.

  • Child lock:
    Press and hold the MODE button for 3 seconds to activate the key lock. Hold this button again for 3 seconds to unlock

  • TIMER-Button:
    Press this button to enter the timer function. Start the water pump drainage function aufter continuous pressing for 3 sec.

  • FAN-Button:
    Press this button to change the fan speed, you can choose between a high or low speed.

  • UP/DOWN-Button:
    In the automatic dehumidification mode, you can set the humidity with the UP/DOWN key. The setting range for the humidity is 30-80%.

FUNCTIONAL DESCRIPTION

Setting for automatic switching off
While the device is running, press the TIMER-Button to enter the timer setting. With the timer-button you can set the time from 0 to 24 hours, each time you press it, the set time increases by 1 hour. If the timer button does not move within 5 seconds, it means that the time is confirmed. Once the set time has elapsed, the device automatically turns off.

Settings for automatic switch on
In the standby state of the device, press the timer key to enter the timer setting. Set the desired time with the timer button in the same way as when the timer is turned off. If the timer button does not trigger any action within 5 seconds after completing the setting, it means that the time is confirmed.

Automatic dehumidification mode
For automatic dehumidification, activate the option with the MODE-Button. If the room humidity is > set humidity + 5%, the compressor starts and the fan runs at the set air speed. If the room humidity is < set humidity – 5%, the compressor will stop and the fan will not run. If the room humidity is between set humidity + 5% and set humidity – 5%, the whole unit runs in the initial operating condition. The initial value of the set humidity is 50%.

Note:
With this model, the compressor switches off when the room humidity is less than -5% of the set humidity, the fan continues to run at the set air speed.

Continuous dehumidification mode
For continuous dehumidification, activate this option with the MODE-Button. Then the compressor will start regardless of the relative humidity in the room, the fan will run at the highest speed by default and the fan speed can be adjusted.

Child lock function
Press and hold the MODE key 3 sec. to activate or deactivate the key lock. (All buttons on the control panel are disabled when the key lock is activated).

APPLICATION

Dehumidification
The appliance is continuously dehumidified and the drain hose (12 mm inner diameter) is attached to the side of the device to drain the water. Look for the water drainage connection on the left side and pull out the water stopper.

Connect a drain hose with 12 mm inner diameter to the water drainage connection.

The following figure illustrates the connection between continuous dehumidification.

Note:
Before operating the device, make sure that the water plug is removed and the drain hose is connected to the drain connection. The height of the water pipe end must be at least 10 cm below the height of the unit’s connection, and the hose must be smooth and not kinked, otherwise, it will not drain properly.SHX90LEF2202-Air-Dehumidifier-fig- \(9\)

Dehumidification with the water pump
Check that the water plug of the continuous drain is inserted and ensure the water plug is inserted.

Insert a water hose with an inner diameter of 5 mm into the water drainage connection of the pump (access is possible at any angle).

Note

  • Before starting the unit, connect the water connection to the continuous water connection and connect the hose to the pump connection so that the floor does not get wet.
  • Tip: Before using the unit with the continuous dehumidification pump, you must pull out the water plug and connect the waste water hose to the continuous dehumidification connection.

CLEAN THE DUST FILTER

To ensure efficient operation of the dehumidifier, you should clean the dust filter after each week of operation. To do this, please follow the steps below:

  1. Switch off the appliance before cleaning, then wait a few minutes and unplug the appliance to disconnect it from the mains.
  2. Remove the inserted air filter.
  3. Use a Vacuum Cleaner to remove the dust accumulated on the filter.
  4. If the grille and the filter are very dirty, soak the filter in hot water and rinse it several times – the water temperature should not exceed 40°C, however. Clean with a Vacuum Cleaner.
  5. Allow the dust filter to dry thoroughly after washing and put it back into the dehumidifier.

NOTE
However, we recommend cleaning the filter as described after each week of operation to ensure that the appliance works as efficiently as possible.

NOTE
Never use the appliance without the filter.

CLEANING THE HOUSING

Before cleaning, switch off the unit, then wait a few minutes and unplug the power cord to disconnect the unit from the mains.

Clean the unit with a moderately damp cloth and then wipe it with a dry cloth.

  • Never use petrol, alcohol or solvents to clean the unit – this could be dangerous.
  • Do not spray insecticides or similar agents on the dehumidifier.

ACTIVITIES AT THE BEGINNING/END OF THE SEASON

END-OF-SEASON ACTIVITIES
Switch off the unit and disconnect the mains plug. Clean the filter and replace it. Pack the unit and store it in a cool, dry place.

CHECKS AT THE BEGINNING OF THE SEASON
Check that the power supply cable is in order and that the earthing is functional. Follow the installation and safety instructions carefully.

TROUBLESHOOTING

Before contacting our customer hotline/service centre, please check whether the error can be rectified using the instructions below.

Error code description

Code Description
P1 The device is in defrost state
CL The device is in a dry state
LC The machine is in the lock screen function
Status possible causes
--- ---



Dehumidifier does not run

| Is the power plug plugged in?| Plug the power supply into the socket.


Is the room temperature below 5°C or above 32°C?

| Please check the room temperature and note that the dehumidifier can only be activated from 5°C – 32°C.


The dehumidification function does not work

| Is the temperature or humidity in the room too low?| In dry seasons, the dehumidification capacity is reduced.
Are the air outlet and the air inlet blocked?| Remove all objects blocking the air outlet and air inlet.
No air circulation| Is the air filter blocked?| Clean the air filter.
Unusual noises during operation| Is the device tilted or unstable due to improper setup?| Please place the dehumidifier in a stable place.
---|---|---
Is the air filter blocked?| Clean the air filter.
A “puffing” sound can be heard| The sound of the refrigerant flow is normal
Leaking water| Loose drain connections| Plug in the drain hose and water pipe.
Drainage system clogged| Clean clogged drains
Frost on the coils| Low ambient temperature, in a state of pending defrost.| The unit has an automatic defrost function.
Error light water pump flashes| Clogged water pump discharge pipe| Checking the pump discharge for ease of movement
Damaged water pump| Pump replacement

Error Codes

E1 Fault in the coil sensor detection Contact the customer service
E2 Temperature sensor fault Contact the customer service
E6 Fluoride protection, stopping the compressor Contact the customer service

TECHNICAL DATA

Technical information

Input voltage| 220-240V
Frequency| 50Hz
Rated Power| 1400 W
Refrigerant| R290
Sound power level| 65dB(A)
Dimension| 540 x 800 x 350 mm
Weight| 40kg
Contact addresses for further information:| Schuss Home Electronic GmbH Scheringgasse 3, A-1140 Wien Tel: +43 (1) 97 0 21 – 0

www.shx.at

FB-Nr: 236974 t / FB-Gericht: Wien

WARRANTY

By purchasing an SHX quality product you have acquired an innovative, long- lasting, and reliable item.

For this SHX device, we grant a warranty of 2 years from the date of purchase, valid in Austria only. In the unlikely event that service work is required on your device in this period, we warrant free repair (spare parts and labour) or (subject to Schuss’s decision) to replace the product. In the event that neither repair nor exchange makes sense from an economical perspective, we reserve the right to issue a credit based on current value.

When dealing with air conditioning devices you should always contact the customer hotline first (see the label on the device or the title page of the instruction manual), in case of fans contact your dealer or us directly. Please note that repair not performed by the authorized workshop in Austria immediately renders this warranty void.

This warranty does not include:

  • Repair of replacement of parts due to normal wear
  • Damage due to non-compliance with the instruction manual
  • Devices that are used commercially – even in part
  • Devices damaged by external forces (falling, impact, cracking, improper use etc.) as well as aesthetic wear
  • Devices that have been used improperly
  • Devices that were not opened by our authorized workshop.
  • Damages are caused by improperly closed condensation drains on air conditioning devices or improperly inserted water containers.
  • Unfulfilled customer expectations.
  • Damage is caused by force majeure, water, lightning, and overvoltage.
  • Devices on which type denomination and/or serial number on the device have been erased, rendered illegible or removed.
  • Service work not performed by our authorized workshops, transport costs to an authorized workshop or us and back as well as associated risks.

Please note that within the warranty period we charge a flat rate of 60 € (indexed as per consumer price index 2010, June 2015) in case of operating errors or if no fault can be found. The total warranty period of 2 years is not extended if warranty service is performed (repair or device replacement).

The 2 year warranty is only valid if the original invoice (must contain name and address of the dealer as well as full device name) and the respective warranty certificate are produced, on which the device type and serial number (can be found on the box and the device’s rear or bottom) are to be noted! Only statutory warranty coverage applies if the warranty certificate cannot be produced!
Please note that the statutory warranty coverage is not altered by this warranty and that it applies in full regardless.
Schuss Home Electronic GmbH and its vicarious agents are only liable for damages in case of gross negligence or intent. Liability for loss of profit, expected but not incurred savings, consequential damages and damages from third-party claims is excluded in any case. Damages to or for recorded data are always excluded from the liability for damages.
Congratulations on your choice. We hope you will enjoy using your SHX device!

ADDRESS
Schuss Home Electronic GmbH 1140 Vienna, Scheringgasse 3
Tel.: +43 (0)1/ 970 21SHX90LEF2202-Air-Dehumidifier-fig-
\(12\)

Together with the device, this warranty certificate must be handed to the authorized workshop or dealer you bought the device from in the event of a warranty claim!

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SHX User Manuals

Related Manuals