Specifications
-
Product Name: Air Conditioners SA15AY VantixTM Line iM Air
Conditioners -
Cooling Efficiencies: Up to 16.0 SEER / 13.0 EER
-
Nominal Sizes: 1.5 to 5 Tons [5.3 to 17.6 kW]
-
Cooling Capacities: 17.1 to 56.0 kBTU [5.0 to 16.4 kW]
-
Refrigerant Type: R-454B
Product Usage Instructions
Installation
1. Ensure the unit is placed on a level surface with proper
clearance for airflow.
2. Connect the necessary electrical wiring according to the
provided manual.
3. Install the required filter drier and check all connections
for leaks.
Operation
1. Power on the unit using the designated controls.
2. Set the desired temperature using the thermostat.
3. Select the fan speed and mode (cooling, heating, fan only) as
needed.
Maintenance
1. Regularly clean or replace air filters to ensure optimal
performance.
2. Check refrigerant levels and system components for any signs
of damage.
3. Schedule professional maintenance at least once a year to
keep the unit in top condition.
Frequently Asked Questions (FAQ)
Q: What refrigerant type does the SA15AY air conditioner
use?
A: The SA15AY air conditioner uses R-454B refrigerant.
Q: How often should I clean or replace the air filters?
A: It is recommended to clean or replace the air filters every
1-2 months for optimal performance.
Q: Can I install the air conditioner myself?
A: While installation manuals are provided, it is recommended to
hire a professional HVAC technician for proper installation.
“`
Air Conditioners SA15AY
VantixTM Line iM Air Conditioners
SA15AY
Cooling Efficiencies up to: 16.0 SEER2 / 13.0 EER2 Nominal Sizes: 1.5 to 5
Tons [5.3 to 17.6 kW] Cooling Capacities: 17.1 to 56.0 kBTU [5.0 to 16.4 kW]
Refrigerant Type: R-454B
- 16.0
*Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR®. Ask your Contractor for details or visit www.energystar.gov.
FORM NO. ARR-347
Table of Contents SA15AY
Table of Contents
Features & Benefits …………………………………………………………3 Model Number Identification
…………………………………………….4 General Data/Electrical Data …………………………………………….5
Accessories ……………………………………………………………………6 Unit Dimensions
……………………………………………………………..7 Clearances …………………………………………………………………….8 Refrigerant
Line Size Information ………………………………… 9-10 Performance Data
…………………………………………………………11 Smart Home Systems ……………………………………………………12 Limited
Warranty …………………………………………………………..16
2
Features and Benefits
· 7mm Condenser Copper Coil: Requires less refrigerant allowing for a smaller
and lighter footprint while enhancing reliability
· Expanded Valve Space: 3 in. 4 in. 5 in. service valve space provides a
minimum working area of 27-square inches for easier access
· Triple Service Access: 15 in. wide, industry leading access makes repairs
easier and faster
· Swept Wing Fan Technology1: Features quieter operation and improved unit
acoustics
· Designing for Sustainability with Low GWP: For 2025, the Environmental
Protection Agency (EPA) has set a global warming potential (GWP) limit of 700
for refrigerant used in
Features and Benefits SA15AY
heating and cooling systems. This new requirement will result in a 78%2 lower
GWP than previous-generation refrigerants — with only minimal changes to
system installation. For us, this is another step toward our continued
sustainability goal of reducing greenhouse gas emissions, while still
delivering an exceptional level of energy efficient, dependable comfort
· Refrigerant Detection System3: An integrated one-box, patented design
featuring the A2L sensor and mitigation board, offering easier commissioning
with a single component and simplified wiring configuration, compatibility
with any 24V thermostat application and system protection by automatically
pausing outdoor unit operation — if excess refrigerant is detected
1Does not apply to 1.5 and 2 ton models 2When comparing the GWP of R-454B to
R-410A refrigerant 3Factory or field installed in the furnace coil or air
handler and is applicable to the complete heating and cooling system featuring
Low GWP Refrigerant (A2L)
3
Model Number Identification SA15AY
Air Conditioners
S
A
15
A
Y
18
A
J
1
N
A
A40
Brand Product Category
SEER2
Region Refrigerant Capacity BTU/HR
Major Series
Voltage
Type
Controls
Minor Series
Option
S – Russell® A – Air Conditioners By Rheem
15 – 15.2 SEER2 A – All Regions Y – R-454B
18 – 18,000 [5.28 kW] 24 – 24,000 [7.03 kW] 30 – 30,000 [8.79 kW] 36 – 36,000 [10.55 kW] 42 – 42,000 [12.31 kW] 48 – 48,000 [14.07 kW] 60 – 60,000 [17.58 kW]
A – 1st Design
J – 208/230/1/60
1 – 1-Stage N – Non-Communicating A – 1st Design
A40 – Vertical Louvers A41 – Vertical Louvers
W/HLPC LHP – w/ HLPC
[ ] Designates Metric Conversions
SA15AY18AJ1NAA40 SA15AY18AJ1NAA41 SA15AY18AJ1NALHP SA15AY24AJ1NAA40 SA15AY24AJ1NAA41 SA15AY24AJ1NA SA15AY24AJ1NALHP SA15AY30AJ1NAA40 SA15AY30AJ1NAA41
Available Models SA15AY30AJ1NA SA15AY30AJ1NALHP SA15AY36AJ1NAA40 SA15AY36AJ1NAA41 SA15AY36AJ1NA SA15AY36AJ1NALHP SA15AY42AJ1NAA40 SA15AY42AJ1NAA41 SA15AY42AJ1NA
SA15AY42AJ1NALHP SA15AY48AJ1NAA40 SA15AY48AJ1NAA41 SA15AY48AJ1NA SA15AY48AJ1NALHP SA15AY60AJ1NAA40 SA15AY60AJ1NAA41 SA15AY60AJ1NA SA15AY60AJ1NALHP
Standard Equipment
R-454B Refrigerant Scroll Compressor Field Installed Filter Drier Front
Seating Service Valves Internal Pressure Relief Valve Internal Thermal
Overload Long Line capability Low Ambient capability with Kit 3-4-5 Expanded
Valve Space Composite Basepan 2 Screw Control Box Access No fasteners to
remove along bottom Optimized Venturi Airflow Powder coated paint Rust
resistant screws QR code External gauge ports Service trays
4
General Data/Electrical Data SA15AY
General Data
MODEL NO. Nominal Tonnage Valve Connections
Liquid Line O.D. in. Suction Line O.D. in. Refrigerant (R-454B) furnished
oz.¹ Compressor Type Outdoor Coil Net face area Outer Coil Net face area
Inner Coil
Tube diameter in. Number of rows Fins per inch
Outdoor Fan Diameter in.
Number of blades Motor hp CFM RPM Watts
Shipping weight lbs. Operating weight lbs.
SA15AY18 1.5
3/8 3/4 92
10.9 10.5 0.276
2 24
20 2 1/7 2156 1075 152 151 144
SA15AY24 2.0
3/8 3/4 112
13.3 12.9 0.276
2 24
24 2 1/6 2723 825 161 185 178
SA15AY30 2.5
3/8 3/4 92
14.3 13.9 0.276
2 24
24 2 1/6 2813 825 170 197 190
SA15AY36 3.0
3/8 3/4 104 Scroll
16.4 15.9 0.276
2 24
24 2 1/6 2944 825 174 217 210
SA15AY42 3.5
3/8 7/8 142
19.5 18.8 0.276
2 24
24 3 1/5 3431 850 225 259 252
SA15AY48 4.0
3/8 7/8 142
19.5 18.8 0.276
2 24
24 3 1/5 3606 850 251 250 243
SA15AY60 5.0
3/8 7/8 192
27.9 27.1 0.276
2 24
26 3 1/5 4169 850 245 273 266
Electrical Data
Line Voltage Data (Volts-Phase-Hz) Maximum overcurrent protection (amps)²
Minimum circuit ampacity³ Compressor
Rated load amps Locked rotor amps Condenser Fan Motor
Full load amps Locked rotor amps
208/230-1-60 15 12
8 42
0.8 1.5
208/230-1-60 20 13
9 59
0.8 1.7
208/230-1-60 25 17
13 76
0.8 1.7
208/230-1-60 30 18
14 75
0.8 1.7
208/230-1-60 30 20
15 109
1.0 2.6
208/230-1-60 50 30
22 126
1.0 2.6
208/230-1-60 50 31
24 157
1.0 2.6
¹Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the installation instructions for information about set length and additional refrigerant charge required. ²HACR type circuit breaker of fuse. ³Refer to National Electrical Code manual to determine wire, fuse and disconnect size requirements.
5
Accessories SA15AY
Accessories
Model No.
Compressor crankcase heater (with temperature thermostat)
SA15AY18 44-101884-08
SA15AY24 44-101884-08
SA15AY30 44-101884-08
SA15AY36
SA15AY42
SA15AY48
SA15AY60
44-101884-08 44-103663-16* 44-103663-16 44-103663-16**
Compressor crankcase heater (without temperature thermostat)
44-17402-44
44-17402-44
44-17402-44
44-17402-44
44-17402-45
44-17402-45
44-17402-45
Low ambient control
RXAD-A08
RXAD-A08
RXAD-A08
RXAD-A08
RXAD-A08
RXAD-A08
RXAD-A08
Compressor sound cover
68-23427-26
68-23427-26
68-23427-26
68-23427-26
68-23427-25
68-23427-25
68-23427-25
Compressor hard start kit
SK-A1
SK-A1
SK-A1
SK-A1
SK-A1
SK-A1
SK-A1
Compressor time delay
RXMD-B01
RXMD-B01
RXMD-B01
RXMD-B01
RXMD-B01
RXMD-B01
RXMD-B01
Low pressure control
RXAC-A10
RXAC-A10
RXAC-A10
RXAC-A10
RXAC-A10
RXAC-A10
RXAC-A10
High pressure control
RXAB-A08
RXAB-A08
RXAB-A08
RXAB-A08
RXAB-A08
RXAB-A08
RXAB-A08
Liquid Line Solenoid (24 VAC, 50/60 Hz)
Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC
Solenoid Coil 61-AMG24V
61-AMG24V
61-AMG24V
61-AMG24V
61-AMG24V
61-AMG24V
61-AMG24V
Liquid Line Solenoid
Solenoid Valve 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC 200RD2T3TVLC
(120/240 VAC, 50/60 Hz) Solenoid Coil 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V 61-AMG120/240V
SA15AY42 models with LG come with 44-101884-08 factory-installed. SA15AY60 models come with 44-103663-16 factory-installed.
Maximum System Charge Values SA15AY
Maximum System Charge Values SA15AY
Model No.
Charge Limit Without Crankcase Heater
Copeland
LG
SA15AY18
SA15AY24 SA15AY30
9.6 lbs [4.4kg]
8.4 lbs [3.8 kg]
SA15AY36
SA15AY42*
SA15AY48 SA15AY60*
12 lbs [5.4kg]
11.9 lbs [5.4 kg]
*SA15AY42 models with LG compressors and SA15AY60 ton models have factory-installed crankcase heaters.
Weighted Sound Power Level (dBA)
Unit Size –
Standard
Voltage, Series
Rating (dBA)
125
SA15AY18
71
48
SA15AY24
69
45
SA15AY30
71
45
SA15AY36
72
45
SA15AY42
73
47
SA15AY48
74
45
SA15AY60
76
43
NOTE: Tested in accordance with AHRI Standard 270-08 (not listed in AHRI)
TYPICAL OCTAVE BAND SPECTRUM (dBA without tone adjustment)
250
500
1000
2000
4000
56
62
61
57
54
54
59
58
56
51
55
60
59
57
54
53
60
61
59
56
55
64
62
59
55
56
64
63
61
57
60
67
66
63
59
8000 46 46 46 48 48 51 53
6
Unit Dimensions
Model No.
SA15AY18 SA15AY24 SA15AY30 SA15AY36 SA15AY42 SA15AY48 SA15AY60
H (Height)
Inches
mm
25.00
635
25.00
635
27.00
686
31.00
787
35.00
889
35.00
889
45.00
1143
OPERATING
L (Length)
Inches
mm
29.75
756
33.75
857
33.75
857
33.75
857
33.75
857
33.75
857
35.75
908
W (Width)
Inches
mm
29.75
756
33.75
857
33.75
857
33.75
857
33.75
857
33.75
857
35.75
908
H (Height)
Inches
mm
26.50
673
26.50
673
28.50
724
32.50
826
36.50
927
36.50
927
46.50
1181
SHIPPING
L (Length)
Inches
mm
32.38
822
36.38
924
36.38
924
36.38
924
36.38
924
36.38
924
38.38
975
Unit Dimensions SA15AY
W (Width)
Inches
mm
32.38
822
36.38
924
36.38
924
36.38
924
36.38
924
36.38
924
38.38
975
ALLOW OVER HANG CLEARANCE OF
60 [1524 mm] MIN.
A I R
D
I
W
S
L
C
H
A
R
G
E
H
AIR INLET GRILLE ALLOW 6 [152 mm] MIN. CLEARANCE ALL SIDE 12 [305 mm]
RECOMMENDED
[ ] Designates Metric Conversions
SERVICE PANELS/ INLET CONNECTIONS / HIGH & LOW VOLTAGE
ACCESS ALLOW 24 [610 mm] MIN.
CLEARANCE
ST-A1226-24-00
7
Clearances SA15AY
8
WALL
CLEARANCES
WALL
6 (152.4)
24 (609.6)
Service
12 (304.8)
6 (152.4)
WALL
24 (609.6) Service
12 (304.8)
6 (152.4)
12 (304.8)
24 (609.6)
Service
WALL
24 (609.6) Service
24 (609.6)
Service
18 (457.2)
24 (609.6)
24 recommended 6 minimum
24 (609.6)
24 recommended 6 minimum
NOTE: NUMBERS IN () = mm
IMPORTANT: When installing multiple units in an alcove, roof well or partially
enclosed area, ensure there is adequate ventillation to prevent re-circulation
of discharge air.
ST-A1225-01-00
Refrigerant Line Size Information SA15AY
Refrigerant Line Size Information
15.2 SEER2 AC R-454B
Allowable Allowable
Unit Size Liquid
Suction
0-25
Line Size Line Size
Equivalent Length (Feet)
26-50
51-75 76-100 101-125 126-150 151-175 176-200 201-225
Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) */ Capacity Multiplier
1/4″
5/8″
25/1
50/0.99 61/0.99 41/0.98 21/0.98
5/16″
5/8″
25/1
50/0.99 75/0.99 100/0.98 98/0.98
3/8″ 1.5 Ton
1/4″
5/8″
25/1
50/0.99 75/0.99 100/0.98 117/0.98
3/4″
25/1
50/1
61/1
41/0.99 21/0.99
5/16″
3/4″
25/1
50/1
75/1 100/0.99 98/0.99
3/8″
3/4″
25/1
50/1
75/1 100/0.99 117/0.99
1/4″
5/8″
25/1
50/0.99 25/0.98 0/0.98
0/0.98
5/16″
5/8″
25/1
50/0.99 75/0.98 88/0.98 79/0.98
3/8″ 2 Ton
1/4″
5/8″
25/1
50/0.99 75/0.98 100/0.98 109/0.98
3/4″
25/1
50/1
25/0.99 0/0.99
0/0.99
5/16″
3/4″
25/1
50/1
75/0.99 88/0.99 79/0.99
3/8″
3/4″
25/1
50/1
75/0.99 100/0.99 109/0.99
5/16″
5/8″
25/0.99 50/0.98 75/0.98 69/0.97 56/0.98
2.5 Ton
3/8″ 5/16″
5/8″
25/0.99 50/0.98 75/0.98 100/0.97 101/0.98
3/4″
25/1
50/0.99 75/0.99 69/0.98 56/0.98
3/8″
3/4″
25/1
50/0.99 75/0.99 100/0.98 101/0.98
5/16″
5/8″
25/0.99 50/0.98 65/0.97 47/0.97 28/0.94
3/8″
5/8″
25/0.99 50/0.98 75/0.97 97/0.97 91/0.94
5/16″
3/4″
25/1
50/0.99 65/0.98 47/0.99 28/0.98
3/8″ 3 Ton
1/2″
3/4″
25/1
50/0.99 75/0.98 97/0.99 91/0.98
3/4″
25/1
50/0.99 75/0.98 100/0.99 118/0.98
5/16″
7/8″
25/1
50/1
65/0.99 47/0.99 28/0.99
3/8″
7/8″
25/1
50/1
75/0.99 97/0.99 91/0.99
1/2″
7/8″
25/1
50/1
75/0.99 100/0.99 118/0.99
3/8″
3/4″
25/0.99 50/0.99 75/0.99 88/0.98 80/0.97
1/2″ 3.5 Ton
3/8″
3/4″
25/0.99 50/0.99 75/0.99 100/0.98 116/0.97
7/8″
25/1
50/0.99 75/0.99 88/0.99 80/0.98
1/2″
7/8″
25/1
50/0.99 75/0.99 100/0.99 116/0.98
3/8″
3/4″
25/0.99 50/0.98 75/0.98 78/0.97 68/0.96
1/2″ 4 Ton
3/8″
3/4″
25/0.99 50/0.98 75/0.98 100/0.97 113/0.96
7/8″
25/1
50/0.99 75/0.99 78/0.98 68/0.99
1/2″
7/8″
25/1
50/0.99 75/0.99 100/0.98 113/0.99
3/8″
3/4″
25/0.99 50/0.98 70/0.97 54/0.97 38/0.94
1/2″
3/4″
25/0.99 50/0.98 75/0.97 100/0.97 107/0.94
3/8″ 5 Ton
1/2″
7/8″
25/0.99 50/0.99 70/0.98 54/0.98 38/0.98
7/8″
25/0.99 50/0.99 75/0.98 100/0.98 107/0.98
3/8″
1-1/8″
25/1
50/1
70/1
54/0.99 38/0.99
1/2″
1-1/8″
25/1
50/1
75/1 100/0.99 107/0.99
NOTES: Maximum Equivalent Line Length may not exceed 250′. Maximum Actual Line Length may not exceed 200′. Light Grey shaded areas are considered long line and may require accessories as recommended in Long Line Set Guide. DO NOT use suction line traps in the suction riser as this adds additional unwanted pressure drop in the system.
1/0.98 93/0.98 115/0.98 1/0.99 93/0.99 115/0.99 0/0.97 70/0.97 106/0.97 0/0.98 70/0.98 106/0.98 43/0.96 96/0.96 43/0.99 96/0.99 11/0.93 85/0.93 11/0.98 85/0.98 117/0.98 11/0.98 85/0.98 117/0.98 72/0.96 114/0.96 72/0.99 114/0.99 57/0.97 111/0.97 57/0.98 111/0.98 22/0.93 104/0.93 22/0.97 104/0.97 22/0.99 104/0.99
0/0.98 87/0.98 114/0.98 0/0.99 87/0.99 114/0.99 0/0.96 62/0.96 103/0.96 0/0.98 62/0.98 103/0.98 30/0.94 92/0.94 30/0.98 92/0.98 0/0.92 78/0.92 0/0.97 78/0.97 115/0.97 0/0.98 78/0.98 115/0.98 64/0.98 112/0.98 64/0.99 112/0.99 46/0.95 109/0.95 46/0.98 109/0.98 6/0.92 101/0.92 6/0.96 101/0.96 6/0.99 101/0.99
0/0.98 82/0.98 112/0.98 0/0.99 82/0.99 112/0.99 0/0.97 53/0.97 100/0.97 0/0.99
53/0.99 100/0.99 17/0.93 87/0.93 17/0.98 87/0.98 0/0.91 72/0.91 0/0.96 72/0.96
115/0.96 0/0.99 72/0.99 115/0.99 55/0.96 111/0.96 55/0.98 111/0.98 36/0.94
107/0.94 36/0.98 107/0.98
0/0.9 97/0.9 0/0.98 97/0.98 0/0.99 97/0.99
0/0.97 78/0.97 111/0.97 0/0.99 78/0.99 111/0.99 0/0.96 46/0.96 97/0.96 0/0.99 46/0.99 97/0.99 6/0.92 83/0.92 6/0.97 83/0.97 0/0.9 66/0.9 0/0.96 66/0.96 114/0.96 0/0.99 66/0.99 114/0.99 47/0.95 109/0.95 47/0.98 109/0.98 25/0.93 105/0.93 25/0.97 105/0.97 0/0.89 95/0.89 0/0.97 95/0.97 0/0.99 95/0.99
226-250
0/0.97 75/0.97 110/0.97 0/0.98 75/0.98 110/0.98 0/0.95 40/0.95 94/0.95 0/0.98
40/0.98 94/0.98 0/0.93 78/0.93 0/0.97 78/0.97 0/0.9 60/0.9 0/0.98 60/0.98
112/0.98 0/0.99 60/0.99 112/0.99 39/0.95 108/0.95 39/0.98 108/0.98 15/0.93
104/0.93 15/0.97 104/0.97 0/0.89 93/0.89 0/0.96 93/0.96 0/0.98 93/0.98
[ ] Designates Metric Conversions
9
Refrigerant Line Size Information SA15AY
Refrigerant Line Size Information (Con’t.)
15.2 SEER2 AC R-454B
Unit Size
Allowable Liquid
Line Size
Allowable Suction Line Size
0-7.6
Equivalent Length (Meters) 7.9-15.2 15.5-22.9 23.2-30.5 30.8-38.1 38.4-45.7
46-53.3 53.6-61 61.3-68.6 68.9-76.2
Maximum Vertical Rise (Outdoor Unit Below Indoor Unit) */ Capacity Multiplier
1/4″
5/8″
8/1
15/0.99 19/0.99 12/0.98 6/0.98
5/16″
5/8″
8/1
15/0.99 23/0.99 30/0.98 30/0.98
3/8″
5/8″
8/1
15/0.99 23/0.99 30/0.98 36/0.98
1.5 Ton
1/4″
3/4″
8/1
15/1
19/1
12/0.99 6/0.99
5/16″
3/4″
8/1
15/1
23/1
30/0.99 30/0.99
3/8″
3/4″
8/1
15/1
23/1
30/0.99 36/0.99
1/4″
5/8″
8/1
15/0.99 8/0.98
0/0.98
0/0.98
5/16″
5/8″
8/1
15/0.99 23/0.98 27/0.98 24/0.98
3/8″
5/8″
8/1
15/0.99 23/0.98 30/0.98 33/0.98
2 Ton
1/4″
3/4″
8/1
15/1
8/0.99
0/0.99
0/0.99
5/16″
3/4″
8/1
15/1
23/0.99 27/0.99 24/0.99
3/8″
3/4″
8/1
15/1
23/0.99 30/0.99 33/0.99
5/16″
5/8″
8/0.99 15/0.98 23/0.98 21/0.97 17/0.98
2.5 Ton
3/8″ 5/16″
5/8″
8/0.99 15/0.98 23/0.98 30/0.97 31/0.98
3/4″
8/1
15/0.99 23/0.99 21/0.98 17/0.98
3/8″
3/4″
8/1
15/0.99 23/0.99 30/0.98 31/0.98
5/16″
5/8″
8/0.99 15/0.98 20/0.97 14/0.97 9/0.94
3/8″
5/8″
8/0.99 15/0.98 23/0.97 30/0.97 28/0.94
5/16″
3/4″
8/1
15/0.99 20/0.98 14/0.99 9/0.98
3/8″
3/4″
8/1
15/0.99 23/0.98 30/0.99 28/0.98
3 Ton
1/2″
3/4″
8/1
15/0.99 23/0.98 30/0.99 36/0.98
5/16″
7/8″
8/1
15/1
20/0.99 14/0.99 9/0.99
3/8″
7/8″
8/1
15/1
23/0.99 30/0.99 28/0.99
1/2″
7/8″
8/1
15/1
23/0.99 30/0.99 36/0.99
3/8″
3/4″
8/0.99 15/0.99 23/0.99 27/0.98 24/0.97
1/2″ 3.5 Ton
3/8″
3/4″
8/0.99 15/0.99 23/0.99 30/0.98 35/0.97
7/8″
8/1
15/0.99 23/0.99 27/0.99 24/0.98
1/2″
7/8″
8/1
15/0.99 23/0.99 30/0.99 35/0.98
3/8″
3/4″
8/0.99 15/0.98 23/0.98 24/0.97 21/0.96
1/2″ 4 Ton
3/8″
3/4″
8/0.99 15/0.98 23/0.98 30/0.97 34/0.96
7/8″
8/1
15/0.99 23/0.99 24/0.98 21/0.99
1/2″
7/8″
8/1
15/0.99 23/0.99 30/0.98 34/0.99
3/8″
3/4″
8/0.99 15/0.98 21/0.97 16/0.97 12/0.94
1/2″
3/4″
8/0.99 15/0.98 23/0.97 30/0.97 33/0.94
3/8″ 5 Ton
1/2″
7/8″
8/0.99 15/0.99 21/0.98 16/0.98 12/0.98
7/8″
8/0.99 15/0.99 23/0.98 30/0.98 33/0.98
3/8″
1-1/8″
8/1
15/1
21/1
16/0.99 12/0.99
1/2″
1-1/8″
8/1
15/1
23/1
30/0.99 33/0.99
NOTES: Maximum Equivalent Line Length may not exceed 76 meters. Maximum Actual Line Length may not exceed 61 meters. Light Grey shaded areas are considered long line and may require accessories as recommended in Long Line Set Guide. DO NOT use suction line traps in the suction riser as this adds additional unwanted pressure drop in the system.
0/0.98 28/0.98 35/0.98 0/0.99 28/0.99 35/0.99 0/0.97 21/0.97 32/0.97 0/0.98 21/0.98 32/0.98 13/0.96 29/0.96 13/0.99 29/0.99 3/0.93 26/0.93 3/0.98 26/0.98 36/0.98 3/0.98 26/0.98 36/0.98 22/0.96 35/0.96 22/0.99 35/0.99 17/0.97 34/0.97 17/0.98 34/0.98 7/0.93 32/0.93 7/0.97 32/0.97 7/0.99 32/0.99
0/0.98 27/0.98 35/0.98 0/0.99 27/0.99 35/0.99 0/0.96 19/0.96 31/0.96 0/0.98 19/0.98 31/0.98 9/0.94 28/0.94 9/0.98 28/0.98 0/0.92 24/0.92 0/0.97 24/0.97 35/0.97 0/0.98 24/0.98 35/0.98 20/0.98 34/0.98 20/0.99 34/0.99 14/0.95 33/0.95 14/0.98 33/0.98 2/0.92 31/0.92 2/0.96 31/0.96 2/0.99 31/0.99
0/0.98 25/0.98 34/0.98 0/0.99 25/0.99 34/0.99 0/0.97 16/0.97 30/0.97 0/0.99
16/0.99 30/0.99 5/0.93 27/0.93 5/0.98 27/0.98 0/0.91 22/0.91 0/0.96 22/0.96
35/0.96 0/0.99 22/0.99 35/0.99 17/0.96 34/0.96 17/0.98 34/0.98 11/0.94 33/0.94
11/0.98 33/0.98
0/0.9 30/0.9 0/0.98 30/0.98 0/0.99 30/0.99
0/0.97 24/0.97 34/0.97 0/0.99 24/0.99 34/0.99 0/0.96 14/0.96 30/0.96 0/0.99
14/0.99 30/0.99 2/0.92 25/0.92 2/0.97 25/0.97
0/0.9 20/0.9 0/0.96 20/0.96 35/0.96 0/0.99 20/0.99 35/0.99 14/0.95 33/0.95
14/0.98 33/0.98 8/0.93 32/0.93 8/0.97 32/0.97 0/0.89 29/0.89 0/0.97 29/0.97
0/0.99 29/0.99
0/0.97 23/0.97 34/0.97 0/0.98 23/0.98 34/0.98 0/0.95 12/0.95 29/0.95 0/0.98
12/0.98 29/0.98 0/0.93 24/0.93 0/0.97 24/0.97
0/0.9 18/0.9 0/0.98 18/0.98 34/0.98 0/0.99 18/0.99 34/0.99 12/0.95 33/0.95
12/0.98 33/0.98 5/0.93 32/0.93 5/0.97 32/0.97 0/0.89 28/0.89 0/0.96 28/0.96
0/0.98 28/0.98
10
Performance Data SA15AY
Performance Data @ AHRI Standard Conditions Cooling
Designated Tested Combination (DTC)
Outdoor Unit
Indoor Coil
Total Capacity BTU/H [kW]
Net Sensible BTU/H [kW]
Net Latent BTU/H [kW]
SEER2
EER2
Indoor CFM [L/s]
SA15AY18
TCFY2417STAN
17,100 [5.0]
13,100 [3.8]
4,000 [1.2]
14.3
11.7
1,600 [283.2]
SA15AY24
TCFY2417STAN
22,800 [6.7]
17,500 [5.1]
5,300 [1.6]
14.3
11.7
1,735 [346.9]
SA15AY30
TCFY3621MTAN
28,600 [8.4]
21,800 [6.4]
6,800 [2.0]
14.3
11.7
1,910 [429.5]
SA15AY36
TCFY3621MTAN
34,000 [10.0]
26,000 [7.6]
8,000 [2.3]
14.3
11.7
1,030 [486.1]
SA15AY42
TCFY4221STAA
40,000 [11.7]
30,700 [9.0]
9,300 [2.7]
14.3
11.7
1,300 [613.5]
SA15AY48
TCFY4821STAA
45,500 [13.3]
34,900 [10.2]
10,600 [3.1]
13.8
11.7
1,425 [672.5]
SA15AY60
TCFY6024STAN
56,000 [16.4]
42,900 [12.6]
13,100 [3.8]
13.8
11.7
1,575 [743.3]
NOTE: This data includes DTC (Designated Test Combination) ratings and is for reference purposes only. A full listing of official ratings and system match- ups, along with downloadable certificates, can be accessed from the AHRI website: www.ahridirectory.org.
[ ] Designates Metric Conversions
11
GENERAL TERMS OF LIMITED WARRANTY
Russell® By Rheem will furnish a replacement for any part of this product
which fails in normal use and service within the applicable period stated, in
accordance with the terms of the limited warranty.
For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate.
Conditional Parts (Registration Required)…………………………….. Ten (10) Years
Before proceeding with installation, refer to installation instructions
packaged with each model, as well as complying with all Federal, State,
Provincial, and Local codes, regulations, and practices.
© 2024 Rheem Manufacturing Company. Russell By Rheem trademarks owned by Rheem
Manufacturing Company. In keeping with its policy of continuous progress and
product improvement, Russell by Rheem reserves the right to make changes
without notice.
5600 Old Greenwood Road Fort Smith, Arkansas 72908 · www.russellbyrheem.com
PRINTED IN U.S.A. 6/24 QG FORM NO. ARR-347
References
- ahridirectory.org
- Homepage | ENERGY STAR
- Russell By Rheem – HVAC equipment made to deliver comfort you can count on
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>