The product is a soldering station with four models: WX 1, WX 2, WXD 2, and WXA 2. It is manufactured by Weller-Tools and available for purchase on their website. The product comes with a user manual that contains safety information, specified conditions of use, user groups, care and maintenance instructions, warranty details, technical data, and symbols.
Product Usage Instructions
- Read the user manual and safety guidelines carefully before using the product.
- Ensure that children and youths under the age of 16 do not use the device without supervision.
- Connect the device to a power source of 230 V / 110-120V.
- Select the appropriate model of the soldering station for your intended usage (WX 1, WX 2, WXD 2, or WXA 2).
- Adjust the airflow rate using the provided controls to achieve the desired level of performance.
- Turn the device on using the ON/OFF button and adjust the performance mode to suit your needs (WXHAP ON/OFF).
- Adjust the LCD contrast to your liking (10-100%).
- If necessary, use the robot output to connect the device to a robotic system.
- Use the post-activation du vide function (WXD 2 0 – 10 s) as needed.
- Set the standby time according to your preferences (1-999 min).
- Use the button lock function to prevent accidental changes to settings.
- Select your preferred language (EN, ES, FR, DE, IT, PT, NL, SV, DK, FI, GR, PL, HU, SK, SL, EE, LV, LT, BG, HR, RU).
- If you require additional assistance or have questions, consult the FAQ section or contact customer support.
Original instructions
What’s in the box
Overview
Diagram
Assembly
Standby Temperature 100 – 450 °C
200 – 850 °F
Standby Time
1 – 999 min
OFF time
1-999 min
Sensitivity
low
normal
high
WXHAP
Max. hot air duration
1-60 s
Perform. Mode
standard
soft
aggressive
WXHAP
Button lock ON / OFF
Process window 100 – 450 °C
200 – 850 °F
Language
Temperature units C/°F
Lock function 1-999
Touch tones on/off
ON / OFF
LCD-Contrast
10 – 60
LCD background brightness
10 – 100 %
Screen saver
ON / OFF
Robot output 100 – 450 °C
200 – 850 °F
WXD 2 Vacuum pre-feed
0 – 10 s
WXD 2
Vacuum run-on 0 – 10 s
Read these instructions and the safety guidelines carefully before starting up the unit and starting work.
Failure to observe the safety regulations results in a risk to life and limb.
Keep these instructions in a place that is accessible to all users. Please
adhere to the operating instructions of the connected devices.
Safety information
For safety reasons, children and youths under the age of 16, as well as per-
sons who are not familiar with these operating instructions, may not use the
device. Children should be supervised in order to ensure that they do not play
with the tool.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without super-
vision.
Keep other persons well away from your workplace. The work area is out of
bounds for children and unauthorised persons. Never allow other persons to
touch the soldering tool or cable.
WARNING: Electrical shock
Connecting the control unit incorrectly poses a risk of injury due to electric shock and can damage the device.
- Carefully read the attached safety information, the safety information accompanying these operating instructions as well as the operating instructions for your control unit before putting the control unit into operation and observe the safety precautions specified therein.
- Only connect WELLER tools.
If the device is faulty, active electrical conductors may be bare or the PE conductor may not be functional.
- Repairs must always be referred to a Weller-trained specialist.
- If the electrical tool‘s power supply cord is damaged, this must be replaced with a specially prefabricated power supply cord available through the customer service organisation.
Protect yourself against electric shocks. The handles on soldering tools with an antistatic design are conductive.
- Avoid touching earthed objects such as pipes, heaters, cookers and refrigerators.
- Do not use the soldering tool in a damp or wet environment.
- Never work on voltage-carrying parts.
WARNING: Risk of burns
Risk of burns from the soldering tool while the control unit is operating. Tools may still be hot long after they have been switched off.
- Always place the soldering tool in the safety rest while not in use. Make sure the safety holder is stable.
- Only connect the vacuum and hot air at the designated points.
- Do not direct hot air soldering tools at people or inflammable objects.
- Only replace solder tips when cold
Risk of burning through liquid solder. Protect yourself against solder splashes.
- Wear appropriate protective clothing to protect yourself against burns. Protect your eyes by wearing eye protectors.
- When working with adhesives, special attention must be paid to the warning information provided by the adhesive manufacturer.
Store your soldering tool in a safe place. When not in use, units and tools should be stored in a dry, high or locked area out of the reach of children. Make sure that unused soldering tools are free of voltage and de-pressurised.
WARNING: Fire hazard
Covering the soldering iron or the safety holder poses a fire hazard. Always keep objects well away from the soldering iron and safety holder.
- Always keep objects well away from the soldering iron and safety holder.
- Keep all combustible objects, liquids or gases well away from the hot soldering tool.
The mains cable must only be plugged into the mains socket or adapter approved
for this purpose. Check to see if the mains voltage matches the ratings on the
nameplate. Make sure the machine is switched off before plugging in.
Do not use the cable for purposes other than those for which it is
intended.Never carry the unit by the cable. Do not use the cable to pull the
plug out of the socket. Protect the cable against heat, oil and sharp edges..
Be alert. Pay attention to what you are doing. Be smart when using the unit.
Do not use the soldering tool if you are having difficulty concentrating.
Avoid abnormal posture. Arrange your work station in an ergonomically correct
way. Avoid bad posture when using the unit, as this can lead to postural
problems.
The soldering tool must be operated only in perfect technical working order.
Safety devices must not be deactivated.
Faults and defects must be repaired immediately. Before using the unit / tool,
safety devices must be carefully checked to make sure that they are
functioning properly and in the manner intended. Check that moving parts are
func-tioning properly and are not sticking, and whether parts are damaged. All
parts must be correctly fitted and must satisfy all the requirements necessary
to guarantee troublefree operation of the unit.
Use the correct tool. Use only accessories or auxiliary de-vices which are
included in the list of accessories or appro-ved for use by the manufacturer.
Use WELLER accessories or auxiliary devices on original WELLER equipment only.
The use of other tools and other accessories can cause injury.
Secure the tool. Use clamping fixtures to hold the workpiece.
Use a solder fume extraction unit. If appliances for connecting solder fume
extraction units are available, ensure that they are connected and used
properly.
Specified Conditions Of Use
Supply unit for WELLER WX soldering tools. Use the soldering station /
desoldering station / hot air station exclusively for the purpose indicated in
the operating instructions of soldering and desoldering under the conditions
specified herein.
WARNING
Flammable gases and liquids may not be extracted.
The device may only be used with correctly fitted and suitable filter
cartridges.
Replace filter cartridges when full.
This device may only be used at room temperature and indoors. Protect against moisture and direct sunlight.
User groups
Due to differing degrees of risk and potential hazards, sever-al work steps
may only be performed by trained experts.
Work step | User groups |
---|---|
Default soldering parameters | Specialist personnel with technical training |
Replacing electrical repla- cement parts | Electricians |
Default maintenance intervals | Safety expert |
Operation Filter change | Non-specialists |
Operation Filter change
Replacing electrical replacement parts
| Technical trainees under the guidance and supervision of a trained expert
Care and maintenance
WARNING
Before doing any work on the machine, pull the plug out of the socket. Leave
the unit to cool down.
Clean the operator panel, if dirty, using a suitable cleaning cloth.
Seal ports which are not in use with covering caps.
Check all connected cables and hoses on a regular basis. If power tools are
damaged, they must be immediately removed from use.
WARNING: Risk of burns
- Only replace solder tips when cold
- Replace and clean suction nozzles only when hot and using the suitable tool
- Only replace hot air nozzles using the suitable tool
- Only clean or replace solder collection tubes when cold
Filter change
Regularly check the main filter for vacuum, and replace it if necessary.
Contaminated filters must be treated as special waste. Dispose of replaced
equipment parts, filters or old devices in accordance with the rules and
regulations applicable in your country. Wear suitable protective gear.
Warning!
Working without a filter can result in irreparable damage to the vacuum unit.
- Check before starting soldering whether a main filter is inserted.
Repairs must always be referred to a Weller-trained specialist.
Use original replacement parts only.
Warranty
Claims by the buyer for physical defects are time-barred after a period of one
year from delivery to the buyer. This does not apply to claims by the buyer
for indemnification in accordance with §§ 478, 479 BGB (German Federal Law
Gazette).
We shall only be liable for claims arising from a warranty furnished by us if
the quality or durability warranty has been furnished by use in writing and
using the term „Warranty“.
The warranty shall be void if damage is due to improper use and if the device
has been tampered with by unauthorised persons.
For more information please visit: www.weller-tools.com.
Symbols
Caution!
Warning! Risk of burns!
Read the operating instructions!
Before performing work of any kind on the unit, always disconnect the power plug from the socket.
ESD-compatible design and ESD-compatible workstation
Equipotential bonding
Soldering
Desoldering
Hot air
CE: CE mark of conformity
UKCA: British Conformity Mark
Fuse
Safety transformer
Disposal
Do not dispose of electric tools together with household waste material! In
observance of European Directive 2012/19/EU on waste electrical and electronic
equipment and its implementation in accordance with national law, electric
tools that have reached the end of their life must be collected separately and
returned to an environ-mentally compatible recycling facility.
Disposal – UK
Do not dispose of electric tools together with household waste material! In
observance of British Directive 2013 No. 3113 on waste electrical and
electronic equipment and its implementation in accordance with national law,
electric tools that have reached the end of their life must be collected
separately and returned to an environ-mentally compatible recycling facility.
Technical Data
| soldering station WX 1| soldering station WX
2| desoldering station WXD 2| Hot air station
WXA 2
---|---|---|---|---
Dimensions L x W x H| 170 x 151 x 130 mm
6,69 x 5,94 x 5,12 inch
Weight| ca. 3,2 kg| ca. 3,2 kg| ca. 3,8 kg| ca. 3,8 kg
Mains supply voltage| 230 V, 50 Hz| / 120 V, 60 Hz| / 100 V 50/60 Hz|
Power consumption| 200 W| 200 W (255 W)| 200 W (255 W)| 200 W (255 W)
Safety class| I, antistatic housing III, Soldering tool
Fuse| T2 A (230 V)
T4 A (120 V)
Temperature range Tool dependent| 100 – 450°C
200 – 850°F| (550°C) (999°F)| |
Temperature accuracy| ± 9 °C / ± 17 °F
Temperature stability| ± 2 °C / ± 4 °F
Air consumption| –| 35 l / min, max vacu- um 55 kPA (8 psi)| –
Compressed air connection| –| Compressed air hose outer diameter 6 mm (0,24“)|
Compressed air hose outer diameter 6 mm (0,24“)
Compressed air| –| Inlet pressure 400 – 600 kPA
(58-87 psi); oil-free, dry compressed air| Inlet pressure 400 – 600 kPA (58-87
psi) oil free, dry compressed air or nitrogen (N2) *
Air flow:| –| approx. 0-18 l/ min at 6 bar
- WXA 2: Nitrogen N2 reduces oxidation and flux remains active for longer. We recommend the nitrogen N2 that is available in steel bottles. The bottle must be equipped with a 0-10 bar pressure reducer.
Subject to technical alterations and amendments.
Product Registration
www.weller-tools.com/registration
GERMANY
Weller Tools GmbH
Carl-Benz-Straße 2 74354 Besigheim
Tel: +49 (0)7143 580-0
Fax: +49 (0)7143 580-108
USA
Apex Tool Group, LLC.
Weller Professional Tools Division 1000 Lufkin Road
Apex, NC 27539
Tel: +1 919-362-8381
Email: info@weller-tools.com
CHINA
Apex Tool Group
Room 302A, NO 177 Bibo Road Shanghai, 201202
Tel: +86 (21) 60880288
Fax: +86 (21) 60880289
GREAT BRITAIN
Apex tool Group (UK Operations)
Limited
Piccadilly, Tamworth
Staffordshire B78 2ER
Website: www.weller-tools.com
© 2021, Apex Tool Group, LLC.
Weller® is a registered Trademark and registered Design of Apex Tool Group,
LLC.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>