Product Info
Working Temperature
Remote Controller Buttons
Power Options
Caution
- The power supply is AC supply.
- Please confirm the rated voltage and frequency according to the nameplate when using it.
- One motor cannot be connected to two switches or external receivers at the same time.
- Two motors cannot be connected in parallel to the same switch or external receiver.
- The motor cannot be immersed in liquid for use.
- Please do not use heavy objects or sharp objects to damage the motor.
- Do not lift the motor by grabbing and pulling the power wire.
Instructions
Upper and Lower limits Setting
Upper limit
Lower limit
Note: Use remote controller to operate the motor if an external receiver is connected. If external switch is connected, operate the motor directly by the switch. When motor is not working, do not turn the hole with hexdriver.
Troubleshooting
Fault | Cause | Solution |
---|---|---|
The motor runs only towards in one directionafter powering on | Inside limit | |
switch of motor doesn’t open | Turn the crown and driving adaptor in the |
reverse direction
The motor does not run or start slowly| 1.Low voltage2.Wrong wire connection
3.Overloading4.Wrong installation| 1.Adjust the voltage to rated data2.Correct
the wire connection 3.Put the suitable weight for roller shade4.Reinstall the
tubular motor
The motor suddenly stop| The motr has exceeded termal overheat protection (4
minutes)| Wait for the motor to cool down for approximately 20 minutes
The motor makes a strange noise when it runs| 1.The crown and drive adapter
are not well adapterd to tube2•The driving tube is too long, cused the
brackets are too tightly| 1.Change correct size crown and drive adapter2.If
idler is active, make driving tube shorter toavoid the tight status