HUEDA™-Multi Zone LED Color Controller
Installation Guide
BEFORE YOU BEGIN, READ ALL WARNINGS AND INSTALLATION INSTRUCTIONS.
SAFETY & WARNINGS
-
Securely mount the Hueda™ Controller
-
This product is intended to be installed and serviced by a qualified licensed electrician. Install in accordance with the National Electric Code, and local regulations. Only power with a regulated (listed) constant voltage Class 2 power supply (12-24V DC Max). Failure to use a Class 2 power supply may cause fire or serious injury and will void the limited warranty. Never
use this product with dimmable or magnetic dimmable power source(driver) -
Ensure applicable wire is installed between driver, fixture and any controls in between. When choosing wire, factor in voltage drop, amperage rating and type (in-wall rated, Plenum rated, wet location rated, etc.). Inadequate wire installation could overheat wires and cause fire.
-
This product is rated for indoor installation and only for dry locations. Do not install in washrooms or areas near water (or the possibility of in the future).
-
Do not modify this product beyond the instructions in this guide or the limited warranty will be voided.
-
Wiring diagrams in this installation guide for basic installations. Please carefully review your installation before proceeding with a qualified electrician familiar with low voltage wiring.
-
Never install the HUEDA™ Controller in with other high voltage Junction Box as there is a risk of shock hazzard! National Electric Code requires electrical conductors to be separated by a barrier within the box or in a separate box!. Install only in the provided Junction box.
IMPORTANT NOTE
- Install Hueda DMX controller in a separate box rated for Low voltage use. NEC codes requires conductors shall not be placed in any raceway, compartment, outlet box, junction box, or similar fitting with conductors of electric light or power.
WIRE ENDS:
WIRE 6-8MM (0.25-0.30”)
Exposed wire should not be more than 6- 8 mm long & solder tip (tinned). Do
not allow Wires to cross and insure all exposed wire is fully inserted into
the screw terminals. Hand tighten screw terminals. Use 24 to 18 AWG gauge wire
for output terminals.
INCLUDED ITEMS IN BOX
- CAT5 Wire
- Instructions
REMOTE OPERATION
- The DMX controller can also be con also be controlled remotely via wi-fi with a compatible(iOS versions > 8.0) iOS tablet or mobile device using our application “HUEDA”.
- Please see our HUEDA™ web page for application instructions.
OPERATION OVERVIEW
INSTALLATION OVERVIEW
Install in accordance with the NEC and local regulations.
- Turn power OFF at main circuit breaker and verify the power is off.
- Determine an accessible location for a compatible low voltage driver to be installed between the main breaker and DMX controller. Determine a location to install additional accessories such as DMX decoders, fixtures etc. Ensure applicable wire is installed between all components. When choosing wire, factor in voltage drop, amp rating and type to prevent fire or electric shock.
- Remove the existing wall plate and switch. Pull switch from identify wires and disconnect from switch.
- Remove existing switch box from wall and install the included DMX controller switch box. Additional tools may be required to fit DMX controller switch box in the wall.
- Make wiring connections. See ‘Wiring Connections’ and ‘Mounting Diagram’ for additional information.
- Replace wiring back into switch box. Mount and align DMX decoders/fixtures. See ‘Setting the DMX Address’.
SETTING THE DMX ADDRESS
Please refer DMX Receiver instructions for setting the DMX address
WIRING CONNECTIONS
DO NOT connect directly to 120VAC.
See ‘System Diagram for a general system design. MOUNTING WARNING!!!
Never install the HUEDA™ Controller in with other high voltage Junction Box as
there is a risk of shock hazzard!
National Electric Code requires electrical conductors to be separated by a
barrier within the box or in a separate box!. Install only in the provided
Junction box
PINOUT CONNECTION GUIDE
The following diagrams/tables indicate the appropriate connections for
patching your own CAT5/RJ45, and XLR-3 splice cables. These diagrams are for
general reference and may slightly differ between different cable
manufacturers.
RJ45 568B Connection Pinout
RJ45 568B Pinout Table
Pin No.| Wire Color| Function
1| White/Orange| Data +
2| Orange| Data –
3| White/Green| None
4| Blue| None
5| White/Blue| None
6| Green| None
7| White/Brown| May be used as 2nd ground
8| Brown| Ground
XLR-3 Connection Pinout
XLR-3 Pinout Table
Pin No.| Function
1| Ground
2| Data –
3| Data +
DYNAMIC MODE CHART
The Dynamic Mode tool plays factory-programmed scenes. Choose up to 10 different scenes. Short press switches/pauses the mode. Long press adjusts speed of the dynamic mode
Mode Description
1| Full Color Fade #1
2| Reverse Rainbow Fade
3| Random Full Color Fade
4| 7 Color Jump
5| RGB Fade In / Fade Out
6| RGB Fade In to Off
7| RGB On to Fade Out
8| RGB Jump
9| Full Color Fade #2
10| Pastel Color Fade In / Fade Out
TROUBLESHOOTING
For thorough troubleshooting of LED strip light and fixtures, see LED fixture
installation guides.
LED fixtures not responding to touch
- Ensure the blue indicator light is on by pressing ‘Power Button’.
- Ensure the appropriate zone number was pressed prior to controlling the DMX decoder/fixture. For example, if you know the fixture is addressed to zone 1, press 1 prior to controlling.
- Ensure the individual zone has not been turned off. Pressing zones 1-3 will turn the specific zone ON/OFF. Additionally, long pressing R, G, B, W will increase/decrease individual brightness and tapping will turn R, G, B, W ON/OFF.
- Ensure the DMX decoder/fixture is addressed properly. For example, address ‘001’ will respond to zone 1 of the controller.
- See ‘Setting the DMX Address’ on page-2 for additional addressing information.
LED fixture responding incorrectly
- Ensure all wiring connections are correct. Reversing the Data + and Data – will cause lights to fiicker and not respond to controller.
- Power connections of all components (drivers, DMX decoders/fixtures, DMX controller).
- DMX Data connections -see ‘Pinout Connection Guide’ and ‘System Diagram’ for Rj45 hard-wiring connections.
- DMX decoder PWM output connections -see ‘System Wiring Diagram for CH 1-4 connections
SCAN QR CODE TO DOWNLOAD HUEDA™ APPLICATION
Download HUEDA App From IOS App Storehttps://itunes.apple.com/ca/app/hueda/id1033321775?mt=8
FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT
- This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
- Note: The manufactures is not responsible for any radio or tv interference caused by unauthorized modifications to this equipment. Such modifications will void the user’s authority to operate the equipment and warranty.
SYSTEM WIRING DIAGRAM
The following wiring diagram is as an example system connectivity. CAT5 (RJ45
connections) cables are the most effective solution for transmitting DMX-512
signals. XLR-3 cables may also be installed but require an additional adapter
for connecting to DMX decoders (LT-840). With DMX decoders like LT-840, it is
possible to transmit signal wireless with use of LC-512X wireless sticks.
Always review each component’s installation guide for detailed and up-to-date
wiring instructions. Install in accordance with NEC and local regulations.
Method 1 : H-DMX2108A-5M-3 DMX Decoder Method 2 : H
-DMX2108A-5M-3 DMX Decoder![LED WORLD HUEDA Multi Zone LED Color Controller
- fig 10](https://manuals.plus/wp-content/uploads/2023/05/LED-WORLD-HUEDA-
Multi-Zone-LED-Color-Controller-fig-10.png) Method 1 : LT-840-6A DMX
Decoder Use a compatible Class 2 constant
voltage driver. It is recommended to load the driver no more than 80%.
For additional information and questions please contact our technical support.
Method 2 : LT-840-6A DMX Decoder Use a compatible Class 2 constant voltage driver. It is recommended to load the driver no more than 80%.
For additional information and questions please contact our technical support.
HUEDA™ APP WIFI CONNECTIVITY INSTRUCTIONS
Step 1 :
Turn on the HUEDA™ Master Controller. Blue light on middle of the color circle
indicates that HUEDA™ controller is turned on.
Step 2 :
On your iOS device go to wifi settings. From the available wifi networks look
for Easy lighting or Hueda. Select the Easy lighting or Hueda as the wifi
network. Enter the password 0123456789.
Step 3 :
Open the HUEDA™ App on your iOS device. Use Color Circle on the app to change
the color to make sure that HUEDA™ app is connected to HUEDA™ Master
Controller device wifi. It will not change the color if the HUEDA™ app is not
connected to Mater Controller wifi. Follow above steps to make sure that app
is connected to Mater Controller wifi. Step 4 :
To connect to Home Wifi network while changing color with HUEDA™ app, go to
settings tab on HUEDA™. Select the Master Controller MAC address. It will
bring to you network settings page. From the available settings select the
Connect to Home Network and follow the instructions to connect to Home wifi
network.
ledworldlighting.com
ledworld.ca
1-800-387-4081
LED World Inc.
130 10615 48 ST SE
CALGARY, AB T2C 2B7
CANADA
Version 4.1 12/22/22
Copyright © 2022 LED WORLD INC™.
All Rights Reserved.
We are not responsible for errors or omissions.
Product and specifications subject to change without notice.
Registered trademarks are owned by their respective registers, or licensee(s).
References
- LED World Canada - A Commercial LED lighting supplier
- LED World Lighting - A Commercial LED lighting supplier
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>