Safety Precaution

Warning
Installation and maintenance work shall only be performed by qualified persons, familiar with local code and regulation, and experienced with this type of appliance.
All field wiring must be installed in accordance with the national wiring regulation.
Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.
The appliance must be permanently connected to the electricity supply through a double pole switch having a contact separation of at least 3mm in all poles
The unit must be GROUNDED to prevent possible hazard due to insulation failure.
The earth wire is approximately 60mm longer than safety wire. This is to ensure at the event whereby the suspension system fails, the (L) and (N) wire will break  leaving the fan remain earthed to prevent electrocution.
Tighten the blade firmly using a screw driver.
Blades that are detached from the unit during operation will cause serious injuries and property damages.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge,  unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliances.
Confirm that the power supply has been switched OFF before installing or servicing the unit. Ensure that the blade is fully static before doing any maintenance work.

STOP using the ceiling fan when any abnormality or failure occurs.
If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably qualified persons.

CAUTION
Please take note of the following important points when installing.
The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan.
The mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons.
The fan is to be installed so that the blades are more than 2.5m above the floor.
Safety cord should not be longer than the earthing conductor.
Should failure of the suspension system occur, the supporting of the fan must not rely on the earthing conductor. The earthing terminal in the fan assembly should be  such that should any part of the suspension system fall off, the body of the fan assembly shall effectively earthed.
Ensure that the unit’s panel is closed after service or installation.
Unsecured panels will cause the unit to operate noisily.
Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places.
Before turning off the power supply set the remote controller’s ON/OFF switch to the “OFF” position.
If this is not done, the unit’s fans will start turning automatically when power resumes, posing a hazard to service personnel or the user.
Do not operate any heating apparatus too close to the ceiling fan unit or use in room where mineral oil, oil vapor or oil steam exist, this may cause plastic part to melt  or deform as a result of excessive heat or chemical reaction.
Avoid the ceiling fan unit from exposing to direct sunlight, this may cause degradation of plastic material as a result of excessive heat and UV radiation.
Ensure the color of wires of the outdoor unit and the terminal markings are same to the indoors respectively.
Do not use joined and twisted wires for incoming power supply.
Do not place any object in the path of the blades. Avoid raising objects or your arms near the ceiling fan.
The fan suspension system and blade screw tightening shall be examined yearly.
Replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.
Torque value for screw/bolts for securing primary suspension system for motor is 2Nm.

Parts & Accessories

COSA M1 5B 56 Ceiling Fan - Accessories

Installation Instruction

IMPORTANT : SWITCH OFF THE ELECTRICAL MAINS AT THE CIRCUIT BREAKER FUSE BOX.
Step 1 – Route all the wires from the Motor through the Donwood. Fix the Donwood to the Motor Assembly with Bolt, Washer, Nut and tighten them firmly then insert  the Clevis Pin.
IMPORTANT : Clevis Pin MUST be inserted to prevent Nut from loosening.

Step 2 – Assemble the Canopy and Coupling Cover through the Donwood.

Step 3 – Remove the Bolt, Clevis Pin, Nut, Washer and Rubber Pulley from the Donwood.
Place the Rubber Pulley onto the ceiling hook and fix back the Bolt, Clevis Pin, Nut and Washer.
IMPORTANT : Clevis Pin MUST be inserted to prevent Nut from loosening.

Step 4 – Remove the Safety Wire screw and spring washer from the Downrod.
IMPORTANT : Clevis pin MUST be inserted to prevent Nut from loosening.

Step 5 – Tie the Safety Wire across the hook as shown.COSA M1 5B 56
Ceiling Fan - Safety Wire

Step 6 – Firmly screw the Safety Wire with spring washer onto the Donwood.

Step 7 – Connect the Connectors from Fan and Receiver. Connect the wires from the receiver to House’s Supply Wire. Connect Earth Wire to House Supply Earth Terminal.

COSA M1 5B 56 Ceiling Fan - Supply Wires

Step 8 – Install the Blades on Motor with Blade Screw and Washer.
IMPORTANT : Assemble the Fan Blades only after the ceiling fan is mounted on the hook.COSA M1 5B 56 Ceiling Fan - Supply
Wires1

Below shows a complete installation diagram.

COSA M1 5B 56 Ceiling Fan - Supply Wires2

Transmitter Learning Process

IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO REGULATOR OR DIMMER SWITCH.
The receiver & transmitter is pre-programmed in factory. If you wish to control 2 or more fans using 1 transmitter, the below steps are required.
DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS
Step 1
a) Insert the 2 pcs of batteries (provided) into transmitter.
b) Turn on the power supply (wall switch) to the fan.
c) Within 10 sec, press and hold the “1” and “2” button for 3 sec. Once the receiver has detected the frequency, transmitter will “Beep Beep” twice. Programming  process is completed and fan is ready to use.
If the fan is not responding to the transmitter, repeat Step 1b.

Transmitter Assembly & Operation

IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO REGULATOR OR DIMMER SWITCH.

Function of Transmitter
1 to 6 – Fan speed control
OFF – On/Off the fan
1H – Fan stops after 1hr
3H – Fan stops after 3hr
6H – Fan stops after 6hr

The transmitter & receiver is incorporated with last memory function. This function stores your last setting in memory and the next time you turn on the fan, fan will  operate as the last setting.

Power Supply Connection

COSA M1 5B 56 Ceiling Fan - Power Supply1

IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO REGULATOR OR DIMMER SWITCH.

Circuit Diagram

COSA M1 5B 56 Ceiling Fan - Circuit Diagram

Maintenance

Due to the fan’s natural movement, connections may get loose after period of usage. To ensure a proper and safety usage, it is highly recommended to inspect and  tighten all connections every 6 months.
Cleaning
Cleaning your fan periodically will prolong its new appearance. Basic cleaning procedures are as follows :

  1. Use only water and mild soap. Do not use solvents, corrosive or acidic solution.
  2. Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will scratch the surface.
  3. Do not bent the blades while cleaning. At the event where blades are bent or damage, order new set of blades from service center or dealer shop.
  4. There is no need to oil the fan.

Technical Specifications

Model M1-5B/56 M1-5B/40
No. of Blades 5 5
Fan Width 1420mm (56”) 1015mm (40”)
Motor RPM 85 – 210 102 – 240
Voltage 220-240V~ 50Hz 220-240V~ 50Hz
Motor Wattage 20W – 75W 30W – 75W
Nott Weight 5.8kg 4.8kg
Gross Weight 6.8kg 5.6kg

COSA M1 5B 56 Ceiling Fan - Power Supply2

Customer Service Centre
If you need any technical assistance or faulty report, please contact our customer service center at :

Alpha Home Appliances SD. Bhd. (390258-H)

Head Office : 6, Jalen Sungai Kayo Ara 32/37, Berjaya Park, Section 32, 40460 Shah Allam, Selangor.
COSA logoTel : 03-5740 6666
Fax : 03-5740 8220
Website : www.alphamalaysia.com
Email : info@alphamalaysia.com
Johor Bahru : 71, Jalen Malek 3/10, Taman Malek, 81100 Johor Bahru.
Tel : 07-353 4833 / 4933 Fax : 07-355 4233
Melaka : 19, 19-1 & 19-2, Jalen KSB 11, Taman Kota Syahbandar, 75200 Melaka.
Tel : 06-292 6292 / 6293 Fax : 06-292 6296
Ipoh : 11, Laluan Task Timer 5, Taman Task Indra, 31400 Ipoh, Perak.
Tel : 05-545 2282 / 547 2282  Fax : 05-547 6282
Penang : 28, Jalen Icon City, Icon City, 14000 Bukit Metacam, Penang.
Tel : 04-506 2366 / 2066 / 2566 Fax : 04-506 2966
Pahang : A131, TK1, Jalen Wang Ah Jang, Taman Liza, 25100 Kuantan, Pahang.
Tel : 09-516 5226 Fax : 09-513 9226

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals