Beacon LIGHTING 21300101 Lucci Airfusion Aria Ceiling Fan Instruction Manual

June 4, 2024
Beacon LIGHTING

Beacon LIGHTING 21300101 Lucci Airfusion Aria Ceiling Fan

Beacon-LIGHTING-21300101-Lucci-Airfusion-Aria-Ceiling-Fan-product-
image

THANK YOU FOR PURCHASING

Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and save all instructions before using the product.

SAFETY PRECAUTIONS

  1. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
  2. Children should be supervised to ensure that they do not play with the appliance.
  3. An all-pole disconnection switch must be incorporated into the fixed wiring, in accordance with local wiring rules.
  4. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the ground water and get into the food chain, damaging your health and well-being.
  5.  The structure to which the fan is to be mounted must be capable of supporting a weight of 20kg.
  6. The fan should be mounted so that the blades are at least 2.1 m above the floor.
  7. This fan is suitable for indoor, alfresco and coastal areas where the fan is fully undercover with a minimum of 1 wall. This fan is not waterproof. When installed in an alfresco or coastal area, the ceiling fan must be positioned in a location protected from water, wind and dust. Exposure to these elements will void the warranty. Mounting the fan in a situation where it is subject to water or moisture is dangerous and may increase the risk of damage, injury or electrical shock and will void the warranty.
  8. Must be assembled and installed by a licensed electrician.
  9. WARNING: If unusual wobbling or oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably qualified persons.
  10. The replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.
  11. The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan; that the mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons

BEFORE INSTALLATION

  • Unpack your ceiling fan carefully. Remove all parts and hardware.
  • Lay out all the components on a smooth surface and make sure there are no components missing before assembling. If parts are missing, return the complete product to the place of purchase for inspection or replacement.
  • Check whether the ceiling fan has been damaged during transport. Do not operate/install any product which appears damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement.
  • Examine all parts, you should have the following:
    Beacon-LIGHTING-21300101-Lucci-Airfusion-Aria-Ceiling-
Fan-01
1 Mounting bracket x 1 5 Mounting screws    x 2
2 Fan assembly    x 1 6 Spare Motor screw for blade x 1
3 Blades    x 4 7 Spare Flat washer for blades x 1
4 Bottom cover   x 1 8 Balancing kit    x 1
9 Wall controller    x 1 (included 2 pcs wall switch screws)

INSTALLING THE FAN

TOOLS REQUIRED:

  • Phillips / flat head screwdriver
  • Pair of pliers
  • Adjustable spanner
  • Step ladder
  • Wire cutter
  • Wiring, supply cable as required by local provincial and national wiring codes and regulations

INSTALLING THE MOUNTING BRACKET

  • The ceiling fan must be installed in a location so that the blades are spaced 300mm from the tip of the blade to the nearest objects or walls.
  • Secure the hanging bracket to the ceiling joist or structure that is capable of carrying a load of at least 20kg, with two long screws provided. Ensure at least 30mm of the screw is threaded into the support.

Beacon-LIGHTING-21300101-Lucci-Airfusion-Aria-Ceiling-
Fan-2

NOTE: The bracket screws provided are for use with wooden structures only. For structures other than wood, the appropriate screw type MUST be used. Ensure the screws used are suitable for the mounting surface and the surrounding environment.

ANGLED CEILING INSTALLATION
This fan hanging system supports a maximum 15 degree angled ceiling installation.

INSTALLATION OF BLADE (Fig. 4)

  1. Before Installing the blades, remove the motor blade screws and flat washers from the bottom of the fan motor assembly.

  2. Align the 2 holes on the blade with the 2 holes on the rotating member of the fan motor assembly.

  3. Use the 2 blade screws from step 1, to secure the blade onto the fan motor assembly.
    Ensure all screws are tightened evenly to reduce the chance of warping or unbalancing. Take care not to over tighten the screws, as this can damage the blades.

  4. Repeat the same process for the other blades.

INSTALLATION OF BOTTOM COVER (Fig. 5)

  • Install the bottom cover to the fan assembly then secure it by turning clockwise.
    Beacon-LIGHTING-21300101-Lucci-Airfusion-Aria-Ceiling-
Fan-4
HANGING THE FAN

Lift the fan assembly onto the mounting bracket. Ensure the registration slot (A) of the hanger ball is positioned on the stopper (B) of the mounting bracket (C) to prevent the fan from rotating when in operation. (Fig.6)
Beacon-LIGHTING-21300101-Lucci-Airfusion-Aria-Ceiling-
Fan-12

ELECTRICAL WIRING DIAGRAM
PREPARE AND COMPLETE THE ELECTRICAL WIRING — WIRING DIAGRAM (FIG.7)
WARNING: FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A LICENSED ELECTRICIAN.
NOTE: AN ADDITIONAL ALL POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING.
Ensure the motor earth wire is connected to the single earthing terminal block “1” in the diagram below. (Fig. 7)
NOTE: Wiring diagram includes the light kit wiring. The light wiring diagram and switch is omitted when no light kit is used with the ceiling fan.

USE WITH WALL SWITCH WIRING DIAGRAM:

Beacon-LIGHTING-21300101-Lucci-Airfusion-Aria-Ceiling-
Fan-6

USE WITH REMOTE WIRING DIAGRAM: (REMOTE sold separately)

Beacon-LIGHTING-21300101-Lucci-Airfusion-Aria-Ceiling-
Fan-7 Beacon-
LIGHTING-21300101-Lucci-Airfusion-Aria-Ceiling-Fan-8

FINISHING THE INSTALLATION

  • After completing the electrical connection at the mounting bracket terminal block, connect the ceiling fan wiring via the quick connector plug.
  • Cover the mounting bracket with the canopy. Ensure all electrical wiring is tucked inside the canopy and that the wires are not damaged during this step. Secure the canopy to the hanger bracket using the screws provided.
    Beacon-LIGHTING-21300101-Lucci-Airfusion-Aria-Ceiling-
Fan-9

USING YOUR CEILING FAN

FAN WALL CONTROL
Turn on the power and check the operation of the fan.

  • OFF Position – Fan off
  • 3rd Position – Low fan speed
  • 2nd Position – Medium fan speed
  • 1st Position – High fan speed

Light Control

  • Toggle Switch – On/off (the fan is without light )

REVERSING SWITCH
Your ceiling fan can operate in either summer or winter mode.
SUMMER Mode: The reverse switch shall be in the “down” (SUMMER) position to make the fan rotate in an anticlockwise direction. The airflow will be directed downwards, for cooling in summer.
WINTER Mode: The reverse switch shall be in the “up” (WINTER) position to make the fan rotate in a clockwise direction. The airflow will be directed upwards assisting in the circulation of warm air, for energy conservation in winter.

AFTER INSTALLATION

  • WOBBLE:
    NOTE: ceiling fans tend to move during operation due to the fact that they are mounted on a rubber grommet. If the fan was mounted rigidly to the ceiling it would cause excessive vibration. Movement of a few centimetres is quite acceptable and DOES NOT suggest any problem.
    TO REDUCE THE FAN WOBBLE: Please check that all screws which fix the mounting bracket and down rod are secure. BALANCING KIT: A balancing kit is provided to balance the ceiling fan on initial installation. Please refer to the instruction on how to use the balancing kit. The balancing kit can be used to assist re-balancing should the ceiling fan become un-balanced again. Store your balancing kit away after installation for future use if required.

  • NOISE:
    When it is quiet (especially at night) you may hear occasional small noises. Slight power fluctuations and frequency signals superimposed in the electricity for off-peak hot water control, may cause a change in fan motor noise. This is normal. Please allow a 24-hour “settling-in” period, most noises associated with a new fan disappear during this time. The manufacturer’s warranty covers actual faults that may develop and NOT minor complaints such as hearing the motor run – All electric motors are audible to some extent.

CARE & CLEANING

NOTE: Always turn OFF the power at the mains switch before performing any maintenance or attempting to clean your fan.

  • Every 6 months periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint free cloth to avoid scratching the paint finish. Please turn off electricity power when you do so.
  • Do not soak or immerse your ceiling fan in the water or other liquids. It could damage the motor or the blades and create the possibility of an electrical shock.
  • Ensure that the fan does not come in contact with any organic solvents or cleaners.
  • To clean the fan blade, wipe with only a damp clean cloth with NO organic solvents or cleaners.
  • The motor has a permanently lubricated ball bearing so there is no need to oil.

TECHNICAL INFORMATION

Fan| 36’’ ARIA fan only
Fan Models| ARIA 36”-WS-WH; ARIA 36”-WS-BK / SKU# 213003; 213004
Rated Voltage| 220-240V~ 50Hz
Rated Wattage (Motor)| 45W
Rated wattage (Lamp)| N/A
Battery for remote| N/A
Weight| 4.6kg
Canopy Dimensions| H:50mm     Dia:136mm

LUCCI CEILING FAN WARRANTY DETAIL

Online Warranty Form: https://www.beaconlighting.com.au/warranty-claims
Email: [email protected]
Lucci Fan Warranty Hotline: (Free Call) 1800 602 243

THIS WARRANTY IS VALID IN AUSTRALIA ONLY
In the event of service being required, please call the Lucci Fan Warranty Hotline on 1800 602 243 between 9am & 5pm (EST) Monday to Friday. Please make sure you have all the ceiling fan details filled out at the end of the manual before making the call.
Every Lucci ceiling fan is thoroughly inspected and tested before being released for sale. In addition to any warranty rights or conditions under statutory regulations, Lucci warrants all of its ceiling fans against defective workmanship and faulty materials for twenty four (24) months from the date of purchase. Lucci undertakes, at its option, to repair or replace, free of charge, each product or part thereof on condition that;

  1. The fan or relevant part has not been subjected to misuse, neglect, or been involved in an accident.
  2. The repairs are not required as a result of normal wear and tear.
  3. The product was installed by a licensed electrical contractor.
  4. A copy of the original receipt of purchase is presented.
  5. 12 month warranty applies when used in any non-domestic applications.
  6. This warranty does not cover stains, scratch and scuff marks, or dents if the product is purchased through a factory outlet or to refurbished items.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Lucci Design cannot be held responsible for any repair other than those carried out by it or one of its Authorized Service Agents. Please keep this warranty information in a safe place. This information must be produced in the event of service being required.
Distributed by:
Beacon Lighting
140 Fulton Drive
Derrimut, Victoria, 3026
Australia
Ph +613 9368 1000
Email: [email protected]
THIS COMPLETED DETAIL PAGE SHOULD BE PRODUCED AND SENT TO THE WHOLESALER OR THEIR AUTHORISED AGENTS BEFORE OBTAINING WARRANTY SERVICE

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Beacon LIGHTING User Manuals

Related Manuals