CAUTION
READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION.

Fanaway Orbit Installation Instructions

THANK YOU FOR PURCHASING

Thank you for purchasing this quality Fanaway product. To ensure correct function and safety, please read and follow all instructions carefully before assembly, installation, and use of this ceiling fan. Please keep instructions for future reference.

SAFETY PRECAUTIONS

  1. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

  2. Children should be supervised to ensure that they do not play with the appliance.

  3. An all-pole disconnection switch must be incorporated into the fixed wiring, in accordance with local wiring rules.
    IN AUSTRALIA
    WARNING:
    FOR SAFE USE OF THIS FAN AN ALL-POLE DISCONNECTION MUST BE INCORPORATED INTO THE FIXED WIRING IN ACCORDANCE WITH THE WIRING RULES.
    As outlined in clause 7.12.2 of AS/NZS 60335-1 for meeting the minimum electrical safety of this standard.
    Please note warranty will be void if installation is without a means for an all-pole disconnection incorporated in the fixed wiring in accordance with the wiring rules.
    Example: If a fan is connected to a circuit that can be isolated via an all- pole safety switch at the switchboard, then this is considered to be an all- pole disconnection to the ceiling fan electrical circuit, meeting the requirements of clause 7.12.2 of AS/NZS 60335.1.
    A single-pole switch on the activities of receiver input of the remote control must also be included in the wiring and located in the same room as the ceiling fan.

  4. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being.

  5. The structure to which the fan is to be mounted must be capable of supporting a weight of 32 kg.

  6. The fan should be mounted so that the blades are at least 2.1 m above the floor in Australia.

  7. This fan is suitable for indoor use only. Mounting the fan in a location where it is subject to water or moisture is dangerous and may increase the risk of damage, injury or electrical shock and will void the warranty.

  8. Must be assembled and installed by a licensed electrician.

  9. WARNING: If unusual wobbling or oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent, or suitably qualified persons.

  10. The replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent, or suitably qualified persons.

  11. The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with sufficient strength to withstand 4 times the weight of the ceiling fan; the mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons.

  12. The light source contained in the luminaire is non-user replaceable. It shall only be replaced by the manufacturer or his service agent or a similarly qualified person. The shade of the Light kit assembly MUST
    NOT be removed during cleaning, maintenance, or any other circumstances.

PARTS LIST

  • Unpack your ceiling fan carefully. Remove all parts and hardware.
  • Lay out all the components on a smooth surface and make sure there are no components missing before assembling. If parts are missing, return the complete product to the place of purchase for inspection or replacement.
  • Check whether the ceiling fan has been damaged during transport. Do not operate/install any product which appears damaged in any way. Return the complete product to the place of purchase for inspection, repair, or replacement.
  • Examine all parts, you should have the following:
    Mounting bracket x 1| 5| Mounting screws 4 pcs
    ---|---|---
    Fan assembly x 1| 6| Wall switch x 1 set
    Light kit plate x 1| 7| Wall switch screws x 2 pcs
    Light kit assembly with LED and shade x 1| |

INSTALLING THE FAN

TOOLS REQUIRED:

  • Phillips / flathead screwdriver
  • Pair of pliers
  • Adjustable spanner
  • Step ladder
  • Wire cutter
  • Wiring, and supplying cable as required by local provincial and national wiring codes and regulations

INSTALLING THE MOUNTING BRACKET

  • The ceiling fan must be installed in a location so that the blades are spaced 300mm from the tip of the blade to the nearest objects or walls.

  • Install the hanging bracket to the ceiling joist or structure that is capable of carrying a load of at least 32kg, with the 4 long screws provided. Ensure at least 30mm of the screw is threaded into the support. (Fig. 2)

  • NOTE: The bracket screws provided are for use with wooden structures only. For structures other than wood, the appropriate screw type MUST be used. Ensure the screws used are suitable for the mounting surface and the surrounding environment.
    ANGLED CEILING INSTALLATION
    The hanging system of this fan is ONLY suitable for flat ceiling installation.
    DO NOT install the fan on an angled ceiling.

HANGING THE FAN ASSEMBLY

  • Lift the fan assembly(1)up to the mounting bracket. Hang the fan assembly onto the J-hook (2) of the mounting bracket. (Fig.3)

  • Complete the electrical wiring according to the ‘ELECTRICAL WIRING DIAGRAM’ section below.
    PREPARE AND COMPLETE THE ELECTRICAL WIRING — WIRING DIAGRAM (FIG. 4)

  • WARNING: FOR YOUR SAFETY ALL ELECTRICAL CONNECTIONS MUST BE UNDERTAKEN BY A LICENSED ELECTRICIAN.

  • NOTE: AN ADDITIONAL ALL-POLE DISCONNECTION SWITCH MUST BE INCLUDED IN THE FIXED WIRING.

  • Ensure the motor earth wire is connected to the single earthing terminal block “1” in the diagram below.

  • USE WITH WALL SWITCH WIRING DIAGRAM: (Fig.4)

USE WITH REMOTE WIRING DIAGRAM: (REMOTE sold separately)
Ensure the motor earth wire is connected to the single earthing terminal block “1” in the diagram (Fig.5 and Fig.6)

  1. Remote without plugs (manual wiring) Fig. 5

  2. Remote with plugs (using quick connectors)

INSTALL THE FAN ASSEMBLY TO THE MOUNTING BRACKET

  • After completing the electrical connection at the mounting bracket terminal block, connect the ceiling fan wiring via the quick connector plug.

  • NOTE: Ensure the earth wiring is secure and correct, by performing an earthing continuity test from the fan’s accessible metal body back to the earth terminal at the terminal block on the mounting bracket.
    Install the fan assembly to the mounting bracket (Fig.7a):

  • Loosen two canopy screws (1) and remove them from the mounting bracket.

  • Loosen two canopy screws with star washer (2) by half thread from the mounting bracket. (For L-shape slot on canopy to be mounted).

  • Lift the hanging canopy (3) of the fan assembly up to the mounting bracket and let the L-shape slot on the hanging canopy (3) go through the two canopy screws with the star washer (2).

  • Turn the hanging canopy (3) until it locks in place at the end section of the L-shape slot, and ensure the star washer is between the hanging canopy (3) and the screw head. Secure it by tightening the two canopy screws with a star washer (2).

  • Secure and tighten the canopy screws (1) to the mounting bracket. The hanging canopy (3) shall have 4 screws (1) & (2) in total. Avoid damaging the electrical wiring prepared previously when hanging the canopy.

LIGHT KIT INSTALLATION

LIGHT KIT INSTALLATION (Fig. 6 & 7)

  1. Loosen the screw (2) from the fan bracket. Align the two slot screws (1 and 3) with the keyhole slots (1 and 3) of the light kit plate. (Fig. 6)

  2. Turn the light kit plate counterclockwise until the slot screws(1 and 3) are firmly at the end of the slots (1 and 3).

  3. Secure screw (2) to the light kit plate. Tighten all three screws. Do not over-tighten.

  4. Connect the quick connector to the light kit assembly with LED and shade. (Fig. 7)

Finally, install the light kit assembly with LED and Shade to the light

kit plate by turning it clockwise (Fig. 7)
USING YOUR CEILING FAN

FAN WALL CONTROL (Fig. 8)

Turn on the power and check the operation of the fan.

  • OFF Position – Fan Off
  • 3rd Position – Low fan speed
  • 2nd Position – Medium fan speed
  • 1st Position – High fan speed

LIGHT CONTROL (Fig .8)

  • Toggle Switch – ON / OFF
    Fig. 8
    The LED Light Kit has a 3-step dimmable function which is controlled by an ON/OFF switch. Toggle the switch ON/OFF to the luminaire 4 times within 5 seconds, the globe will light up in the following order:
    100% brightness → 60% brightness → 10% brightness → 100% brightness
    To switch back to 100% brightness at any stage, turn OFF the luminaire, and then after 5 seconds turn the luminaire, it will reset to 100% brightness.

REVERSING FUNCTION (Fig. 9)

Your ceiling fan can operate in either summer or winter mode.

SUMMER Mode: The reverse switch should be in the SUMMER position to rotate the fan in an anticlockwise direction. The airflow will be directed downwards, for cooling in summer.

WINTER Mode: The reverse switch should be in the WINTER position to rotate the fan in a clockwise direction. The airflow will be directed upwards assisting in the circulation of warm air, for energy conservation in winter.


AFTER INSTALLATION

WOBBLE:
NOTE: ceiling fans tend to move during operation due to the fact that they are mounted on a rubber grommet.
If the fan was mounted rigidly to the ceiling it would cause excessive vibration. Movement of a few centimeters is quite acceptable and DOES NOT suggest any problem.
TO REDUCE THE FAN WOBBLE:
Please check that all screws fix the mounting bracket.
NOTE: This fan has been precision balanced at the factory and will not need to be balanced again.
NOISE:
When it is quiet (especially at night) you may hear occasional small noises. Slight power fluctuations and frequency signals superimposed in the electricity for off-peak hot water control may cause a change in fan motor noise. This is normal. Please allow a 24-hour “settling-in” period, most noises associated with a new fan disappear during this time.
Please note that this is not a product fault and as such is not covered under warranty – All electric motors are audible to some extent.

CARE & CLEANING

NOTE: Always turn OFF the power at the mains switch before performing any maintenance or attempting to clean your fan.

  • Every 6 months periodic cleaning of your ceiling fan is the only maintenance required. Use a soft brush or lint-free cloth to avoid scratching the paint finish. Please turn off the electrical power when you do so.
  • Do not soak or immerse your ceiling fan in water or other liquids. It could damage the motor or the blades and create the possibility of an electrical shock.
  • Ensure that the fan does not come in contact with any organic solvents or cleaners.
  • To clean the fan blade, wipe with only a damp clean cloth with NO organic solvents or cleaners.
  • The motor has a permanently lubricated ball bearing so there is no need to oil.

TECHNICAL INFORMATION

Fan| 36″ fan – Fanaway Orbit
Fan Models| LD-36 CTC FAN (SKU# 210664 / 210665 / 210666
Rated Voltage| 220-240V- 50Hz
Rated Wattage (Motor)| 55W
Rated wattage (Lamp)| 25W, 2000 LM, 3000K, Dimmable(3-step dimming)
Weight| 7.9kg
Canopy Dimensions| H:60mm Dia:150mm

Warranty

THIS WARRANTY IS VALID IN AUSTRALIA ONLY
Note:

Please complete the following details when you have unpacked the product and retain this card with the purchase invoice or sales docket.
Warranty
These products are covered by a Warranty in addition to all rights available to you by statute. The Warranty is for a
period of twenty-four (24) months from the date of purchase, subject to the following conditions. Fanaway undertakes, at
its option, to repair or replace, free of charge, each product or part thereof subject to the following conditions. The
conditions abovementioned are:

  1. That the purchaser carefully follows all instructions provided and complies with electrical wiring regulations;

  2. That the purchaser carefully follows the installation instructions provided in the owner’s handbook relating to the proper use and care of the product and does not use the product for any purpose other than the domestic use for which it has been designed;

  3. That the product was purchased and is installed in Australia;

  4. That this Warranty does not extend to:
    A. Optional light diffusers
    B. Light globes
    C. Damage to plastic light dome caused by inappropriate cleaning
    D. Damage to surface coatings caused by cleaning or maintenance using inappropriate cleaning products
    E. Defects caused by normal wear and tear, accident, negligence, alteration, or misuse;
    F. A product dismantled, repaired, or serviced by any serviceman other than an authorized employee or agent of Fanaway
    G. Product installed by an unqualified person. Must be a qualified electrician in Australia
    H. Damage or defects caused by fans being installed externally.
    (FANS ARE DESIGNED FOR INDOOR USE ONLY).

  5. The provisions of this warranty do NOT apply to other Ceiling Fans.

  6. The provision of service under this Warranty is limited by the boundary of the nearest service agent’s area.
    Traveling cost incurred for the service outside this area is not covered by this warranty and will incur commercial costs to be paid by the customer regulated by the number of kilometers traveled beyond the service area.

  7. The cost associated with the hire of extension ladders and scaffolding to service fans installed on ceilings greater than 3 meters will not be covered by this warranty. Such costs will be borne by the customer.

In the event of a service being required, please call the Lucci Warranty Service Hotline acting as the service agent for Fanaway on 1800 602 243 between 9 AM and 5 PM (E.S.T) Monday to Friday. Ensure you have the following details on hand. If you are unable to establish the date of purchase, or the fault is not covered by this Warranty, or if the product is found to be in working order, you will be required to bear all service call charges.
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

CONTACTS:
Contact Lucci Warranty Service Hotline acting as the service agent for Fanaway on 1800 602 243 between 9 AM and 5 PM (E.S.T) Monday to Friday, or go to Website: for more information.

Distributed by:
Beacon Lighting
140 Fulton Drive
Derrimut, Victoria, 3026
Australia
Ph +613 9368 1000
Fax +613 9360 9332
Email:warranty@beaconlighting.com.au
This fan is suitable for indoor use only.

Documents / Resources

| Beacon LIGHTING 21066601 Fanaway Orbit Ceiling Fan [pdf] User Manual
21066601, Fanaway Orbit Ceiling Fan, 21066601 Fanaway Orbit Ceiling Fan, Orbit Ceiling Fan, Ceiling Fan, Fan
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Beacon LIGHTING User Manuals

Related Manuals