beckett CB501ULHTSP Condensate Removal Pump Instruction Manual

June 10, 2024
beckett

beckett CB501ULHTSP Condensate Removal Pump

beckett-CB501ULHTSP-Condensate-Removal-Pump-product

Product Information

Condensate Removal Pump

The Condensate Removal Pump is available in multiple models, including CB501ULHTSP, CB502ULHTSP, CB504ULHTSP, CP651ULHTSP, and CP654ULHTSP. The pump is designed to remove condensate from air conditioning coils and is equipped with safety features to prevent electrical shocks. The pump features a tank, inlet, outlet, piping, stand, copper tube, nut inner ring, check valve, ball- cage snap ring ball adapter, and designated pump lift.

Product Usage Instructions

Condensate Removal Pump

  1. For plenum installations, only use metallic tubing for the intake and discharge, and metal conduit for wiring.
  2. Carefully read the Owner’s Manual and rules for safe operation before using the pump.
  3. Ensure that all wiring conforms to local codes and use the National Electric Code if local code is nonexistent.
  4. Before servicing the pump, disconnect it from the power supply and pull the plug on models that have plug-in connections.
  5. Do not handle the pump with wet hands or when standing in water as fatal shock could occur. Disconnect main power before handling unit for ANY REASON!
  6. Protect the power cable from coming in contact with sharp objects.
  7. Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces or chemicals.
  8. Ensure that line voltage conforms to the voltage specified on motor and nameplate.
  9. To reduce risk of electrical shock, connect only to a properly grounded grounding type receptacle.
  10. Select a location for the pump that is as near as possible to the air conditioning coil but avoid any water spray or drops on or near the motor and switch cover. The pump must be level, and the inlet hole must be below the coil drain.
  11. Unpack the pump carefully and remove the switch cover. Check each float rod for free action.
  12. Comply with local codes when wiring the pump. Turn off the electric power at the fuse box before making any line voltage connections.
  13. To test the safety float switch, temporarily stop flow of discharge line by sharply bending vinyl tubing. Pour more water into pump inlet. Water level will rise beyond high level of control float until safety float switch breaks the Y thermostat circuit shutting down air conditioner condensing unit. Unbend the tube, and the pump will empty the entire sump. Replace inlet line into pump inlet.
  14. Maintain the pump by removing dirt that may collect in bottom sump and ensuring that vinyl DISCHARGE LINE is open and water can pass through freely. Always replace cover to keep electrical parts clear of dust and grime.

MODEL: CB501ULHTSP, CB502ULHTSP, CB504ULHTSP, CP651ULHTSP, CP654ULHTSP

RULES FOR SAFE OPERATION

  1. For plenum installations use only metallic tubing for the intake and discharge, and metal conduit for wiring.
  2. Carefully read the Owners Manual and rules for safe operation.
  3. All wiring must conform to local codes. Use the National Electric Code if local code is nonexistent.
  4. CAUTION! To reduce risk of electric shock disconnect from power supply before servicing, pull the plug on models which have plug-in connections.
  5. Do not handle the pump with wet hands or when standing in water as fatal shock could occur. Disconnect main power before handling unit for ANY REASON!
  6. Protect the power cable from coming in contact with sharp objects.
  7. Do not kink power cable and never allow the cable to come in contact with oil, grease, hot surfaces or chemicals.
  8. Make certain that line voltage conforms to the voltage specified on motor and nameplate.
  9. WARNING! To reduce risk of electrical shock, connect only to a properly grounded grounding type receptacle.

INSTALLATION

Select a location for the pump. It should be as near as possible to the air conditioning coil but avoid any water spray or drops on or near the motor and switch cover. The pump must be level. The inlet hole must be below the coil drain.
Carefully unpack the pump. Remove the switch cover. Check each float rod for “free” action.

beckett-CB501ULHTSP-Condensate-Removal-Pump-fig 2

PIPING

beckett-CB501ULHTSP-Condensate-Removal-Pump-fig
3

Run a drain line from the evaporator coil drain to the pump. Use the flexible plastic pipe where the code permits. Insert the pipe 1” below the pump cover. Do not install inlet drain line that would interfere with operation of floats.
Connect outlet tubing (copper or vinyl) to discharge on pump. Do not run tubing vertical more than is recommended by the lift on each unit.
For good flow, slant the horizontal run downward toward the drain. Each unit comes standard with a check valve for connecting to ½” O.D. copper tubing. A copper tube adapter is included for vinyl hose hook-up.beckett-CB501ULHTSP-
Condensate-Removal-Pump-fig 3

Read and Follow all Safety Instructions.
Save This Manual for Future Reference.

WIRING

The wiring must comply with local codes.

WARNING
Turn the electric power off at the fuse box before making any line voltage connections.beckett-CB501ULHTSP-Condensate-Removal-Pump-fig
4

To test safety float switch, temporarily stop flow of discharge line by sharply bending vinyl tubing. Pour more water into pump inlet. Water level will rise beyond high level of control float until safety float switch breaks the “Y” thermostat circuit shutting down air conditioner condensing unit. Unbend the tube and the pump will empty the entire sump. Replace inlet line into pump inlet.

MAINTENANCE AND TROUBLESHOOTING

  1. Remove dirt that may collect in bottom sump.
  2. Look at vinyl DISCHARGE LINE to see that it is open and water can pass through freely.
  3. Always replace cover to keep electrical parts clear of dust and grime.
  4. See item 7 of Introduction.

LIMITED WARRANTY

Each Beckett Corporation (“Beckett”) product is warranted to be free from defects in material and workmanship for the applicable Warranty Period (herein so called) set forth below. The Warranty Period for each product commences on the date of purchase by the original purchaser. The Warranty Periods are as follows:

Product Type or Name/Warranty Period

  • Pump Models:
    • FR Series, DP800-1800, G Series, W Series …………2 Years
    • UL6500A; XL-6500A ………………………. 2 Years
    • Other Pump Models ……………………….. 1 Year
  • Pre-Formed Poly Ponds ………………………..………. 15 Years
  • Waterfall Weir & Skimmer………………………..……… 5 Years

Product Type or Name/Warranty Period

  • Liner Material:
    • 35 mil PVC …………………………………..20 Years
    • 40 mil EPDM …………………………………20 Years
    • 20 mil PVC …………………………………..15 Years
    • UV9/UV13 Filter ……………………………. 1 Year
  • All Other Beckett Products.……………………………90 Days

A PPLICATION: The warranty covers only properly installed and maintained Beckett products and is limited to application at normal temperature 32º F to 212º F, (0º C to 100º C) p umping fluids with a specific gravity up to 1.1 and with a pH range of 5 to 9 (fresh water). Other liquid applications and extreme temperature uses must be approved in advance by B eckett. The warranty does not apply to or cover damages or defects caused by external causes, including, but not limited to, improper or faulty installation or unauthorized modification, lightning, electrical surges, abuse, misuse or abnormal use or misapplication, including use in a manner inconsistent with the product’s intended function. The purchaser is responsible for determining the suitability of the product for its intended use. If products are damaged in transit, a claim should be filed with the carrier.
REMEDY: If there has been a failure to conform to the warranty, Beckett will, at Beckett’s option, repair, replace or issue a credit or refund for the particular nonconforming product or part. Repair, replacement, credit or refund, at Beckett’s option, is the exclusive remedy in the event of a failure to conform to the warranty. Warranty claims must be made within 3 months after expiration of the applicable Warranty Period.
ADMINISTRATION: Warranty claims must be made by returning the nonconforming Beckett product, freight prepaid, along with proof of purchase, to: Beckett Corporation, Customer Service Dept., Irving, Texas, telephone 888-232-5388. Telephone authorization from Beckett is required prior to returning nonconforming products or parts. All products or parts returned will be inspected to determine cause of failure before warranty is approved.
INSTALLATION, REMOVAL AND/OR SHIPPING CHARGES: The warranty does not cover any costs associated with the installation, removal or shipping of products subject to w arranty claims.
DISCLAIMER AND LIMITATION: THE EXPRESS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. TO THE FULL EXTENT PERMITTED BY LAW, BECKETT EXPRESSLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF IMPLIED WARRANTIES CANNOT BE DISCLAIMED, ALL SUCH IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY.
BECKETT DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES EXPRESSLY SET FORTH IN THIS WARRANTY. IN NO EVENT SHALL BECKETT BE LIABLE OR RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. BECKETT’S AGGREGATE LIABILITY UNDER THIS WARRANTY OR WITH RESPECT TO ANY PRODUCT C OVERED HEREBY, UNDER ANY LEGAL THEORY, SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE NONCONFORMING PRODUCT. THE LIMITATIONS CONTAINED IN THIS PARAGRAPH SHALL NOT APPLY TO INJURY TO THE PERSON.
Some States do not allow the exclusion or limitation of incidental or consequential damages or exclusions or limitations on the duration of an implied warranty, so the above limitations or e xclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights that vary from State to State.

FOR YOUR RECORDS:

  • Date of Purchase __
  • Model Number __
  • Name of Dealer __

PLEASE KEEP RECEIPT IN CASE OF WARRANTY SERVICE.

Irving, Texas
www.beckettpumps.com
Toll Free: 1-888-232 -5388
© 2020 BECKETT CORPORATION All Rights Reserved