IPC13A Beckett Submersible Utility Pumps Owner’s Manual

June 11, 2024
beckett


BECKETT SUBMERSIBLE UTILITY PUMPS
OWNER’S MANUAL
Models: IPC13A & IPC13AT

BE SURE TO READ AND SAVE THIS MANUAL FOR FUTURE REFERENCE.
Beckett Pumps are carefully inspected and tested to ensure both safety and operating performance. However, failure to follow the instructions in this manual may result in pump damage and/or  serious injury.
CAUTION: Read all instructions carefully before starting the installation. IPC13A Beckett Submersible Utility Pumps

WARNING

  • This pump is supplied with a 3-prong type attachment plug.
  • To reduce the risk of electric shock, install only on a circuit protected by a ground-fault circuit-interrupter (GFCI).
  • The pump is to be installed in accordance with state and local codes and that installation and servicing shall be conducted by a qualified person.
  • Do not remove the grounding conductor.
  • Do not connect to any voltage other than that shown on the pump.
  • Do not pump any flammable liquids.
  • This pump has not been tested nor approved for use in air conditioning plenums or other air handling compartments.

INTRODUCTION

The Beckett IPC13A has been designed for a variety of applications where reliable, automatic pump operation is required.
Because the motor and all electrical components are completely encapsulated in epoxy, the unit can be totally submerged and can be operated in any position, provided the Diaphragm Cover is  submerged.
A built-in pressure sensitive switch controls the IPC13A by turning the unit on when the water level reaches a maximum of 1.7” and turning it off when the level falls to a minimum of .7”.  These measurements will be different if the pump is operated in any position other than upright with the filter screen facing down.
The model IPC13AT is identical to the IPC13A, except that is supplied with 20 feet of 3/8” vinyl tubing, a remote Safety Float Switch, and a molded plastic sump tank. Both pump models  include a ¼” N.P.T. female elbow and a plastic check valve to prevent water from draining back into the pump after it has turned off.
CAUTION: This pump has been evaluated for use with water only.

OPERATION

CONDENSATION REMOVAL
Attach the 3/8” barbed check valve to the ¼” N.P.T. elbow, and attach this assembly to the pump’s discharge.

IPC13A Beckett Submersible Utility Pumps - REMOVAL
BE CAREFUL NOT TO OVER-TIGHTEN.
Place the pump in the sump tank or other suitable container as close as possible to the air conditioning drip pan. Be sure the top of the drip pan is at least 2” above the bottom of the pump.
Using 3/8” vinyl tubing, run the discharge up to the minimum distance required, being sure not to exceed 90% of the “SHUT-OFF” height shown in the performance chart.
If possible, slant the horizontal run down slightly to gain the benefit of gravity.
If this pump is installed directly in the air conditioning drip pan, be sure the pan is at least 2” deep and the pump is in the lowest part of the pan.

DE-WATERING
When the IPC13A is used for general pumping jobs such as draining flooded areas, or whenever maximum flow is desired, do not use the check valve. Instead attach ½” vinyl tubing directly to the discharge of the pump and secure the connection with a hose clamp.
If the pump is to be used on a dirty or sandy surface, raise it slightly to prevent dirt or debris from contacting the intake area. Using the pump outdoors may require more frequent cleaning of  the filter screen and impeller area. See instructions for cleaning in MAINTENANCE. TYPICAL PERFORMANCE ±10%

PERFORMANCE

The performance of a pump is measured by its FLOW and its LIFT. In the following chart, the FLOW is expressed in Gallons Per Hour (GPH) and LIFT is expressed in Feet above the surface  of the water. Measurements were taken at 115 volts using 3/8” vinyl tubing.

| TYPICAL PERFORMANCE ±10%
---|---
| GALLONS PER HOUR AT:
| 1′| 2′| 4′| 6′| 8′| 10′| SHUT OFF FEET
WITH CHECK VALVE| 77| 74| 65| 57| 45| 33| 12′
NO CHECK VALVE| 260| 252| 221| 198| 174| 111| 12′

“Shut-Off” is the maximum height the pump will lift water. At the “Shut-Off” point there will be no water flow.
If less flow is desired, restrict the discharge of the pump. DO NOT restrict the intake of the pump as damage to the motor and seal may occur.

FLOAT SWITCH INSTALLATION

The Safety Float Switch may be used to provide additional protection against flooded drip pans by shutting-off the system that is producing the water or condensation in the event the pan  floods, the pump’s discharge becomes clogged, or other malfunction occurs. The switch may be wired to the thermostat circuit or it may be wired to any auxiliary alarm or other warning device.

IPC13A Beckett Submersible Utility Pumps - INSTALLATION
2IPC13A Beckett Submersible Utility Pumps -
INSTALLATION 3

The Safety Float Switch may be installed in the drip pan or it may be mounted to the side of the molded plastic sump tank, as shown.
WARNING: Risk of electric shock, the remote Safety Float Switch is not submersible and should be connected only to an N.E.C. Class II circuit of not more than 30 volts.

MAINTENANCE

WARNING: Always disconnect from electrical outlet before servicing this pump.
Beckett pumps have been designed to provide long, trouble-free service in normal operating conditions. However, if the pump fails to operate, please check the following:

  • Is the pump getting electrical power? Check the circuit breaker and try another outlet to be sure.
  • Has the intake screen become clogged?
  • Are there any kinks or blockages in the discharge tubing?
  • Is the impeller broken or jammed with debris?
  • If the area around the impeller has become encrusted with minerals, it may be necessary to pry-off the impeller and gently scrape the area clean. After cleaning, apply a few crops of light  oil where the impeller shaft enters the motor. Then, press the impeller back on using a penny to gage the spacing between the impeller and impeller back plate.

CAUTION: The cord of this pump contains a small “Breather Tube”.
This tube is necessary for the proper operation of the pressure switch.
Do not allow this tube to become blocked.
Before installing the pump, make sure to remove the breather tube cap.

IPC13A Beckett Submersible Utility Pumps - switch

WARNING: Do not remove the 4 screws that is holding the diaphragm cover in place. There are no serviceable parts in the switch mechanism, removing or loosening these screws may cause  an electrical shock hazard.

LIMITED WARRANTY

Each Beckett Corporation (“Beckett”) product is warranted to be free from defects in material and workmanship for the applicable Warranty Period (herein so called) set forth below. The  Warranty Period for each product commences on the date of purchase by the original purchaser. The Warranty Periods are as follows:

Product Type or Name
Warranty Period

Pump Models:
FR Series, DP800-1800, G Series, W Series …………2 Years
UL6500A; XL-6500A………………………. 2 Years
Other Pump Models……………………….. 1 Year
Pre-Formed Poly Ponds………………………. 15 Years
Waterfall Weir & Skimmer………………………… 5 Years
Liner Material:
35 mil PVC…………………………………..20 Years
40 mil EPDM…………………………………20 Years
20 mil PVC…………………………………..15 Years
UV9/UV13 Filter……………………………. 1 Year
All Other Beckett Products…………………90 Days

APPLICATION: The warranty covers only properly installed and maintained Beckett products and is limited to application at normal temperature 32º F to 86º F, (0º C to 30º C) pumping  fluids with a specific gravity up to 1.1 and with a pH range of 5 to 9 (fresh water).
Other liquid applications and extreme temperature uses must be approved in advance by Beckett. The warranty does not apply to or cover damages or defects caused by external causes,  including, but not limited to, improper or faulty installation or unauthorized modification, lightning, electrical surges, abuse, misuse or abnormal use or misapplication, including use in a  manner inconsistent with the product’s intended function. The purchaser is responsible for determining the suitability of the product for its intended use. If products are damaged in transit, a  claim should be filed with the carrier.
REMEDY: If there has been a failure to conform to the warranty, Beckett will, at Beckett’s option, repair, replace or issue a credit or refund for the particular nonconforming product or part.  Repair, replacement, credit or refund, at Beckett’s option, is the exclusive remedy in the event of a failure to conform to the warranty. Warranty claims must be made within 3 months after expiration of the applicable Warranty Period.
ADMINISTRATION: Warranty claims must be made by returning the nonconforming Beckett product, freight prepaid, along with proof of purchase, to: Beckett Corporation, Customer  Service Dept., Irving, Texas, telephone 888-232-5388. Telephone authorization from Beckett is required prior to returning nonconforming products or parts. All products or parts returned will be inspected to determine cause of failure before warranty is approved.
INSTALLATION, REMOVAL AND/OR SHIPPING CHARGES: The warranty does not cover any costs associated with the installation, removal or shipping of products subject to warranty claims.
DISCLAIMER AND LIMITATION: THE EXPRESS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND  REMEDIES, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. TO THE FULL EXTENT PERMITTED BY LAW, BECKETT EXPRESSLY DISCLAIMS ANY AND ALL  IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF  IMPLIED WARRANTIES CANNOT BE DISCLAIMED, ALL SUCH IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY.
BECKETT DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES EXPRESSLY SET FORTH IN THIS WARRANTY. IN NO EVENT SHALL BECKETT BE LIABLE OR  RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. BECKETT’S AGGREGATE LIABILITY UNDER THIS WARRANTY OR WITH RESPECT TO ANY  PRODUCT COVERED HEREBY, UNDER ANY LEGAL THEORY, SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE NONCONFORMING PRODUCT. THE  LIMITATIONS CONTAINED IN THIS PARAGRAPH SHALL NOT APPLY TO INJURY TO THE PERSON.
Some States do not allow the exclusion or limitation of incidental or consequential damages or exclusions or limitations on the duration of an implied warranty, so the above limitations or  exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights that vary from State to State.

FOR YOUR RECORDS:
Date of Purchase __
Model Number
Name of Dealer

PLEASE KEEP RECEIPT IN CASE OF WARRANTY SERVICE.

BECKETT CORPORATION
Irving, Texas
www.beckettus.com
Toll Free: 1-888-232-5388
© 2019 BECKETT CORPORATION All Rights Reserved

SHOULD YOU ENCOUNTER ANY PROBLEMS WITH THIS PRODUCT,
CONTACT CUSTOMER CARE AT:
1-888-BECKETT
MONDAY THRU FRIDAY, BETWEEN THE HOURS OF 8:00 AM AND 5:00 PM CENTRAL STANDARD TIME. WE ASK THAT YOU DO NOT RETURN THIS PRODUCT TO THE  STORE BEFORE CONTACTING US. YOU CAN ALSO CONTACT US AT OUR WEB SITE: www.beckettus.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals