IPC13A Beckett Submersible Utility Pumps Owner’s Manual
- June 11, 2024
- beckett
Table of Contents
BECKETT SUBMERSIBLE UTILITY PUMPS
OWNER’S MANUAL
Models: IPC13A & IPC13AT
BE SURE TO READ AND SAVE THIS MANUAL FOR FUTURE REFERENCE.
Beckett Pumps are carefully inspected and tested to ensure both safety and
operating performance. However, failure to follow the instructions in this
manual may result in pump damage and/or serious injury.
CAUTION: Read all instructions carefully before starting the
installation.
WARNING
- This pump is supplied with a 3-prong type attachment plug.
- To reduce the risk of electric shock, install only on a circuit protected by a ground-fault circuit-interrupter (GFCI).
- The pump is to be installed in accordance with state and local codes and that installation and servicing shall be conducted by a qualified person.
- Do not remove the grounding conductor.
- Do not connect to any voltage other than that shown on the pump.
- Do not pump any flammable liquids.
- This pump has not been tested nor approved for use in air conditioning plenums or other air handling compartments.
INTRODUCTION
The Beckett IPC13A has been designed for a variety of applications where
reliable, automatic pump operation is required.
Because the motor and all electrical components are completely encapsulated in
epoxy, the unit can be totally submerged and can be operated in any position,
provided the Diaphragm Cover is submerged.
A built-in pressure sensitive switch controls the IPC13A by turning the unit
on when the water level reaches a maximum of 1.7” and turning it off when the
level falls to a minimum of .7”. These measurements will be different if the
pump is operated in any position other than upright with the filter screen
facing down.
The model IPC13AT is identical to the IPC13A, except that is supplied with 20
feet of 3/8” vinyl tubing, a remote Safety Float Switch, and a molded plastic
sump tank. Both pump models include a ¼” N.P.T. female elbow and a plastic
check valve to prevent water from draining back into the pump after it has
turned off.
CAUTION: This pump has been evaluated for use with water only.
OPERATION
CONDENSATION REMOVAL
Attach the 3/8” barbed check valve to the ¼” N.P.T. elbow, and attach this
assembly to the pump’s discharge.
BE CAREFUL NOT TO OVER-TIGHTEN.
Place the pump in the sump tank or other suitable container as close as
possible to the air conditioning drip pan. Be sure the top of the drip pan is
at least 2” above the bottom of the pump.
Using 3/8” vinyl tubing, run the discharge up to the minimum distance
required, being sure not to exceed 90% of the “SHUT-OFF” height shown in the
performance chart.
If possible, slant the horizontal run down slightly to gain the benefit of
gravity.
If this pump is installed directly in the air conditioning drip pan, be sure
the pan is at least 2” deep and the pump is in the lowest part of the pan.
DE-WATERING
When the IPC13A is used for general pumping jobs such as draining flooded
areas, or whenever maximum flow is desired, do not use the check valve.
Instead attach ½” vinyl tubing directly to the discharge of the pump and
secure the connection with a hose clamp.
If the pump is to be used on a dirty or sandy surface, raise it slightly to
prevent dirt or debris from contacting the intake area. Using the pump
outdoors may require more frequent cleaning of the filter screen and impeller
area. See instructions for cleaning in MAINTENANCE. TYPICAL PERFORMANCE ±10%
PERFORMANCE
The performance of a pump is measured by its FLOW and its LIFT. In the following chart, the FLOW is expressed in Gallons Per Hour (GPH) and LIFT is expressed in Feet above the surface of the water. Measurements were taken at 115 volts using 3/8” vinyl tubing.
| TYPICAL PERFORMANCE ±10%
---|---
| GALLONS PER HOUR AT:
| 1′| 2′| 4′| 6′| 8′| 10′| SHUT OFF FEET
WITH CHECK VALVE| 77| 74| 65| 57| 45| 33| 12′
NO CHECK VALVE| 260| 252| 221| 198| 174| 111| 12′
“Shut-Off” is the maximum height the pump will lift water. At the “Shut-Off”
point there will be no water flow.
If less flow is desired, restrict the discharge of the pump. DO NOT restrict
the intake of the pump as damage to the motor and seal may occur.
FLOAT SWITCH INSTALLATION
The Safety Float Switch may be used to provide additional protection against flooded drip pans by shutting-off the system that is producing the water or condensation in the event the pan floods, the pump’s discharge becomes clogged, or other malfunction occurs. The switch may be wired to the thermostat circuit or it may be wired to any auxiliary alarm or other warning device.
The Safety Float Switch may be installed in the drip pan or it may be mounted
to the side of the molded plastic sump tank, as shown.
WARNING: Risk of electric shock, the remote Safety Float Switch is not
submersible and should be connected only to an N.E.C. Class II circuit of not
more than 30 volts.
MAINTENANCE
WARNING: Always disconnect from electrical outlet before servicing this
pump.
Beckett pumps have been designed to provide long, trouble-free service in
normal operating conditions. However, if the pump fails to operate, please
check the following:
- Is the pump getting electrical power? Check the circuit breaker and try another outlet to be sure.
- Has the intake screen become clogged?
- Are there any kinks or blockages in the discharge tubing?
- Is the impeller broken or jammed with debris?
- If the area around the impeller has become encrusted with minerals, it may be necessary to pry-off the impeller and gently scrape the area clean. After cleaning, apply a few crops of light oil where the impeller shaft enters the motor. Then, press the impeller back on using a penny to gage the spacing between the impeller and impeller back plate.
CAUTION: The cord of this pump contains a small “Breather Tube”.
This tube is necessary for the proper operation of the pressure switch.
Do not allow this tube to become blocked.
Before installing the pump, make sure to remove the breather tube cap.
WARNING: Do not remove the 4 screws that is holding the diaphragm cover in place. There are no serviceable parts in the switch mechanism, removing or loosening these screws may cause an electrical shock hazard.
LIMITED WARRANTY
Each Beckett Corporation (“Beckett”) product is warranted to be free from defects in material and workmanship for the applicable Warranty Period (herein so called) set forth below. The Warranty Period for each product commences on the date of purchase by the original purchaser. The Warranty Periods are as follows:
Product Type or Name
Warranty Period
Pump Models:
FR Series, DP800-1800, G Series, W Series …………2 Years
UL6500A; XL-6500A………………………. 2 Years
Other Pump Models……………………….. 1 Year
Pre-Formed Poly Ponds………………………. 15 Years
Waterfall Weir & Skimmer………………………… 5 Years
Liner Material:
35 mil PVC…………………………………..20 Years
40 mil EPDM…………………………………20 Years
20 mil PVC…………………………………..15 Years
UV9/UV13 Filter……………………………. 1 Year
All Other Beckett Products…………………90 Days
APPLICATION: The warranty covers only properly installed and maintained
Beckett products and is limited to application at normal temperature 32º F to
86º F, (0º C to 30º C) pumping fluids with a specific gravity up to 1.1 and
with a pH range of 5 to 9 (fresh water).
Other liquid applications and extreme temperature uses must be approved in
advance by Beckett. The warranty does not apply to or cover damages or defects
caused by external causes, including, but not limited to, improper or faulty
installation or unauthorized modification, lightning, electrical surges,
abuse, misuse or abnormal use or misapplication, including use in a manner
inconsistent with the product’s intended function. The purchaser is
responsible for determining the suitability of the product for its intended
use. If products are damaged in transit, a claim should be filed with the
carrier.
REMEDY: If there has been a failure to conform to the warranty, Beckett will,
at Beckett’s option, repair, replace or issue a credit or refund for the
particular nonconforming product or part. Repair, replacement, credit or
refund, at Beckett’s option, is the exclusive remedy in the event of a failure
to conform to the warranty. Warranty claims must be made within 3 months after
expiration of the applicable Warranty Period.
ADMINISTRATION: Warranty claims must be made by returning the nonconforming
Beckett product, freight prepaid, along with proof of purchase, to: Beckett
Corporation, Customer Service Dept., Irving, Texas, telephone
888-232-5388. Telephone authorization
from Beckett is required prior to returning nonconforming products or parts.
All products or parts returned will be inspected to determine cause of failure
before warranty is approved.
INSTALLATION, REMOVAL AND/OR SHIPPING CHARGES: The warranty does not cover any
costs associated with the installation, removal or shipping of products
subject to warranty claims.
DISCLAIMER AND LIMITATION: THE EXPRESS WARRANTY AND REMEDIES SET FORTH ABOVE
ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES, WHETHER ORAL
OR WRITTEN, EXPRESS OR IMPLIED. TO THE FULL EXTENT PERMITTED BY LAW, BECKETT
EXPRESSLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT
LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE. IF IMPLIED WARRANTIES CANNOT BE DISCLAIMED, ALL SUCH
IMPLIED WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS
WARRANTY.
BECKETT DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES EXPRESSLY SET FORTH IN
THIS WARRANTY. IN NO EVENT SHALL BECKETT BE LIABLE OR RESPONSIBLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES. BECKETT’S AGGREGATE LIABILITY UNDER THIS
WARRANTY OR WITH RESPECT TO ANY PRODUCT COVERED HEREBY, UNDER ANY LEGAL
THEORY, SHALL NOT EXCEED THE PURCHASE PRICE PAID FOR THE NONCONFORMING
PRODUCT. THE LIMITATIONS CONTAINED IN THIS PARAGRAPH SHALL NOT APPLY TO
INJURY TO THE PERSON.
Some States do not allow the exclusion or limitation of incidental or
consequential damages or exclusions or limitations on the duration of an
implied warranty, so the above limitations or exclusions may not apply to
you. This warranty gives you specific legal rights and you may also have other
rights that vary from State to State.
FOR YOUR RECORDS:
Date of Purchase __
Model Number
Name of Dealer
PLEASE KEEP RECEIPT IN CASE OF WARRANTY SERVICE.
BECKETT CORPORATION
Irving, Texas
www.beckettus.com
Toll Free: 1-888-232-5388
© 2019 BECKETT CORPORATION All Rights Reserved
SHOULD YOU ENCOUNTER ANY PROBLEMS WITH THIS PRODUCT,
CONTACT CUSTOMER CARE AT:
1-888-BECKETT
MONDAY THRU FRIDAY, BETWEEN THE HOURS OF 8:00 AM AND 5:00 PM CENTRAL STANDARD
TIME. WE ASK THAT YOU DO NOT RETURN THIS PRODUCT TO THE STORE BEFORE
CONTACTING US. YOU CAN ALSO CONTACT US AT OUR WEB SITE:
www.beckettus.com