JBC WS High Temperature Wire Stripper Control Unit Instruction Manual

June 11, 2024
JBC

JBC WS High Temperature Wire Stripper Control Unit

JBC WS High Temperature Wire Stripper Control

This manual corresponds to the following references:

WS-9UA (100V)
WS-1UA (120V)
WS-2UA (230V)

Packing List

The following items are included:

Packing List

High-Temperature
Wire Stripper
Control Unit …. 1 unit

Packing List

Power Cord ….. 1 unit
Ref. 0024092 (100V)
0023715 (120V)
0023714 (230V)

Packing List

Manual . …. 1 unit
Ref. 0030210

Features

Features

Connection with WS140

Connection with WS140

Connection with WS440

Connection with WS440

Control Process

Work Screen

Control Process

Work Mode

WS offers two different working modes. Switch the power on choose between Material Mode and Custom Mode by pressing the button.

  1. Material Mode
    Control Process
    Choose between the different materials by pressing the buttons and to choose between all different material options.
    Control Process

  2. Custom Mode
    Control Process
    To work on a customized mode, press and then the buttons and to select the power level.
    Control Process

Operation

Depending on where the tool is located, the soldering station switches between three different states: Work, Sleep and Hibernation. Depending on where the tool is located, the soldering station switches between three different states: Work, Sleep and Hibernation.
These states are available for JBCs High-Temperature Wire Strippers Tweezers WS140 and WS440.

  1. Work
    Operation
    When the wire stripper is lifted from the stand, the cartridges will heat up according to the selected configuration.
    Operation

  2. Sleep
    Operation
    When the wire stripper is in the stand, the power falls after a specified time.
    Operation

  3. Hibernation
    Operation
    After longer periods of inactivity, the power is cut off and the cartridges cool down to room temperature.
    Operation

Troubleshooting Troubleshooting

Station troubleshooting available on the product page at www.jbctools.com

Material Mode

WS incorporates predeterminated power levels and it also features a customized work mode. It allows you to work on wire insulations made of thermoplastics and thermostable materials such as Tefl on1 , Kapton2 , silicone, rubber, etc.

Options included:

  Insulation Material Symbol Power Level
Thermoplastics Polyvinyl Chloride PVC 6%
Polyethylene PE 7%
Nylon ¹ PA 10%
Kynar ² PVDF 16%
Tefzel ¹ ETFE 17%
Thermostable Teflon ¹ FEP 16%
PFA 21%
PTFE 40%
Ethylene Propylene Rubber EPM/EPR 44%
Silicone Rubber SI 51%
Kapton ¹ PI 90%
  1. Registered Trade Marks of DuPont
  2. Registered Trade Marks of Arkema

Accessories

Pedal P305

It can be used to activate/deactivate the Wire Stipper. Sleep and hibernation delay has to be set to 0 min.
Lift the wire stripper from the stand, press and hold the pedal to activate them and strip the wire. Once the pedal is relaesed the wire stripper enters in Hibernation. To reverse the pedal functionality flip the switch of the connection box.

Accessories

Flat Screw Driver*

To open or fi x the wire stripper srews use JBC Flat Screw Driver Ref. 0023511.

Accessories

Cartridge Extractor Pliers*

To manipulate the cartridges use JBC Cartridge Extractor Pliers Ref. PLR195. More Information at www.jbctools.com

Accessories

Removing Inserting and Positioning

Accessories| Accessories
Remove cartridges with JBC pliers.| Align cartridges with JBC pliers.

Metal Brush

For cleaning the tips if unwanted material is stuck there. Metal Brush Ref. 0022793.

Accessories

Maintenance

Maintenance

Before carrying out maintenance or storage, always allow the equipment to cool and unplug the stand from the station and the tool.

  • Clean the station screen with a glass cleaner or a damp cloth.
  • Use a damp cloth to clean the casing, the stand and the tool. Alcohol can only be used for cleaning the metal parts.
  • Periodically check that the metal parts of the tool and stand are clean so that the station can detect the tool status.
  • Maintain tip surface clean in order to ensure a correct stripped wire.
  • Periodically check all cables.
  • Replace a blown fuse as follows (see specification chart) :
  1. take out the fuse holder and remove the fuse. If necessary use a tool to lever it out.
    Maintenance

  2. Press the new fuse into the fuse holder and reinsert it in the station.
    Maintenance

  • Replace any defective or damaged pieces. Use original JBC spare parts only.
  • Repairs should only be performed by a JBC authorized technical service

Safety

It is imperative to follow safety guidelines to prevent electric shock, injury, fire or explosion.

Warning

  • Do not touch the blade or the metal parts around.
  • Do not allow the blade be close to flammable materials.
  • Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.
  • This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved.
  • Maintenance must not be carried out by children unless supervised.
  • Place the tool on the stand when is not in use.
  • Turn off the power when not in use, changing parts or storing.

Caution

  • Do not use the Wire Stripper for other applications than wire stripping.
  • Do not modify or customize the Wire Stripper.
  • Do not hit the blade against workbench to eliminate stripped insulation debris. This behavior would damage the blade.
  • Remove power from the tool by holding the plug, not the wires.
  • Be careful with the fumes produced when stripping. We recomend to use our fume extractor.

Specifications

WS
High-Temperature Wire Stripper Control Unit
Ref.: WSU-9A 100V 50/60Hz. Input Fuse: T1.6A. 5x20mm Output: 15V
Ref.: WSU-1A 120V 50/60Hz. Input Fuse: T1.25A. 5x20mm Output: 15V.
Ref.: WSU-2A 230V 50/60Hz. Input Fuse: T0.63A. 5x20mm Output: 15V.

  • Temperature Max : 800 ºC /1472 °F
  • Power: 75W
  • Ambient operating temp: 10 to 50 ºC /50 to 120 ºF
  • Connections: USB-B
  • Control Unit Dimensions / Weight: 180 x 94 x 106 mm / 2.2 kg (L x W x H) 7.1 x 3.7 x 4.2 in / 4.85 lb
  • Total Net Weight: 3.8 kg / 8.4 lb
  • Total Package Dimensions / Weight: 368 x 368 x 195 mm / 4.6 kg (L x W x H) 14.5 x 14.5 x 7.7 in /10.15 lb

Complies with CE standards.
ESD safe

Warranty

JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour.
Warranty does not cover product wear or misuse. In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.
Get 1 extra year JBC warranty by registering here: https://www.jbctools.com/productregistration/ within 30 days of purchase.

This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must be collected and returned to an authorized recycling facility

Symbols

www.jbctols.com

JBC Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

JBC User Manuals

Related Manuals